Mouse IL-11/Interleukin-11 ELISA Kit PicoKine®

IL-11 ELISA kit for Mouse

Mouse IL-11 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Il11 in cell culture supernatants, serum and plasma (heparin, EDTA, citrate). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays. Cited in 1 publication(s).

Product Info Summary

SKU: EK0420
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin, EDTA, citrate).

Product Name

Mouse IL-11/Interleukin-11 ELISA Kit PicoKine®

View all IL-11 ELISA kits

SKU/Catalog Number

EK0420

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse IL-11 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Il11 in cell culture supernatants, serum and plasma (heparin, EDTA, citrate). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse IL-11/Interleukin-11 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0420)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: E.coli; Immunogen sequence: P22-L199

Sensitivity

<10 pg/ml

Assay Range

31.2 pg/ml - 2,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK0420 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0420 is reactive to Il11 in Mouse samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin, EDTA, citrate).

Application Guarantee

EK0420 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of IL-11

Interleukin 11 (IL-11) is a protein that in humans is encoded by the IL11 gene. The protein encoded by this gene is a member of the gp130 family of cytokines. This gene is mapped to 19q13.42. It is a key regulator of multiple events in hematopoiesis, most notably the stimulation of megakaryocyte maturation. IL-11 has been demonstrated to improve platelet recovery after chemotherapy-induced thrombocytopenia, induce acute phase proteins, modulate antigen-antibody responses, participate in the regulation of bone cell proliferation and differentiation and could be use as a therapeutic for osteoporosis. What's more, IL-11 can stimulate the growth of certain lymphocytes and it has functions in many other tissues, including the brain, gut, testis and bone. In transgenic mice, overexpression of the human IL11 gene resulted in the stimulation of bone formation to increase cortical thickness and strength of long bones.

Kit Components

Catalog Number Description Quantity
EK0420-CAP Anti-Mouse Il11 Pre-coated 96-well strip microplate 1
EK0420-ST Mouse Il11 Standard 2 vials, 10 ng/tube
EK0420-DA Mouse Il11 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)031.262.512525050010002000
O.D.0.0420.0920.1400.2160.4460.7711.3352.030

Data Example Images

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse IL-11/Interleukin-11 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)6430588263276909
Standard deviation4.8616.7762.624.9116.8370.9
CV (%)7.6%5.5%7.1%7.8%6.1%7.8%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of IL-11 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 164636462630.821.3%
Sample 230531528428429713.474.5%
Sample 388299296389893345.294.8%
*number of samples for each test n=16.

Gene/Protein Information For Il11 (Source: Uniprot.Org, NCBI)

Gene Name

Il11

Full Name

Interleukin-11

Weight

21522 MW

Superfamily

IL-6 superfamily

Alternative Names

Interleukin-11;IL-11;Il11; IL11 AGIF, IL-11 interleukin 11 interleukin-11|adipogenesis inhibitory factor|oprelvekin

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on Il11, check out the Il11 Infographic

Il11 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for Il11: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK0420 has been cited in 1 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

The gp130 Cytokine Interleukin‐11 Regulates Engraftment of Vav1–/– Hematopoietic Stem and Progenitor Cells in Lethally Irradiated Recipients

Have you used Mouse IL-11/Interleukin-11 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Mouse IL-11/Interleukin-11 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

7 Customer Q&As for Mouse IL-11/Interleukin-11 ELISA Kit PicoKine®

Question

Does EK0420 contain native human biological materials?

Verified customer

Asked: 2021-11-10

Answer

The Mouse IL-11/Interleukin-11 ELISA Kit PicoKine® (EK0420) doesn't contain native human biological materials.

Boster Scientific Support

Answered: 2021-11-11

Question

Q: how to analyze ELISA data? I have obtained IL-11 level in plasma.

Verified Customer

Verified customer

Asked: 2020-10-05

Answer

A: we recommend you this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2020-10-05

Question

Q: we need your suggestion regarding the dilution ratio of serum samples for detection of IL-11 in Mouse plasma? I am trying to measure a a number of analytes and it requires 100ul of diluted samples for each well. We have low serum quantitys so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2020-09-10

Answer

A: having little idea about the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the IL-11 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2020-09-10

Question

Q: Can IL-11 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2019-05-27

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2019-05-27

Question

Q: how are cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2019-05-14

Answer

A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate can be found in the product insert. Components in lysate and lysis buffer can change immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2019-05-14

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2018-12-16

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2018-12-16

Question

Q: What is the optimal O.D. value for IL-11 ELISA kit? I performed your IL-11 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain IL-11 even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2018-11-12

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. what you should focus on is whether your sample O.D. values are statistically significantly higher than your blank values. regarding your protocol, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this IL-11 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of IL-11 that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2018-11-12

$499
In stock, 1 left.

Order within 77 hours and 44 minutes to receive by Tue Nov 19

Get A Quote
In stock
Order Product
EK0420
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.