SKU: | EK0459 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Human |
Application: | ELISA |
Sample Types: | cell culture supernatants, serum and plasma (heparin). |
Product info
Product Name
Human MMP-2 ELISA Kit PicoKine®
SKU/Catalog Number
EK0459
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human MMP-2 ELISA Kit PicoKine® (96 Tests). Quantitate Human MMP2 in cell culture supernatants, serum and plasma (heparin). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human MMP-2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0459)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: A30-C660
Sensitivity
<10 pg/ml
Assay Range
625 pg/ml - 40,000 pg/ml
Standard Dilution Instructions
See datasheet of EK0459 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0459 is reactive to MMP2 in Human samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin).
Application Guarantee
EK0459 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of MMP-2
Type IV collagenase, 72-kD, is officially designated matrix metalloproteinase-2 (MMP2). It is also known as gelatinase, 72-kD. MMP-2 plays an essential role in angiogenesis and arteriogenesis, two processes critical to restoration of tissue perfusion after ischemia. MMP-2 expression is increased in tissue ischemia, but the responsible mechanisms remain unknown. Matrix metalloproteinases (MMPs) catalyze extracellular matrix degradation. Control of their activity is a promising target for therapy of diseases characterized by abnormal connective tissue turnover. MMPs are expressed as latent proenzymes that are activated by proteolytic cleavage that triggers a conformational change in the propeptide (cysteine switch). The structure of proMMP-2 reveals how the propeptide shields the catalytic cleft and that the cysteine switch may operate through cleavage of loops essential for propeptide stability. The gene is localized to 16q21 using somatic cell hybrids and in situ hybridization. The standard product used in this kit is recombinant human MMP-2, consisting of 631 amino acids with the molecular mass of 71KDa. The detected MMP-2 includes zymogen and active enzyme.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK0459-CAP | Anti-Human MMP2 Pre-coated 96-well strip microplate | 1 |
EK0459-ST | Human MMP2 Standard | 2 vials, 40 ng/tube |
EK0459-DA | Human MMP2 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 625 | 1250 | 2500 | 5000 | 10000 | 20000 | 40000 |
O.D. | 0.033 | 0.055 | 0.112 | 0.192 | 0.313 | 0.538 | 1.041 | 1.812 |
Data Example Images
Click image to see more details
Human MMP-2 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect MMP-2, Dilution ratio of 1:10, concentration in serum and plasma is 20-50 ng/ml..
Some articles we found to cite concentrations of MMP-2 in samples: 17239302 (Pubmed IDs).
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human MMP-2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 1326 | 3925 | 14099 | 1253 | 3970 | 14093 |
Standard deviation | 80.88 | 282.6 | 690.85 | 76.43 | 349.36 | 690.55 |
CV (%) | 6.1% | 7.2% | 4.9% | 6.1% | 8.8% | 4.9% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of MMP-2 in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 1326 | 1365 | 1368 | 1233 | 1323 | 54.53 | 4.1% |
Sample 2 | 3925 | 3610 | 3426 | 3883 | 3711 | 204.2 | 5.5% |
Sample 3 | 14099 | 16330 | 14083 | 16849 | 15340 | 1262.66 | 8.2% |
Protein Target Info & Infographic
Gene/Protein Information For MMP2 (Source: Uniprot.Org, NCBI)
Gene Name
MMP2
Full Name
72 kDa type IV collagenase
Weight
73882 MW
Superfamily
peptidase M10A family
Alternative Names
72 kDa type IV collagenase;3.4.24.24;72 kDa gelatinase;Gelatinase A;Matrix metalloproteinase-2;MMP-2;TBE-1;PEX;MMP2;CLG4A; MMP2 CLG4, CLG4A, MMP-2, MMP-II, MONA, TBE-1 matrix metallopeptidase 2 72 kDa type IV collagenase|collagenase type IV-A|matrix metallopeptidase 2 (gelatinase A, 72kDa gelatinase, 72kDa type IV collagenase)|matrix metalloproteinase-2|matrix metalloproteinase-II|neutrophil gelatinase
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on MMP2, check out the MMP2 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for MMP2: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Human MMP-2 ELISA Kit PicoKine® (EK0459)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Human MMP-2 ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Human MMP-2 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
8 Customer Q&As for Human MMP-2 ELISA Kit PicoKine®
Question
Would EK0459 be suitable to measure pro-MMP2 in human Serum and EDTA-plasma samples?
Verified customer
Asked: 2021-01-25
Answer
EDTA-plasma is not recommended to be used in this assay due to its chelating property. The Human MMP-2 ELISA Kit PicoKine™ (EK0459) detects total MMP2 including pro and mature MMP-2 and it is not specific to detect pro-MMP2 only.
Boster Scientific Support
Answered: 2021-01-26
Question
Do these ELISA kits (Human MMP-2 & Human MMP-3) use the same sample diluent? What kind of chemicals are present in this diluent?
Verified Customer
Verified customer
Asked: 2019-09-11
Answer
Yes. The diluent contains NaCl, Tris, BSA and preservative.
Boster Scientific Support
Answered: 2019-09-11
Question
Q: how to analyze ELISA data? I measured MMP-2 level in plasma.
A. Kapoor
Verified customer
Asked: 2019-02-12
Answer
A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online
Boster Scientific Support
Answered: 2019-02-12
Question
Q: how much samples can be assayed in a Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2018-04-06
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may depends upon the kit used so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2018-04-06
Question
Q: Can MMP-2 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
Verified Customer
Verified customer
Asked: 2016-08-13
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is needed. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2016-08-13
Question
Q: What is the optimal O.D. value for MMP-2 ELISA kit? I performed your MMP-2 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain MMP-2 even though the O.D. values are not very high?
Verified Customer
Verified customer
Asked: 2015-09-02
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this MMP-2 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of MMP-2 that can be declared/interpreted as positive by the above standard is 10pg/ml.
Boster Scientific Support
Answered: 2015-09-02
Question
Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for measuring MMP-2 using the EK0459 Human MMP-2 Picokine® ELISA Kit?
H. Martin
Verified customer
Asked: 2015-08-23
Answer
A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample on priority basis collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples to limit protein degradation.
Boster Scientific Support
Answered: 2015-08-23
Question
Does EK0459 detect total MMP-2 (both pro & active forms)?
Verified Customer
Verified customer
Asked: 2015-07-23
Answer
EK0459 is able to detect total MMP-2 (pro &
Boster Scientific Support
Answered: 2015-07-23