Product Info Summary
SKU: | FC01690-iFluor647 |
---|---|
Size: | 100 tests, 200 tests |
Reactive Species: | Human |
Host: | Mouse |
Application: | Flow Cytometry |
Customers Who Bought This Also Bought
Product info
Product Name
Anti-Human CD32 FCGR2A Monoclonal Antibody iFluor647 Conjugated, Flow Validated
SKU/Catalog Number
FC01690-iFluor647
Size
100 tests, 200 tests
Form
Liquid, in PBS, pH7.2, <0.09% NaN3 and 0.2% (w/v) BSA
Description
Boster Bio Anti-Human CD32 FCGR2A Monoclonal Antibody iFluor647 Conjugated, Flow Validated (Catalog# FC01690-iFluor647). Tested in Flow Cytometry application(s). This antibody reacts with Human.
Storage & Handling
Store at 2-8°C. Avoid repeated freeze-thaw cycles.
Cite This Product
Anti-Human CD32 FCGR2A Monoclonal Antibody iFluor647 Conjugated, Flow Validated (Boster Biological Technology, Pleasanton CA, USA, Catalog # FC01690-iFluor647)
Host
Mouse
Contents
PBS pH 7.2, 0.2% (w/v) BSA, 0.09% (w/v) sodium azide
Clonality
Monoclonal
Clone Number
Clone: IV.3
Isotype
IgG2b,k
Immunogen
K-562 human erythromyeloblastoid leukemia cell line
*Blocking peptide can be purchased. Costs vary based on immunogen length. Contact us for pricing.
Reactive Species
FC01690-iFluor647 is reactive to FCGR2A in Human
Reconstitution
Observed Molecular Weight
68 kDa
Calculated molecular weight
35,001 MW
Antibody Validation
Boster validates all antibodies on WB, IHC, ICC, Immunofluorescence, and ELISA with known positive control and negative samples to ensure specificity and high affinity, including thorough antibody incubations.
Application & Images
Applications
FC01690-iFluor647 is guaranteed for Flow Cytometry Boster Guarantee
Assay Dilutions Recommendation
The recommendations below provide a starting point for assay optimization. The actual working concentration varies and should be decided by the user.
User needs to optimize the dilution ratio for this antibody.
Validation Images & Assay Conditions
Click image to see more details
Monocytes gated PBMCs stained with iFluor647 conjugated anti-human CD32 (clone IV.3) (red histogram). Monocytes gated PBMCs FMO is used as control (blue histogram).
Protein Target Info & Infographic
Gene/Protein Information For FCGR2A (Source: Uniprot.org, NCBI)
Gene Name
FCGR2A
Full Name
Low affinity immunoglobulin gamma Fc region receptor II-a
Weight
35,001 MW
Alternative Names
Low affinity immunoglobulin gamma Fc region receptor II-a; IgG Fc receptor II-a, CDw32, Fc-gamma RII-a;Fc-gamma-RIIa ; FcRII-a,CD32, FCG2, FCGR2A1, IGFR2 FCGR2A CD32, CD32A, CDw32, FCG2, FCGR21, FcGR, IGFR2, FCGR2A Fc fragment of IgG receptor IIa low affinity immunoglobulin gamma Fc region receptor II-a|Fc fragment of IgG, low affinity IIa, receptor (CD32)|Fc gamma receptor RIIa3|Immunoglobulin G Fc receptor II|fc-gamma-RIIa|fcRII-a|igG Fc receptor II-a
*If product is indicated to react with multiple species, protein info is based on the gene entry specified above in "Species".For more info on FCGR2A, check out the FCGR2A Infographic
We have 30,000+ of these available, one for each gene! Check them out.
In this infographic, you will see the following information for FCGR2A: database IDs, superfamily, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post-translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact [email protected].
Specific Publications For Anti-Human CD32 FCGR2A Monoclonal Antibody iFluor647 Conjugated, Flow Validated (FC01690-iFluor647)
Hello CJ!
No publications found for FC01690-iFluor647
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Anti-Human CD32 FCGR2A Monoclonal Antibody iFluor647 Conjugated, Flow Validated?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Anti-Human CD32 FCGR2A Monoclonal Antibody iFluor647 Conjugated, Flow Validated
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
3 Customer Q&As for Anti-Human CD32 FCGR2A Monoclonal Antibody iFluor647 Conjugated, Flow Validated
Question
Is this FC01690-iFluor647 anti-Human CD32 Monoclonal antibody iFluor647 Conjugated, Flow Validated reactive to the isotypes of FCGR2A?
Verified Customer
Verified customer
Asked: 2018-09-18
Answer
The immunogen of FC01690-iFluor647 anti-Human CD32 Monoclonal antibody iFluor647 Conjugated, Flow Validated is K-562 human erythromyeloblastoid leukemia cell line. Could you tell me which isotype you are interested in so I can help see if the immunogen is part of this isotype?
Boster Scientific Support
Answered: 2018-09-18
Question
I was wanting to use to test anti-Human CD32 Monoclonal antibody iFluor647 Conjugated, Flow Validated FC01690-iFluor647 on human blood for research purposes, then I may be interested in using anti-Human CD32 Monoclonal antibody iFluor647 Conjugated, Flow Validated FC01690-iFluor647 for diagnostic purposes as well. Is the antibody suitable for diagnostic purposes?
Verified Customer
Verified customer
Asked: 2018-03-26
Answer
The products we sell, including anti-Human CD32 Monoclonal antibody iFluor647 Conjugated, Flow Validated FC01690-iFluor647, are only intended for research use. They would not be suitable for use in diagnostic work. If you have the means to develop a product into diagnostic use, and are interested in collaborating with us and develop our product into an IVD product, please contact us for more discussions.
Boster Scientific Support
Answered: 2018-03-26
Question
I was wanting to use your anti-Human CD32 Monoclonal antibody iFluor647 Conjugated, Flow Validated for Flow Cytometry for human blood on frozen tissues, but I want to know if it has been tested for this particular application. Has this antibody been tested and is this antibody a good choice for human blood identification?
O. Moore
Verified customer
Asked: 2015-09-28
Answer
You can see on the product datasheet, FC01690-iFluor647 anti-Human CD32 Monoclonal antibody iFluor647 Conjugated, Flow Validated has been validated for Flow Cytometry on human tissues. We have an innovator award program that if you test this antibody and show it works in human blood in IHC-frozen, you can get your next antibody for free.
Boster Scientific Support
Answered: 2015-09-28