Product Info Summary
SKU: | EK1206 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Mouse |
Application: | ELISA |
Sample Types: | cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). |
Product info
Product Name
Mouse TSLP ELISA Kit PicoKine®
SKU/Catalog Number
EK1206
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Mouse TSLP ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Tslp in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Mouse TSLP ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1206)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: Y20-E140
Sensitivity
<10 pg/ml
Assay Range
15.6 pg/ml - 1,000 pg/ml
Standard Dilution Instructions
See datasheet of EK1206 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK1206 is reactive to Tslp in Mouse samples
Validated Sample Types
cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).
Application Guarantee
EK1206 is guaranteed for ELISA in Mouse by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of Tslp
Thymic stromal lymphopoietin, also called TSLP, is a protein belonging to the cytokine family. This gene is mapped to 5q22.1. It encodes a hemopoietic cytokine proposed to signal through a heterodimeric receptor complex composed of the thymic stromal lymphopoietin receptor and the IL-7R alpha chain. It mainly impacts myeloid cells and induces the release of T cell-attracting chemokines from monocytes and enhances the maturation of CD11c (+) dendritic cells. The protein promotes T helper type 2 (TH2) cell responses that are associated with immunity in various inflammatory diseases, including asthma, allergic inflammation and chronic obstructive pulmonary disease. The protein is therefore considered a potential therapeutic target for the treatment of such diseases.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK1206-CAP | Anti-Mouse Tslp Pre-coated 96-well strip microplate | 1 |
EK1206-ST | Mouse Tslp Standard | 2 vials, 10 ng/tube |
EK1206-DA | Mouse Tslp Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 15.6 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 |
O.D. | 0.029 | 0.098 | 0.157 | 0.298 | 0.574 | 1.094 | 1.689 | 2.267 |
Data Example Images
Click image to see more details
Mouse TSLP PicoKine ELISA Kit standard curve
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Mouse TSLP ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 34 | 252 | 469 | 33 | 246 | 427 |
Standard deviation | 1.8 | 15.12 | 36.58 | 1.74 | 15.25 | 38.43 |
CV (%) | 5.3% | 6% | 7.8% | 5.3% | 6.2% | 9% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of Tslp in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 34 | 32 | 33 | 31 | 32 | 1.11 | 3.4% |
Sample 2 | 252 | 250 | 232 | 230 | 241 | 10.04 | 4.1% |
Sample 3 | 469 | 440 | 476 | 463 | 462 | 13.5 | 2.9% |
Protein Target Info & Infographic
Gene/Protein Information For Tslp (Source: Uniprot.Org, NCBI)
Gene Name
Tslp
Full Name
Thymic stromal lymphopoietin
Weight
16152 MW
Alternative Names
Thymic stromal lymphopoietin;Thymic stroma-derived lymphopoietin;Tslp; Tslp|thymic stromal lymphopoietin|thymic stromal lymphopoietin|thymic stroma-derived lymphopoietin
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on Tslp, check out the Tslp Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for Tslp: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Mouse TSLP ELISA Kit PicoKine® (EK1206)
Hello CJ!
No publications found for EK1206
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Mouse TSLP ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Mouse TSLP ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
7 Customer Q&As for Mouse TSLP ELISA Kit PicoKine®
Question
Q: how much samples can be assayed in a Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2020-09-22
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2020-09-22
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
B. Davis
Verified customer
Asked: 2020-01-07
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions
Boster Scientific Support
Answered: 2020-01-07
Question
Q: which procedure should I follow in order to thaw whole blood sample for Tslp ELISA after freezing?
C. Kulkarni
Verified customer
Asked: 2019-08-06
Answer
A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test Tslp for a later time, you should let the blood clot in glass tubes and collect the serum to freeze for later use.
Boster Scientific Support
Answered: 2019-08-06
Question
Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for measuring Tslp using the EK1206 Mouse Tslp Picokine® ELISA Kit?
G. Tiwari
Verified customer
Asked: 2017-06-25
Answer
A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample immediately after collection when possible, or aliquot into single use volumes and store samples frozen. avoid repeat freeze-thaw cycles with the stored samples to limit protein degradation.
Boster Scientific Support
Answered: 2017-06-25
Question
Q: What is the optimal O.D. value for Tslp ELISA kit? I performed your Tslp ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain Tslp even though the O.D. values are not very high?
Verified Customer
Verified customer
Asked: 2017-03-02
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in the example mentioned, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this Tslp ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of Tslp that can be declared/interpreted as positive by the above standard is 10pg/ml.
Boster Scientific Support
Answered: 2017-03-02
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
Z. Parker
Verified customer
Asked: 2016-05-14
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is needed for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2016-05-14
Question
Q: if the enzyme conjugated Tslp antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the Tslp antigen?
H. Dhawan
Verified customer
Asked: 2014-02-26
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2014-02-26