Product Info Summary
SKU: | EK0701 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Mouse |
Application: | ELISA |
Sample Types: | cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). |
Product info
Product Name
Mouse CD36/SR-B3/GP4 ELISA Kit PicoKine®
View all CD36/SR-B3 ELISA kits
SKU/Catalog Number
EK0701
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Mouse CD36/SR-B3 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Cd36 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Mouse CD36/SR-B3/GP4 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0701)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: CHO; Immunogen sequence: G30-K439
Sensitivity
<10 pg/ml
Assay Range
156 pg/ml - 10,000 pg/ml
Standard Dilution Instructions
See datasheet of EK0701 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0701 is reactive to Cd36 in Mouse samples
Validated Sample Types
cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).
Application Guarantee
EK0701 is guaranteed for ELISA in Mouse by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of CD36/SR-B3
CD36 (Cluster of Differentiation 36) is an integral membrane protein found on the surface of many cell types in vertebrate animals and is also known as FAT, SCARB3, GP88, glycoprotein IV (gpIV) and glycoprotein IIIb (gpIIIb). The human CD36 is a member of a gene family of structurally related glycoproteins and functions as a receptor for collagen type I and thrombospondin. The use of a CD36 genomic probe has allowed the localization of the CD36 locus to the 7q11.2 band by fluorescence in situ hybridization coupled with GTG-banding. CED-1/SCARF1 and C03F11.3/CD36 are beta-glucan binding receptors and define an evolutionarily conserved pathway for the innate sensing of fungal pathogens.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK0701-CAP | Anti-Mouse Cd36 Pre-coated 96-well strip microplate | 1 |
EK0701-ST | Mouse Cd36 Standard | 2 vials, 10 ng/tube |
EK0701-DA | Mouse Cd36 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 156 | 312 | 625 | 125000 | 25000 | 5000 | 10000 |
O.D. | 0.042 | 0.144 | 0.215 | 0.343 | 0.598 | 1.024 | 1.771 | 2.326 |
Data Example Images
Click image to see more details
Mouse CD36/SR-B3 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect CD36/SR-B3, Dilution ratio of 1:1, concentration in serum and plasma is less than the lowest standard, 156 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Mouse CD36/SR-B3/GP4 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 327 | 1000 | 4032 | 308 | 1073 | 3654 |
Standard deviation | 13.73 | 67 | 221.76 | 18.78 | 83.69 | 204.62 |
CV (%) | 4.2% | 6.7% | 5.5% | 6.1% | 7.8% | 5.6% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of CD36/SR-B3 in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 327 | 332 | 292 | 319 | 317 | 15.43 | 4.8% |
Sample 2 | 1000 | 1134 | 1146 | 1166 | 1111 | 65.38 | 5.8% |
Sample 3 | 4032 | 3785 | 4495 | 4279 | 4147 | 265.89 | 6.4% |
Protein Target Info & Infographic
Gene/Protein Information For Cd36 (Source: Uniprot.Org, NCBI)
Gene Name
Cd36
Full Name
Platelet glycoprotein 4
Weight
52698 MW
Superfamily
CD36 family
Alternative Names
Platelet glycoprotein 4;Glycoprotein IIIb;GPIIIB;PAS IV;PAS-4;Platelet glycoprotein IV;GPIV;CD36;Cd36; CD36 BDPLT10, CHDS7, FAT, GP3B, GP4, GPIV, PASIV, SCARB3 CD36 molecule platelet glycoprotein 4|CD36 (collagen type I receptor, thrombospondin receptor)|CD36 molecule (thrombospondin receptor)|GPIIIB|PAS IV|PAS-4 protein|cluster determinant 36|fatty acid translocase|glycoprotein IIIb|leukocyte differentiation CD36|platelet glycoprotein IV|scavenger receptor class B, member 3
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on Cd36, check out the Cd36 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for Cd36: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Mouse CD36/SR-B3/GP4 ELISA Kit PicoKine® (EK0701)
Hello CJ!
No publications found for EK0701
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Mouse CD36/SR-B3/GP4 ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Mouse CD36/SR-B3/GP4 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
5 Customer Q&As for Mouse CD36/SR-B3/GP4 ELISA Kit PicoKine®
Question
Q: how many samples can be assayed in a Picokine® ELISA Kit?
A. Chen
Verified customer
Asked: 2019-12-29
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2019-12-29
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
Verified Customer
Verified customer
Asked: 2019-08-19
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions
Boster Scientific Support
Answered: 2019-08-19
Question
Can EK0701 detect soluble CD36?
Verified Customer
Verified customer
Asked: 2019-06-04
Answer
EK0701 can detect soluble CD36.
Boster Scientific Support
Answered: 2019-06-04
Question
Q: Can CD36 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
Verified Customer
Verified customer
Asked: 2017-04-11
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2017-04-11
Question
Q: if the enzyme conjugated CD36 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the CD36 antigen?
Verified Customer
Verified customer
Asked: 2016-05-27
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2016-05-27