Human Neutrophil Elastase/ELA2/ELANE ELISA Kit PicoKine®

Neutrophil Elastase/ELA2 ELISA kit for Human

Human Neutrophil Elastase/ELA2/ELANE ELISA Kit PicoKine® (96 Tests). Quantitate Human ELANE in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 50pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays. Cited in 4 publication(s).

Product Info Summary

SKU: EK2064
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin, EDTA).

Product Name

Human Neutrophil Elastase/ELA2/ELANE ELISA Kit PicoKine®

View all Neutrophil Elastase/ELA2 ELISA kits

SKU/Catalog Number

EK2064

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human Neutrophil Elastase/ELA2/ELANE ELISA Kit PicoKine® (96 Tests). Quantitate Human ELANE in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 50pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human Neutrophil Elastase/ELA2/ELANE ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK2064)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: NS0; Immunogen sequence: I30-H267

Sensitivity

<50 pg/ml

Assay Range

0.78 ng/ml - 50 ng/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK2064 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK2064 is reactive to ELANE in Human samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin, EDTA).

Application Guarantee

EK2064 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of Neutrophil Elastase/ELA2

In humans, neutrophil elastase is encoded by the ELANE gene, which resides on chromosome 19. It is mapped to 19p13.3. Elastases form a subfamily of serine proteases that hydrolyze many proteins in addition to elastin. Humans have six elastase genes which encode structurally similar proteins. The encoded preproprotein is proteolytically processed to generate the active protease. Following activation, this protease hydrolyzes proteins within specialized neutrophil lysosomes, called azurophil granules, as well as proteins of the extracellular matrix. The enzyme may play a role in degenerative and inflammatory diseases through proteolysis of collagen-IV and elastin. This protein also degrades the outer membrane protein A (OmpA) of E. coli as well as the virulence factors of such bacteria as Shigella, Salmonella and Yersinia. Mutations in this gene are associated with cyclic neutropenia and severe congenital neutropenia (SCN). This gene is present in a gene cluster on chromosome 19.

Kit Components

Catalog Number Description Quantity
EK2064-CAP Anti-Human ELANE Pre-coated 96-well strip microplate 1
EK2064-ST Human ELANE Standard 2 vials, 50 ng/tube
EK2064-DA Human ELANE Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (ng/ml)00.781.563.126.2512.52550
O.D.0.0950.1030.1220.1450.2430.5341.2742.098

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect Neutrophil Elastase/ELA2, Dilution ratio of 1:300, concentration in serum and plasma is around 400 ng/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human Neutrophil Elastase/ELA2/ELANE ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)11745107219471365616523984
Standard deviation48.13214.49987.6264.16332.911367.09
CV (%)4.1%4.2%4.5%4.7%5.4%5.7%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of Neutrophil Elastase/ELA2 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 11174107111081106111437.233.3%
Sample 251075193451547914901268.695.4%
Sample 32194721460196632011520796937.164.5%
*number of samples for each test n=16.

Gene/Protein Information For ELANE (Source: Uniprot.Org, NCBI)

Gene Name

ELANE

Full Name

Neutrophil elastase

Weight

28.518kDa

Superfamily

peptidase S1 family

Alternative Names

Neutrophil elastase; Bone marrow serine protease; Elastase-2; Human leukocyte elastase; HLE; Medullasin; PMN elastase; ELANE; ELA2 ELANE ELA2, GE, HLE, HNE, NE, PMN-E, SCN1 elastase, neutrophil expressed neutrophil elastase|PMN elastase|bone marrow serine protease|elastase 2, neutrophil|elastase-2|granulocyte-derived elastase|leukocyte elastase|medullasin|polymorphonuclear elastase

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on ELANE, check out the ELANE Infographic

ELANE infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for ELANE: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK2064 has been cited in 4 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

The Burkholderia cenocepacia OmpA-like protein BCAL2958: identification, characterization, and detection of anti-BCAL2958 antibodies in serum from B. cepacia complex-infected Cystic Fibrosis patients

Expressions of MMP-12, TIMP-4, and Neutrophil Elastase in PBMCs and Exhaled Breath Condensate in Patients with COPD and Their Relationships with Disease Severity and Acute Exacerbations

Mechanism of neutrophil extracellular traps generation and their role in trophoblasts apoptosis in gestational diabetes mellitus

The Burkholderia cenocepacia OmpA-like protein BCAL2958: identification, characterization, and detection of anti-BCAL2958 antibodies in serum from B cepacia complex-infected Cystic Fibrosis patients

Have you used Human Neutrophil Elastase/ELA2/ELANE ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Human Neutrophil Elastase/ELA2/ELANE ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

7 Customer Q&As for Human Neutrophil Elastase/ELA2/ELANE ELISA Kit PicoKine®

Question

Q: What is the optimal O.D. value for Neutrophil Elastase ELISA kit? I used your Neutrophil Elastase ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain Neutrophil Elastase even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2020-11-27

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in the example mentioned, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this Neutrophil Elastase ELISA kit to have sensitivity of 50pg/ml, that means the minimum amount of Neutrophil Elastase that can be declared/interpreted as positive by the above standard is 50pg/ml.

Boster Scientific Support

Answered: 2020-11-27

Question

Q: Can Neutrophil Elastase ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2020-05-02

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2020-05-02

Question

Q: how much samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2020-04-06

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2020-04-06

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2020-02-09

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is a must for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2020-02-09

Question

Q: if the enzyme conjugated Neutrophil Elastase antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the Neutrophil Elastase antigen?

Verified Customer

Verified customer

Asked: 2019-10-14

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2019-10-14

Question

Q: how do I analyze ELISA data? I measured Neutrophil Elastase level in serum.

C. Martin

Verified customer

Asked: 2019-05-13

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. we also provide a convenient online tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2019-05-13

Question

Q: can you suggest the dilution ratio of serum samples for detection of Neutrophil Elastase in Human serum? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have low serum volumes so we like to dilute as much as possible.

G. Jha

Verified customer

Asked: 2016-10-01

Answer

A: without knowing the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the Neutrophil Elastase ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2016-10-01

$499
In stock, 3+ left.

Order within 0 hours and 46 minutes to receive by Fri Nov 22

Get A Quote
In stock
Order Product
EK2064
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.