Human CSF3R/G-CSF R ELISA Kit PicoKine®

G-CSFR/CD114 ELISA kit for Human

Human CSF3R/G-CSF R ELISA Kit PicoKine® (96 Tests). Quantitate Human CSF3R in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Product Info Summary

SKU: EK0766
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Human CSF3R/G-CSF R ELISA Kit PicoKine®

View all G-CSFR/CD114 ELISA kits

SKU/Catalog Number

EK0766

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human CSF3R/G-CSF R ELISA Kit PicoKine® (96 Tests). Quantitate Human CSF3R in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human CSF3R/G-CSF R ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0766)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: NS0; Immunogen sequence: E25-P621

Sensitivity

<10 pg/ml

Assay Range

31.2 pg/ml - 2,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK0766 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0766 is reactive to CSF3R in Human samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK0766 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of G-CSFR/CD114

The granulocyte colony-stimulating factor receptor (G-CSF-R), also known as CD114 (Cluster of Differentiation 114), is a protein that in humans is encoded by the CSF3R gene. It is mapped to 1p35-p34.3. G-CSF-R is a cell-surface receptor for the granulocyte colony-stimulating factor (G-CSF). And the G-CSF-R is a transmembrane receptor that consists of an extracellular ligand-binding portion, a transmembrane domain, and the cytoplasmic portion that is responsible for signal transduction. In addition, GCSF-R ligand-binding is associated with dimerization of the receptor and signal transduction through proteins including Jak, Lyn, STAT, andErk1/2.

Kit Components

Catalog Number Description Quantity
EK0766-CAP Anti-Human CSF3R Pre-coated 96-well strip microplate 1
EK0766-ST Human CSF3R Standard 2 vials, 10 ng/tube
EK0766-DA Human CSF3R Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)031.262.512525050010002000
O.D.0.0410.1330.1770.3560.5701.0231.4982.002

Data Example Images

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human CSF3R/G-CSF R ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)7222282369240838
Standard deviation5.549.9959.256.2718.1267.87
CV (%)7.7%4.5%7.2%9.1%6.3%8.1%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of G-CSFR/CD114 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 172778486795.587%
Sample 222222425524523613.975.9%
Sample 382387987273482757.866.9%
*number of samples for each test n=16.

Gene/Protein Information For CSF3R (Source: Uniprot.Org, NCBI)

Gene Name

CSF3R

Full Name

Granulocyte colony-stimulating factor receptor

Weight

92156 MW

Superfamily

type I cytokine receptor family

Alternative Names

Granulocyte colony-stimulating factor receptor;G-CSF receptor;G-CSF-R;CD114;CSF3R;GCSFR; CSF3R CD114, GCSFR, SCN7 colony stimulating factor 3 receptor granulocyte colony-stimulating factor receptor|CD114 |G-CSF receptor|G-CSF-R|colony stimulating factor 3 receptor (granulocyte)

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on CSF3R, check out the CSF3R Infographic

CSF3R infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for CSF3R: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK0766

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Human CSF3R/G-CSF R ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Human CSF3R/G-CSF R ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

8 Customer Q&As for Human CSF3R/G-CSF R ELISA Kit PicoKine®

Question

Q: how do I analyze ELISA data? I have obtained CD114 level in cell lysates.

Verified Customer

Verified customer

Asked: 2020-12-18

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2020-12-18

Question

Q: can you tell me how to prepare cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2020-11-25

Answer

A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are included in the product insert. Components in lysate and lysis buffer can impact immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2020-11-25

Question

Q: how can I thaw whole blood sample for CD114 ELISA after freezing?

Verified Customer

Verified customer

Asked: 2020-10-24

Answer

A: we do not recommend freezing and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test CD114 for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.

Boster Scientific Support

Answered: 2020-10-24

Question

Q: we need your suggestion regarding the dilution ratio of serum samples for detection of CD114 in Human cell lysates? I am trying to measure a multiple analytes and it requires 100ul of diluted samples for each well. We have low serum quantitys so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2019-09-26

Answer

A: without having an understanding the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CD114 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2019-09-26

Question

Q: is it okay to use citrate plasma as samples in Human CD114 Picokine® ELISA Kit (Catalog # EK0766)?

Z. Kulkarni

Verified customer

Asked: 2019-04-13

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can attach metal ions from the functional domain of CD114 causing disruption of its protein structure. CD114 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the CD114 ELISA, treating samples with different anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2019-04-13

Question

Q: Can CD114 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2019-02-25

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please view the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2019-02-25

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2016-05-28

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2016-05-28

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

W. Wu

Verified customer

Asked: 2016-03-23

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2016-03-23

$499
In stock, 2 left.

Order within 82 hours and 36 minutes to receive by Tue Nov 26

Get A Quote
In stock
Order Product
EK0766
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.