Product Info Summary
SKU: | EK0576 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Mouse |
Application: | ELISA |
Sample Types: | cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). |
Product info
Product Name
Mouse CCL24/Eotaxin-2 ELISA Kit PicoKine®
View all CCL24/Eotaxin-2/MPIF-2 ELISA kits
SKU/Catalog Number
EK0576
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Mouse CCL24/Eotaxin-2 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Ccl24 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Mouse CCL24/Eotaxin-2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0576)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: E.coli; Immunogen sequence: V27-V119
Sensitivity
<10 pg/ml
Assay Range
15.6 pg/ml - 1,000 pg/ml
Standard Dilution Instructions
See datasheet of EK0576 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0576 is reactive to Ccl24 in Mouse samples
Validated Sample Types
cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).
Application Guarantee
EK0576 is guaranteed for ELISA in Mouse by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of CCL24/Eotaxin-2/MPIF-2
Chemokine (C-C motif) ligand 24 (CCL24) also known as myeloid progenitor inhibitory factor 2 (MPIF-2) or eosinophil chemotactic protein 2 (eotaxin-2) is a protein that in humans is encoded by the CCL24 gene.1 By use of PCR analysis of somatic cell hybrid DNAs, radiation hybrid mapping, and a chromosome 7-specific YAC library, mapped the SCYA24 gene to chromosome 7q11.23.2 CCL24 is a small cytokine belonging to the CC chemokine family. CCL24 interacts with chemokine receptor CCR3 to induce chemotaxis in eosinophils.3 This chemokine is also strongly chemotactic for resting T lymphocytes and slightly chemotactic for neutrophils.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK0576-CAP | Anti-Mouse Ccl24 Pre-coated 96-well strip microplate | 1 |
EK0576-ST | Mouse Ccl24 Standard | 2 vials, 10 ng/tube |
EK0576-DA | Mouse Ccl24 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 15.6 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 |
O.D. | 0.081 | 0.163 | 0.251 | 0.405 | 0.696 | 1.219 | 1.891 | 2.345 |
Data Example Images
Click image to see more details
Mouse CCL24/Eotaxin-2 PicoKine ELISA Kit standard curve
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Mouse CCL24/Eotaxin-2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 37 | 220 | 498 | 37 | 218 | 503 |
Standard deviation | 2.55 | 10.12 | 35.85 | 2.55 | 12.42 | 38.73 |
CV (%) | 6.9% | 4.6% | 7.2% | 6.9% | 5.7% | 7.7% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of CCL24/Eotaxin-2/MPIF-2 in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 37 | 38 | 39 | 39 | 38 | 0.82 | 2.1% |
Sample 2 | 220 | 203 | 230 | 223 | 219 | 9.92 | 4.5% |
Sample 3 | 498 | 423 | 499 | 448 | 467 | 32.71 | 7% |
Protein Target Info & Infographic
Gene/Protein Information For Ccl24 (Source: Uniprot.Org, NCBI)
Gene Name
Ccl24
Full Name
C-C motif chemokine 24
Weight
12871 MW
Superfamily
intercrine beta (chemokine CC) family
Alternative Names
C-C motif chemokine 24;Eosinophil chemotactic protein 2;Eotaxin-2;Small-inducible cytokine A24;Ccl24;Scya24; CCL24 Ckb-6, MPIF-2, MPIF2, SCYA24 C-C motif chemokine ligand 24 C-C motif chemokine 24|CK-beta-6|chemokine (C-C motif) ligand 24|eosinophil chemotactic protein 2|eotaxin-2|myeloid progenitor inhibitory factor 2|small inducible cytokine subfamily A (Cys-Cys), member 24|small-inducible cytokine A24
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on Ccl24, check out the Ccl24 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for Ccl24: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Mouse CCL24/Eotaxin-2 ELISA Kit PicoKine® (EK0576)
Hello CJ!
No publications found for EK0576
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Mouse CCL24/Eotaxin-2 ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Mouse CCL24/Eotaxin-2 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
8 Customer Q&As for Mouse CCL24/Eotaxin-2 ELISA Kit PicoKine®
Question
Q: is it okay to use citrate plasma as samples in Mouse CCL24 Picokine® ELISA Kit (Catalog # EK0576)?
P. Dhar
Verified customer
Asked: 2020-06-03
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can bind metal ions from the functional domain of CCL24 causing disruption of its protein structure. CCL24 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the CCL24 ELISA, treating samples with various anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2020-06-03
Question
Q: Can CCL24 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
V. Green
Verified customer
Asked: 2020-04-28
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2020-04-28
Question
Q: how to proceed with the analysis of ELISA data? I measured CCL24 level in cell lysates.
Verified Customer
Verified customer
Asked: 2019-09-02
Answer
A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online
Boster Scientific Support
Answered: 2019-09-02
Question
Q: which procedure should I follow in order to thaw whole blood sample for CCL24 ELISA after freezing?
L. Evans
Verified customer
Asked: 2019-02-09
Answer
A: we do not recommend freezing and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test CCL24 for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.
Boster Scientific Support
Answered: 2019-02-09
Question
Q: how much samples can be assayed in a Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2019-01-04
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2019-01-04
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
Verified Customer
Verified customer
Asked: 2017-07-08
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2017-07-08
Question
Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for measuring CCL24 using the EK0576 Mouse CCL24 Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2017-02-11
Answer
A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. avoid repeat freeze-thaw cycles with the stored samples to avoid protein degradation.
Boster Scientific Support
Answered: 2017-02-11
Question
Q: can you tell me how to prepare cell lysates prepared for use in Picokine® ELISA kits?
Verified Customer
Verified customer
Asked: 2014-12-06
Answer
A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate can be found in the product insert. Components in lysate and lysis buffer can affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2014-12-06