Mouse CCL7/MCP-3 ELISA Kit PicoKine®

CCL7/MCP-3/MARC ELISA kit for Mouse

Mouse CCL7/MCP-3 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Ccl7 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 1pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Product Info Summary

SKU: EK0683
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Mouse CCL7/MCP-3 ELISA Kit PicoKine®

View all CCL7/MCP-3/MARC ELISA kits

SKU/Catalog Number

EK0683

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse CCL7/MCP-3 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Ccl7 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 1pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse CCL7/MCP-3 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0683)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: E.coli; Immunogen sequence: Q24-P97

Sensitivity

<1 pg/ml

Assay Range

15.6 pg/ml - 1,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK0683 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0683 is reactive to Ccl7 in Mouse samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK0683 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of CCL7/MCP-3/MARC

Chemokine (C-C motif) ligand 7 (CCL7) is a small cytokine known as a chemokine that was previously called monocyte-specific chemokine 3 (MCP3). It belongs to the C-C chemokine family. By fluorescence in situ hybridization, mapped the MCP3 gene to chromosome 17q11.2-q12. MCP3 was identified as a physiologic substrate of gelatinase A. Cleaved MCP3 binds to CC-chemokine receptors-1, -2, and -3, but no longer induces calcium fluxes or promotes chemotaxis, and instead acts as a general chemokine antagonist that dampens inflammation, suggested that matrix metalloproteinases are both effectors and regulators of the inflammatory response.

Kit Components

Catalog Number Description Quantity
EK0683-CAP Anti-Mouse Ccl7 Pre-coated 96-well strip microplate 1
EK0683-ST Mouse Ccl7 Standard 2 vials, 10 ng/tube
EK0683-DA Mouse Ccl7 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015.631.262.51252505001000
O.D.0.0290.1440.2760.5180.8761.4091.7942.059

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect CCL7/MCP-3/MARC, Dilution ratio of 1:1, concentration in serum and plasma is 200-500 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse CCL7/MCP-3 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)3319445931176492
Standard deviation1.5113.1930.751.5814.0842.31
CV (%)4.6%6.8%6.7%8.6%8%8.6%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of CCL7/MCP-3/MARC in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 133343232320.822.5%
Sample 21942182052162089.64.6%
Sample 345944141248444926.255.8%
*number of samples for each test n=16.

Gene/Protein Information For Ccl7 (Source: Uniprot.Org, NCBI)

Gene Name

Ccl7

Full Name

C-C motif chemokine 7

Weight

10999 MW

Superfamily

intercrine beta (chemokine CC) family

Alternative Names

C-C motif chemokine 7;Intercrine/chemokine MARC;Monocyte chemoattractant protein 3;Monocyte chemotactic protein 3;MCP-3;Protein FIC;Small-inducible cytokine A7;Ccl7;Fic, Mcp3, Scya7; CCL7 FIC, MARC, MCP-3, MCP3, NC28, SCYA6, SCYA7 C-C motif chemokine ligand 7 C-C motif chemokine 7|chemokine (C-C motif) ligand 7|monocyte chemoattractant protein 3|monocyte chemotactic protein 3|small inducible cytokine A7 (monocyte chemotactic protein 3)|small-inducible cytokine A7

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on Ccl7, check out the Ccl7 Infographic

Ccl7 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for Ccl7: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK0683

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Mouse CCL7/MCP-3 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Mouse CCL7/MCP-3 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

6 Customer Q&As for Mouse CCL7/MCP-3 ELISA Kit PicoKine®

Question

Q: which procedure should I follow in order to thaw whole blood sample for CCL7 ELISA after freezing?

Verified Customer

Verified customer

Asked: 2020-02-15

Answer

A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test CCL7 for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.

Boster Scientific Support

Answered: 2020-02-15

Question

Q: What is the optimal O.D. value for CCL7 ELISA kit? I used your CCL7 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain CCL7 even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2019-02-21

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. what you should focus on is whether your sample O.D. values are statistically significantly higher than your blank values. in the above example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this CCL7 ELISA kit to have sensitivity of 1pg/ml, that means the minimum amount of CCL7 that can be declared/interpreted as positive by the above standard is 1pg/ml.

Boster Scientific Support

Answered: 2019-02-21

Question

Q: if the enzyme conjugated CCL7 antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the CCL7 antigen?

Verified Customer

Verified customer

Asked: 2018-02-15

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2018-02-15

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2017-08-02

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is a must for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2017-08-02

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

D. Li

Verified customer

Asked: 2016-12-26

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2016-12-26

Question

Q: can you recommend the dilution ratio of serum samples for detection of CCL7 in Mouse cell lysates? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have low serum volumes so we like to dilute as much as possible.

L. Sunder

Verified customer

Asked: 2014-11-24

Answer

A: unable to know the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CCL7 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2014-11-24

$499
In stock, 3+ left.

Order within 0 hours and 25 minutes to receive by Wed Nov 20

Get A Quote
In stock
Order Product
EK0683
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.