Mouse IL-31/Interleukin-31 ELISA Kit PicoKine®

IL-31 ELISA kit for Mouse

Mouse IL-31 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Il31 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays. Cited in 2 publication(s).

Product Info Summary

SKU: EK1100
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Mouse IL-31/Interleukin-31 ELISA Kit PicoKine®

View all IL-31 ELISA kits

SKU/Catalog Number

EK1100

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse IL-31 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Il31 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse IL-31/Interleukin-31 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1100)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: E.coli; Immunogen sequence: T24-C163

Sensitivity

<10 pg/ml

Assay Range

62.5 pg/ml - 4,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK1100 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1100 is reactive to Il31 in Mouse samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK1100 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of IL-31

Interleukin-31, also known as IL-31 is a protein that in humans is encoded by the IL31 gene. The IL31 gene is mapped to chromosome 12q24.31 and the mouse gene maps to a syntenic region on chromosome 5. IL31, which is made principally by activated Th2-type T cells, interacts with a heterodimeric receptor consisting of IL31RA and OSMR that is constitutively expressed on epithelial cells and keratinocytes. IL31 may be involved in the promotion of allergic skin disorders and in regulating other allergic diseases, such as asthma.

Kit Components

Catalog Number Description Quantity
EK1100-CAP Anti-Mouse Il31 Pre-coated 96-well strip microplate 1
EK1100-ST Mouse Il31 Standard 2 vials, 10 ng/tube
EK1100-DA Mouse Il31 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)062.5125250500100020004000
O.D.0.0400.1080.1570.2580.4590.7841.2751.988

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect IL-31, Dilution ratio of 1:1, concentration in serum and plasma is less than the lowest standard, 62.5 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse IL-31/Interleukin-31 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)20979012702127191315
Standard deviation9.8260.8355.8811.6658.9568.38
CV (%)4.7%7.7%4.4%5.5%8.2%5.2%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of IL-31 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 120921318917619615.037.6%
Sample 279081071479877837.624.8%
Sample 31270129013151320129820.111.5%
*number of samples for each test n=16.

Gene/Protein Information For Il31 (Source: Uniprot.Org, NCBI)

Gene Name

Il31

Full Name

Interleukin-31

Weight

18120 MW

Alternative Names

Interleukin-31;IL-31;Il31; Il31|1700013B14Rik|interleukin 31|interleukin-31|IL-31

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on Il31, check out the Il31 Infographic

Il31 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for Il31: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK1100 has been cited in 2 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

Nalbuphine, a kappa opioid receptor agonist and mu opioid receptor antagonist attenuates pruritus, decreases IL-31, and increases IL-10 in mice with contact dermatitis

Nalbuphine, a kappa opioid receptor agonist and mu opioid receptor antagonist attenuates pruritus, decreases IL-31, and increases IL-10 in mice with contact dermatitis

Have you used Mouse IL-31/Interleukin-31 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Mouse IL-31/Interleukin-31 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

6 Customer Q&As for Mouse IL-31/Interleukin-31 ELISA Kit PicoKine®

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2019-06-14

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2019-06-14

Question

Q: Can IL-31 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2018-12-31

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please view the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2018-12-31

Question

Q: can you suggest the dilution ratio of serum samples for detection of IL-31 in Mouse serum? I am trying to measure a a number of analytes and it requires 100ul of diluted samples for each well. We have low serum volumes so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2018-10-29

Answer

A: unable to know the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the IL-31 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2018-10-29

Question

Q: What is the optimal O.D. value for IL-31 ELISA kit? I performed your IL-31 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain IL-31 even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2018-07-26

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. a point of focus should be is whether your sample O.D. values are statistically significantly higher than your blank values. in the example mentioned, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this IL-31 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of IL-31 that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2018-07-26

Question

Q: how to analyze ELISA data? I have performed IL-31 level in serum.

Verified Customer

Verified customer

Asked: 2018-02-01

Answer

A: we recommend you this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2018-02-01

Question

Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for measurement IL-31 using the EK1100 Mouse IL-31 Picokine® ELISA Kit?

S. Miller

Verified customer

Asked: 2014-02-16

Answer

A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample on-stat collection when possible, or aliquot into single use volumes and store samples frozen. avoid repeat freeze-thaw cycles with the stored samples to limit protein degradation.

Boster Scientific Support

Answered: 2014-02-16

$499
In stock, 1 left.

Order within 0 hours and -24 minutes to receive by Thu Nov 14

Get A Quote
In stock
Order Product
EK1100
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.