Mouse CD5L/CT-2 ELISA Kit PicoKine®

CD5L ELISA kit for Mouse

Mouse CD5L / CT 2 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Cd5l in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Product Info Summary

SKU: EK1414
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Mouse CD5L/CT-2 ELISA Kit PicoKine®

View all CD5L ELISA kits

SKU/Catalog Number

EK1414

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse CD5L / CT 2 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Cd5l in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse CD5L/CT-2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1414)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: NS0; Immunogen sequence: E22-V352

Sensitivity

<10 pg/ml

Assay Range

156 pg/ml - 10,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK1414 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1414 is reactive to Cd5l in Mouse samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK1414 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of CD5L

CD5 antigen-like, also known as Sp alpha and AIM, is a protein that in humans is encoded by the CD5L gene. It is mapped to 1q21-q23 by fluorescence in situ hybridization. It is found that Aim expression is induced in mouse macrophages in response to loading with highly oxidized low density lipoprotein (oxLDL), and that Aim is expressed in foam cells within atherosclerotic lesions. Both the expression of Aim in lesions and its induction by oxLDL require Lxr /Rxr heterodimers. Aim-null macrophages are highly susceptible to oxLDL-induced apoptosis in vitro and undergo accelerated apoptosis in atherosclerotic lesions in vivo. Double knockout of Aim and Ldlr reduce atherosclerotic lesions. Therefore, it is concluded that AIM expression protects macrophages from apoptosis within atherosclerotic lesions, promoting early lesion development.

Kit Components

Catalog Number Description Quantity
EK1414-CAP Anti-Mouse Cd5l Pre-coated 96-well strip microplate 1
EK1414-ST Mouse Cd5l Standard 2 vials, 10 ng/tube
EK1414-DA Mouse Cd5l Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015631262512502500500010,000
O.D.0.0300.1150.2100.3450.5570.9001.3841.909

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect CD5L, Dilution ratio of 1:400, concentration in serum and plasma is 280-600 ng/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse CD5L/CT-2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)2011789494020719354821
Standard deviation13.26110.91375.4417.38131.58414.6
CV (%)6.6%6.2%7.6%8.4%6.8%8.6%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of CD5L in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 120123623222222213.556.1%
Sample 21789179518751980185977.284.1%
Sample 349404445482548344761187.963.9%
*number of samples for each test n=16.

Gene/Protein Information For Cd5l (Source: Uniprot.Org, NCBI)

Gene Name

Cd5l

Full Name

CD5 antigen-like

Weight

38863 MW

Alternative Names

CD5 antigen-like;Apoptosis inhibitor expressed by macrophages ;mAIM ;Apoptosis inhibitory 6;SP-alpha ;Cd5l;Aim , Api6; CD5L AIM, API6, CT-2, PRO229, SP-ALPHA, Spalpha, hAIM CD5 molecule like CD5 -like|CD5 -like (scavenger receptor cysteine rich family)|apoptosis inhibitor 6|apoptosis inhibitor expressed by macrophages|apoptosis inhibitor of macrophage|igM-associated peptide

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on Cd5l, check out the Cd5l Infographic

Cd5l infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for Cd5l: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK1414

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Mouse CD5L/CT-2 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Mouse CD5L/CT-2 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

7 Customer Q&As for Mouse CD5L/CT-2 ELISA Kit PicoKine®

Question

What is the range of CD5L values observed in the Normal Mouse Serum samples you've tested?

Verified customer

Asked: 2020-11-30

Answer

For the Mouse CD5L / CT 2 ELISA Kit PicoKine™ (EK1414), the range of CD5L values observed in the Normal Mouse Serum samples we've tested is 200-600ng/ml.

Boster Scientific Support

Answered: 2020-12-04

Question

Q: how to proceed with the analysis of ELISA data? I have performed CD5L level in serum.

Verified Customer

Verified customer

Asked: 2020-11-23

Answer

A: we recommend you this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. we also provide a convenient online tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2020-11-23

Question

Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2020-11-16

Answer

A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate can be found in the product insert. Components in lysate and lysis buffer can affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2020-11-16

Question

Q: we need your suggestion regarding the dilution ratio of serum samples for detection of CD5L in Mouse serum? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have limited sample quantitys so we like to dilute as much as possible.

J. Kulkarni

Verified customer

Asked: 2019-11-28

Answer

A: without knowing the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CD5L ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2019-11-28

Question

Q: is it okay to use citrate plasma as samples in Mouse CD5L Picokine® ELISA Kit (Catalog # EK1414)?

Verified Customer

Verified customer

Asked: 2018-12-27

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can bind metal ions from the functional domain of CD5L causing degradation of its protein structure. CD5L may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes needed for detection and block the antigen antibody reaction. We have tested the CD5L ELISA, treating samples with different anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2018-12-27

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

J. Tiwari

Verified customer

Asked: 2017-03-27

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may depends upon the kit used so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2017-03-27

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

W. Wu

Verified customer

Asked: 2016-08-08

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2016-08-08

$499
In stock, 2 left.

Order within -6 hours and -14 minutes to receive by Mon Nov 25

Get A Quote
In stock
Order Product
EK1414
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.

No publications found

No publications have been found for this product