Product Info Summary
SKU: | EK1946 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Human |
Application: | ELISA |
Sample Types: | cell culture supernatants, serum and plasma (heparin, EDTA). |
Product info
Product Name
Human Neudesin ELISA Kit PicoKine®
SKU/Catalog Number
EK1946
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human Neudesin ELISA Kit PicoKine® (96 Tests). Quantitate Human NENF in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 15pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human Neudesin ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1946)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: E.coli; Immunogen sequence: G32-F172
Sensitivity
<15 pg/ml
Assay Range
93.6 pg/ml - 6,000 pg/ml
Standard Dilution Instructions
See datasheet of EK1946 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK1946 is reactive to NENF in Human samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin, EDTA).
Application Guarantee
EK1946 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of Neudesin
This gene encodes a neurotrophic factor that may play a role in neuron differentiation and development. A pseudogene of this gene is found on chromosome 12. Alternate splicing of this gene results in multiple transcript variants. It is mapped to 1q32.3.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK1946-CAP | Anti-Human NENF Pre-coated 96-well strip microplate | 1 |
EK1946-ST | Human NENF Standard | 2 vials, 10 ng/tube |
EK1946-DA | Human NENF Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 93.6 | 187 | 375 | 750 | 1500 | 3000 | 6000 |
O.D. | 0.058 | 0.119 | 0.181 | 0.257 | 0.482 | 0.910 | 1.522 | 2.263 |
Data Example Images
Click image to see more details
Human Neudesin PicoKine ELISA Kitstandard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect Neudesin, Dilution ratio of 1:1, concentration in serum and plasma is around 1000 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human Neudesin ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 124 | 715 | 2078 | 159 | 739 | 2238 |
Standard deviation | 7.69 | 32.18 | 118.45 | 7.79 | 42.86 | 140.99 |
CV (%) | 6.2% | 4.5% | 5.7% | 4.9% | 5.8% | 6.3% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of Neudesin in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 124 | 126 | 128 | 129 | 126 | 1.92 | 1.5% |
Sample 2 | 715 | 739 | 809 | 714 | 744 | 38.69 | 5.2% |
Sample 3 | 2078 | 2149 | 2030 | 2027 | 2071 | 49.37 | 2.3% |
Protein Target Info & Infographic
Gene/Protein Information For NENF (Source: Uniprot.Org, NCBI)
Gene Name
NENF
Full Name
Neudesin
Weight
18.856kDa
Superfamily
cytochrome b5 family
Alternative Names
Neudesin; Cell immortalization-related protein 2; Neuron-derived neurotrophic factor; Protein GIG47; Secreted protein of unknown function; SPUF protein; NENF; CIR2; SPUF NENF CIR2, SCIRP10, SPUF neudesin neurotrophic factor neudesin|SCIRP10-related protein|Spinal cord injury related protein 10|cell growth-inhibiting protein 47|cell immortalization-related protein 2|neuron-derived neurotrophic factor|secreted protein of unknown function
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on NENF, check out the NENF Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for NENF: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Human Neudesin ELISA Kit PicoKine® (EK1946)
Hello CJ!
No publications found for EK1946
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Human Neudesin ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Human Neudesin ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
10 Customer Q&As for Human Neudesin ELISA Kit PicoKine®
Question
Q: Can Neudesin ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
Verified Customer
Verified customer
Asked: 2020-07-09
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is a must. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2020-07-09
Question
Q: which procedure should I follow in order to thaw whole blood sample for Neudesin ELISA after freezing?
Verified Customer
Verified customer
Asked: 2020-04-24
Answer
A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test Neudesin for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.
Boster Scientific Support
Answered: 2020-04-24
Question
Q: how many samples can be assayed in a Picokine® ELISA Kit?
H. Sunder
Verified customer
Asked: 2019-10-30
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2019-10-30
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
Verified Customer
Verified customer
Asked: 2019-08-25
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is a must for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2019-08-25
Question
Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for measuring Neudesin using the EK1946 Human Neudesin Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2019-07-17
Answer
A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may affect the stabilityof samples. It is recommend to assay sample on-stat collection when possible, or aliquot into single use volumes and store samples frozen. avoid repeat freeze-thaw cycles with the stored samples to avoid protein degradation.
Boster Scientific Support
Answered: 2019-07-17
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
Verified Customer
Verified customer
Asked: 2019-04-21
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions
Boster Scientific Support
Answered: 2019-04-21
Question
Q: how are cell lysates prepared for use in Picokine® ELISA kits?
W. Zhou
Verified customer
Asked: 2018-12-15
Answer
A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer may affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2018-12-15
Question
Q: can you suggest the dilution ratio of serum samples for detection of Neudesin in Human plasma? I am trying to measure a multiple analytes and it requires 100ul of diluted samples for each well. We have limited sample volumes so we like to dilute as much as possible.
Verified Customer
Verified customer
Asked: 2018-05-27
Answer
A: without knowing the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the Neudesin ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2018-05-27
Question
Q: can I use citrate plasma as samples in Human Neudesin Picokine® ELISA Kit (Catalog # EK1946)?
Verified Customer
Verified customer
Asked: 2017-10-30
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can attach metal ions from the functional domain of Neudesin causing degradation of its protein structure. Neudesin may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes required for detection and block the antigen antibody reaction. We have tested the Neudesin ELISA, treating samples with various anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2017-10-30
Question
Q: how to proceed with the analysis of ELISA data? I measured Neudesin level in plasma.
Verified Customer
Verified customer
Asked: 2017-06-18
Answer
A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online
Boster Scientific Support
Answered: 2017-06-18