Human LILRB2 ELISA Kit PicoKine®

ILT4/CD85d/LILRB2 ELISA kit for Human

Human LILRB2 ELISA Kit PicoKine® (96 Tests). Quantitate Human LILRB2 in cell culture supernatants, serum and plasma (heparin, EDTA, citrate). Sensitivity: 50pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Product Info Summary

SKU: EK2124
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin, EDTA, citrate).

Product Name

Human LILRB2 ELISA Kit PicoKine®

View all ILT4/CD85d/LILRB2 ELISA kits

SKU/Catalog Number

EK2124

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human LILRB2 ELISA Kit PicoKine® (96 Tests). Quantitate Human LILRB2 in cell culture supernatants, serum and plasma (heparin, EDTA, citrate). Sensitivity: 50pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human LILRB2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK2124)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: NS0; Immunogen sequence: Q22-V461

Sensitivity

<50 pg/ml

Assay Range

312 pg/ml - 20,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK2124 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK2124 is reactive to LILRB2 in Human samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin, EDTA, citrate).

Application Guarantee

EK2124 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of ILT4/CD85d/LILRB2

Leukocyte immunoglobulin-like receptor subfamily B member 2 (LILRB2) is also known as CD85 antigen-like family member D (CD85d), Immunoglobulin-like transcript 4 (ILT-4), Monocyte / macrophage immunoglobulin-like receptor 10 (MIR-10), which is a member of the the subfamily B class of LIR receptors. LILRB2 is receptor for class I MHC antigens. LILRB2 recognizes a broad spectrum of HLA-A, HLA-B, HLA-C and HLA-G alleles. LILRB2 competes with CD8A for binding to class I MHC antigens. LILRB2 / CD85d inhibits FCGR1A-mediated phosphorylation of cellular proteins and mobilization of intracellular calcium ions.

Kit Components

Catalog Number Description Quantity
EK2124-CAP Anti-Human LILRB2 Pre-coated 96-well strip microplate 1
EK2124-ST Human LILRB2 Standard 2 vials, 20 ng/tube
EK2124-DA Human LILRB2 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)03126251250250050001000020000
O.D.0.0550.1250.1690.2990.5450.9561.4372.064

Data Example Images

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human LILRB2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)3842313844549224369458
Standard deviation17.28131.84388.4725.09143.72699.89
CV (%)4.5%5.7%4.6%5.1%5.9%7.4%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of ILT4/CD85d/LILRB2 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 13844013753923889.612.4%
Sample 223131997215619822112134.596.3%
Sample 384457435782672347735461.895.9%
*number of samples for each test n=16.

Gene/Protein Information For LILRB2 (Source: Uniprot.Org, NCBI)

Gene Name

LILRB2

Full Name

Leukocyte immunoglobulin-like receptor subfamily B member 2

Weight

65.039kDa

Alternative Names

Leukocyte immunoglobulin-like receptor subfamily B member 2; LIR-2; Leukocyte immunoglobulin-like receptor 2; CD85 antigen-like family member D; Immunoglobulin-like transcript 4; ILT-4; Monocyte/macrophage immunoglobulin-like receptor 10; MIR-10; CD85d; LILRB2; ILT4; LIR2; MIR10 LILRB2 CD85D, ILT-4, ILT4, LIR-2, LIR2, MIR-10, MIR10 leukocyte immunoglobulin like receptor B2 leukocyte immunoglobulin-like receptor subfamily B member 2|CD85 -like family member D|Ig-like transcript 4|leucocyte Ig-like receptor B2|leukocyte immunoglobulin-like receptor, subfamily B (with TM and ITIM domains), member 2|monocyte/macrophage immunoglobulin-like receptor 10|myeloid inhibitory receptor 10

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on LILRB2, check out the LILRB2 Infographic

LILRB2 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for LILRB2: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Loading publications

No publications found

Do you have publications using this product? Share with us and receive a reward. Contact us for more information.

Publications not available. Please try again later.

Product has been cited in publications

No results found matching your query

  • Published: --- Journal: --- Application: --- Impact Factor: --- Species: --- PMID: None

Have you used Human LILRB2 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Human LILRB2 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

8 Customer Q&As for Human LILRB2 ELISA Kit PicoKine®

Question

Q: can you suggest the dilution ratio of serum samples for detection of CD85d in Human serum? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have limited sample volumes so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2020-11-29

Answer

A: having little idea about the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CD85d ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2020-11-29

Question

Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for measuring CD85d using the EK2124 Human CD85d Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2020-08-27

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may affect the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples in order to limit protein degradation.

Boster Scientific Support

Answered: 2020-08-27

Question

Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2020-04-16

Answer

A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer can have an affect on immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2020-04-16

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

G. Patel

Verified customer

Asked: 2020-04-06

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2020-04-06

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2018-10-05

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2018-10-05

Question

Q: Can CD85d ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

T. Chen

Verified customer

Asked: 2018-04-07

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2018-04-07

Question

Q: how much samples can be assayed in a Picokine® ELISA Kit?

J. Gonzalez

Verified customer

Asked: 2016-06-14

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2016-06-14

Question

Q: if the enzyme conjugated CD85d antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the CD85d antigen?

W. Li

Verified customer

Asked: 2014-05-03

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2014-05-03

$750
Backordered.

Lead time for this item is typically 2-3 weeks

Get A Quote
In stock
Order Product
EK2124
$750.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.