Rat Eotaxin ELISA Kit PicoKine®

CCL11/Eotaxin ELISA kit for Rat

Rat Eotaxin ELISA Kit PicoKine® (96 Tests). Quantitate Rat Ccl11 in cell culture supernatants, serum and plasma (EDTA, citrate). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays. Cited in 1 publication(s).

Product Info Summary

SKU: EK1435
Size: 96 wells/kit, with removable strips.
Reactive Species: Rat
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (EDTA, citrate).

Product Name

Rat Eotaxin ELISA Kit PicoKine®

View all CCL11/Eotaxin ELISA kits

SKU/Catalog Number

EK1435

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Rat Eotaxin ELISA Kit PicoKine® (96 Tests). Quantitate Rat Ccl11 in cell culture supernatants, serum and plasma (EDTA, citrate). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Rat Eotaxin ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1435)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: E.coli; Immunogen sequence: H24-P97

Sensitivity

<10 pg/ml

Assay Range

31.2 pg/ml - 2,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK1435 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1435 is reactive to Ccl11 in Rat samples

Validated Sample Types

cell culture supernatants, serum and plasma (EDTA, citrate).

Application Guarantee

EK1435 is guaranteed for ELISA in Rat by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of CCL11/Eotaxin

Eotaxin, also known as CCL11, is a potent inducer of eosinophil chemotaxis and is considered as a selective ligand of the CC chemokine receptor 3 (CCR3), which is expressed on eosinophils, basophils, and Th2 lymphocytes. Eotaxin is assumed to be involved in eosinophilic inflammatory diseases such as atopic dermatitis, allergic rhinitis, asthma and parasitic infections. The gene maps to chromosome 17 and is expressed constitutively at high levels in small intestine and colon, and at lower levels in various other tissues. The deduced mature protein sequence is 66% identical to human monocyte chemoattractant protein-1, and 60% identical to guinea pig eotaxin.

Kit Components

Catalog Number Description Quantity
EK1435-CAP Anti-Rat Ccl11 Pre-coated 96-well strip microplate 1
EK1435-ST Rat Ccl11 Standard 2 vials, 10 ng/tube
EK1435-DA Rat Ccl11 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)031.262.512525050010002000
O.D.0.0750.1540.2170.3590.6341.1951.5222.006

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect CCL11/Eotaxin, Dilution ratio of 1:4, concentration in serum and plasma is around 1 ng/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Rat Eotaxin ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)532221050584641127
Standard deviation3.7112.8864.053.0719.4966.50
CV (%)7%5.8%6.1%5.3%4.2%5.9%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of CCL11/Eotaxin in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 153515153521.001.9%
Sample 222221224023622711.164.9%
Sample 3105010179571091102849.024.7%
*number of samples for each test n=16.

Gene/Protein Information For Ccl11 (Source: Uniprot.Org, NCBI)

Gene Name

Ccl11

Full Name

Eotaxin

Weight

10851 MW

Superfamily

intercrine beta (chemokine CC) family

Alternative Names

Eotaxin;C-C motif chemokine 11;Eosinophil chemotactic protein;Small-inducible cytokine A11;Ccl11;Scya11; CCL11 SCYA11 C-C motif chemokine ligand 11 eotaxin|chemokine (C-C motif) ligand 11|eosinophil chemotactic protein|eotaxin-1|small inducible cytokine subfamily A (Cys-Cys), member 11 (eotaxin)

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on Ccl11, check out the Ccl11 Infographic

Ccl11 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for Ccl11: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK1435 has been cited in 1 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

JAX2, an ethanol extract of Hyssopus cuspidatus Boriss, can prevent bronchial asthma by inhibiting MAPK/NF-κB inflammatory signaling

Have you used Rat Eotaxin ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Rat Eotaxin ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

8 Customer Q&As for Rat Eotaxin ELISA Kit PicoKine®

Question

Q: how do I analyze ELISA data? I measured CCL11 level in serum.

Verified Customer

Verified customer

Asked: 2020-12-12

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2020-12-12

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2020-05-28

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2020-05-28

Question

Q: which procedure should I follow in order to thaw whole blood sample for CCL11 ELISA after freezing?

Verified Customer

Verified customer

Asked: 2019-11-27

Answer

A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test CCL11 for a later time, you should let the blood clot in glass tubes and collect the serum to freeze for later use.

Boster Scientific Support

Answered: 2019-11-27

Question

Q: What is the optimal O.D. value for CCL11 ELISA kit? I performed your CCL11 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain CCL11 even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2019-10-18

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. a point of focus should be is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this CCL11 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of CCL11 that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2019-10-18

Question

Q: is it okay to use heparin plasma as samples in Rat CCL11 Picokine® ELISA Kit (Catalog # EK1435)?

Y. Yang

Verified customer

Asked: 2019-10-11

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can sequester metal ions from the functional domain of CCL11 causing degradation of its protein structure. CCL11 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the CCL11 ELISA, treating samples with various anticoagulants and decided that EDTA or citrate can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2019-10-11

Question

Q: we need your suggestion regarding the dilution ratio of serum samples for detection of CCL11 in Rat serum? I am trying to measure a few parameters and it requires 100ul of diluted samples for each well. We have limited sample quantitys so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2018-06-07

Answer

A: without knowing the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CCL11 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2018-06-07

Question

Q: Can CCL11 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2018-04-12

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please view the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2018-04-12

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Z. Davis

Verified customer

Asked: 2016-07-03

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2016-07-03

$499
In stock, 1 left.

Order within -3 hours and -12 minutes to receive by Fri Nov 22

Get A Quote
In stock
Order Product
EK1435
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.