Product Info Summary
SKU: | EK1578 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Mouse |
Application: | ELISA |
Sample Types: | cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). |
Product info
Product Name
Mouse DKK4 ELISA Kit PicoKine®
SKU/Catalog Number
EK1578
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Mouse DKK4 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Dkk4 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Mouse DKK4 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1578)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: L19-I221
Sensitivity
<10 pg/ml
Assay Range
78 pg/ml - 5,000 pg/ml
Standard Dilution Instructions
See datasheet of EK1578 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK1578 is reactive to Dkk4 in Mouse samples
Validated Sample Types
cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).
Application Guarantee
EK1578 is guaranteed for ELISA in Mouse by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of Dkk-4
DKK4 is a membersof the Dickkopf family which are negative regulators of the growth-promoting Wnt / beta-catenin signaling pathway. By FISH, the DKK4 gene was mapped to chromosome 8p11.2-p11.1. The secreted protein contains two cysteine rich regions and is involved in embryonic development through its interactions with the Wnt signaling pathway. Activity of this protein is modulated by binding to the Wnt co-receptor and the co-factor kremen 2. The expression of DKK4 was significantly reduced in hepatocellular carcinomas (HCCs), particularly in HCCs that showed cytoplasmic beta- catenin accumulation. DKK4 expression was also reduced in HCC cell lines. Ectopic expression of DKK4 in 2 HCC cell lines reduced beta-catenin and cyclin D1 protein levels and attenuated beta-catenin activity in reporter gene assays.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK1578-CAP | Anti-Mouse Dkk4 Pre-coated 96-well strip microplate | 1 |
EK1578-ST | Mouse Dkk4 Standard | 2 vials, 10 ng/tube |
EK1578-DA | Mouse Dkk4 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 78 | 156 | 312 | 625 | 1250 | 2500 | 5000 |
O.D. | 0.011 | 0.042 | 0.073 | 0.129 | 0.247 | 0.534 | 1.147 | 2.004 |
Data Example Images
Click image to see more details
Mouse DKK4 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect Dkk-4, Dilution ratio of 1:1, concentration in serum and plasma is less than the lowest standard, 78 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Mouse DKK4 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 115 | 828 | 2616 | 104 | 829 | 2555 |
Standard deviation | 7.13 | 36.43 | 133.41 | 7.9%1 | 51.39 | 178.85 |
CV (%) | 6.2% | 4.4% | 7%% | 7.9% | 6.2% | 7% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of Dkk-4 in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 115 | 112 | 113 | 121 | 115 | 3.49 | 3% |
Sample 2 | 828 | 710 | 788 | 755 | 770 | 43.33 | 5.6% |
Sample 3 | 2616 | 2592 | 2575 | 2681 | 2616 | 40.25 | 1.5% |
Protein Target Info & Infographic
Gene/Protein Information For Dkk4 (Source: Uniprot.Org, NCBI)
Gene Name
Dkk4
Full Name
Dickkopf-related protein 4
Weight
24261 MW
Superfamily
dickkopf family
Alternative Names
Dickkopf-related protein 4;Dickkopf-4;Dkk-4;Dkk4; DKK4 DKK-4 dickkopf WNT signaling pathway inhibitor 4 dickkopf-related protein 4|dickkopf-4|hDkk-4
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on Dkk4, check out the Dkk4 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for Dkk4: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Mouse DKK4 ELISA Kit PicoKine® (EK1578)
Hello CJ!
No publications found for EK1578
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Mouse DKK4 ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Mouse DKK4 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
7 Customer Q&As for Mouse DKK4 ELISA Kit PicoKine®
Question
Q: we need your recommendation regarding the dilution ratio of serum samples for detection of Dkk-4 in Mouse serum? I am trying to measure a multiple analytes and it requires 100ul of diluted samples for each well. We have low serum quantitys so we like to dilute as much as possible.
Verified Customer
Verified customer
Asked: 2019-10-28
Answer
A: unable to know the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the Dkk-4 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2019-10-28
Question
Q: can I use citrate plasma as samples in Mouse Dkk-4 Picokine® ELISA Kit (Catalog # EK1578)?
Verified Customer
Verified customer
Asked: 2019-09-07
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can sequester metal ions from the functional domain of Dkk-4 causing degradation of its protein structure. Dkk-4 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the Dkk-4 ELISA, treating samples with different anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2019-09-07
Question
Q: how many samples can be assayed in a Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2019-08-06
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2019-08-06
Question
Q: Can Dkk-4 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
Verified Customer
Verified customer
Asked: 2019-02-21
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is needed. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2019-02-21
Question
Q: if the enzyme conjugated Dkk-4 antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the Dkk-4 antigen?
Verified Customer
Verified customer
Asked: 2018-03-19
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2018-03-19
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
G. Clark
Verified customer
Asked: 2018-02-10
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is needed for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2018-02-10
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
Verified Customer
Verified customer
Asked: 2017-06-14
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions
Boster Scientific Support
Answered: 2017-06-14