Product Info Summary
SKU: | EK0959 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Human |
Application: | ELISA |
Sample Types: | cell culture supernatants, serum and plasma (heparin). |
Product info
Product Name
Human PD-1 ELISA Kit PicoKine®
SKU/Catalog Number
EK0959
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human PD-1 ELISA Kit PicoKine® (96 Tests). Quantitate Human PDCD1 in cell culture supernatants, serum and plasma (heparin). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human PD-1 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0959)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: L25-Q167
Sensitivity
<10 pg/ml
Assay Range
31.2 pg/ml - 2,000 pg/ml
Standard Dilution Instructions
See datasheet of EK0959 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0959 is reactive to PDCD1 in Human samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin).
Application Guarantee
EK0959 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of PD-1
Programmed cell death protein 1, also called PD-1 or PDCD1 is a protein that in humans is encoded by the PDCD1 gene. This gene encodes a cell surface membrane protein of the immunoglobulin superfamily. By fluorescence in situ hybridization, the PDCD1 gene is mapped to 2q37.3. This protein is expressed in pro-B-cells and is thought to play a role in their differentiation. In mice, expression of this gene is induced in the thymus when anti-CD3 antibodies are injected and large numbers of thymocytes undergo apoptosis. Mice deficient for this gene bred on a BALB/c background developed dilated cardiomyopathy and died from congestive heart failure. These studies suggest that this gene product may also be important in T cell function and contribute to the prevention of autoimmune diseases.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK0959-CAP | Anti-Human PDCD1 Pre-coated 96-well strip microplate | 1 |
EK0959-ST | Human PDCD1 Standard | 2 vials, 10 ng/tube |
EK0959-DA | Human PDCD1 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 | 2000 |
O.D. | 0.002 | 0.054 | 0.102 | 0.189 | 0.360 | 0.660 | 1.042 | 1.907 |
Data Example Images
Click image to see more details
Human PD-1 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect PD-1, Dilution ratio of 1:1, concentration in serum and plasma is 80-120 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human PD-1 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 17 | 88 | 267 | 22 | 96 | 314 |
Standard deviation | 0.71 | 4.49 | 13.88 | 1.12 | 4.99 | 19.78 |
CV (%) | 4.2% | 5.1% | 5.2% | 5.1% | 5.2% | 6.3% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of PD-1 in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 17 | 25 | 30 | 19 | 23 | 0.41 | 1.8% |
Sample 2 | 88 | 94 | 101 | 79 | 91 | 2.35 | 2.6% |
Sample 3 | 267 | 294 | 315 | 302 | 295 | 18.26 | 6.2% |
Protein Target Info & Infographic
Gene/Protein Information For PDCD1 (Source: Uniprot.Org, NCBI)
Gene Name
PDCD1
Full Name
Programmed cell death protein 1
Weight
31647 MW
Alternative Names
Programmed cell death protein 1;Protein PD-1;hPD-1;CD279;PDCD1;PD1; PDCD1 CD279, PD-1, PD1, SLEB2, hPD-1, hPD-l, hSLE1 programmed cell death 1 programmed cell death protein 1|programmed cell death 1 protein|protein PD-1|systemic lupus erythematosus susceptibility 2
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on PDCD1, check out the PDCD1 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for PDCD1: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Human PD-1 ELISA Kit PicoKine® (EK0959)
Hello CJ!
No publications found for EK0959
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Human PD-1 ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Human PD-1 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
7 Customer Q&As for Human PD-1 ELISA Kit PicoKine®
Question
Q: What is the optimal O.D. value for PD-1 ELISA kit? I performed your PD-1 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain PD-1 even though the O.D. values are not very high?
K. Garcia
Verified customer
Asked: 2020-09-07
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. what you should focus on is whether your sample O.D. values are statistically significantly higher than your blank values. regarding your assay, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this PD-1 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of PD-1 that can be declared/interpreted as positive by the above standard is 10pg/ml.
Boster Scientific Support
Answered: 2020-09-07
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
Verified Customer
Verified customer
Asked: 2019-08-11
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2019-08-11
Question
Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for measurement PD-1 using the EK0959 Human PD-1 Picokine® ELISA Kit?
G. Singh
Verified customer
Asked: 2019-06-30
Answer
A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample immediately after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples in order to prevent protein degradation.
Boster Scientific Support
Answered: 2019-06-30
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
Verified Customer
Verified customer
Asked: 2019-06-21
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions
Boster Scientific Support
Answered: 2019-06-21
Question
Q: how to analyze ELISA data? I have performed PD-1 level in serum.
M. Huang
Verified customer
Asked: 2018-05-01
Answer
A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online
Boster Scientific Support
Answered: 2018-05-01
Question
Q: how can I thaw whole blood sample for PD-1 ELISA after freezing?
Z. Anand
Verified customer
Asked: 2014-07-09
Answer
A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test PD-1 for a later time, you should let the blood clot in glass tubes and collect the serum to freeze for later use.
Boster Scientific Support
Answered: 2014-07-09
Question
Q: can I use citrate plasma as samples in Human PD-1 Picokine® ELISA Kit (Catalog # EK0959)?
M. Walker
Verified customer
Asked: 2014-02-06
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can bind metal ions from the functional domain of PD-1 causing degradation of its protein structure. PD-1 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes needed for detection and block the antigen antibody reaction. We have tested the PD-1 ELISA, treating samples with different anticoagulants and decided that heparin can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2014-02-06