Mouse Eotaxin-1 ELISA Kit PicoKine®

CCL11/Eotaxin ELISA kit for Mouse

Mouse Eotaxin-1 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Ccl11 in cell culture supernatants, serum and plasma (citrate, EDTA). Sensitivity: 1pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays. Cited in 4 publication(s).

Product Info Summary

SKU: EK0330
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (citrate, EDTA).

Product Name

Mouse Eotaxin-1 ELISA Kit PicoKine®

View all CCL11/Eotaxin ELISA kits

SKU/Catalog Number

EK0330

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse Eotaxin-1 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Ccl11 in cell culture supernatants, serum and plasma (citrate, EDTA). Sensitivity: 1pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse Eotaxin-1 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0330)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: E.coli; Immunogen sequence: H24-P97

Sensitivity

<1 pg/ml

Assay Range

15.6 pg/ml - 1,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK0330 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0330 is reactive to Ccl11 in Mouse samples

Validated Sample Types

cell culture supernatants, serum and plasma (citrate, EDTA).

Application Guarantee

EK0330 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of CCL11/Eotaxin

Eotaxin, also known as CCL11, is a potent inducer of eosinophil chemotaxis and is considered as a selective ligand of the CC chemokine receptor 3 (CCR3), which is expressed on eosinophils, basophils, and Th2 lymphocytes. Eotaxin is assumed to be involved in eosinophilic inflammatory diseases such as atopic dermatitis, allergic rhinitis, asthma and parasitic infections. The gene maps to chromosome 17 and is expressed constitutively at high levels in small intestine and colon, and at lower levels in various other tissues. The deduced mature protein sequence is 66% identical to human monocyte chemoattractant protein-1, and 60% identical to guinea pig eotaxin.

Kit Components

Catalog Number Description Quantity
EK0330-CAP Anti-Mouse Ccl11 Pre-coated 96-well strip microplate 1
EK0330-ST Mouse Ccl11 Standard 2 vials, 10 ng/tube
EK0330-DA Mouse Ccl11 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015.631.262.51252505001000
O.D.0.0640.1930.3310.5250.9901.3751.6781.952

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect CCL11/Eotaxin, Dilution ratio of 1:10, concentration in serum and plasma is around 1 ng/ml..

Some articles we found to cite concentrations of CCL11/Eotaxin in samples: 12743570 (Pubmed IDs).

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse Eotaxin-1 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)3422340533223429
Standard deviation1.4911.5926.4%22.0712.7133.46
CV (%)4.4%5.2%6.4%5.7%%5.7%7.8%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of CCL11/Eotaxin in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 134363836361.413.9%
Sample 22232272172192213.841.7%
Sample 34054124154224136.11.4%
*number of samples for each test n=16.

Gene/Protein Information For Ccl11 (Source: Uniprot.Org, NCBI)

Gene Name

Ccl11

Full Name

Eotaxin

Weight

10893 MW

Superfamily

intercrine beta (chemokine CC) family

Alternative Names

Eotaxin;C-C motif chemokine 11;Eosinophil chemotactic protein;Small-inducible cytokine A11;Ccl11;Scya11; CCL11 SCYA11 C-C motif chemokine ligand 11 eotaxin|chemokine (C-C motif) ligand 11|eosinophil chemotactic protein|eotaxin-1|small inducible cytokine subfamily A (Cys-Cys), member 11 (eotaxin)

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on Ccl11, check out the Ccl11 Infographic

Ccl11 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for Ccl11: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK0330 has been cited in 4 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

IL‑37 relieves allergic inflammation by inhibiting the CCL11 signaling pathway in a mouse model of allergic rhinitis

Systemic delivery of TNF-armed myxoma virus plus immune checkpoint inhibitor eliminates lung metastatic mouse osteosarcoma

Catalpol alleviates ovalbumin-induced asthma in mice: Reduced eosinophil infiltration in the lung

Li L, Yu Ch, Ying Hz, Yu Jm. J Ethnopharmacol. 2013 May 2;147(1):238-44. Doi: 10.1016/J.Jep.2013.03.012. Epub 2013 Mar 15. Antiviral Effects Of Modified Dingchuan Decoction Against Respiratory Syncytial Virus Infection In Vitro And In An Immunosup...

Have you used Mouse Eotaxin-1 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Mouse Eotaxin-1 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

7 Customer Q&As for Mouse Eotaxin-1 ELISA Kit PicoKine®

Question

Q: can you tell me how to prepare cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2019-06-22

Answer

A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are included in the product insert. Components in lysate and lysis buffer can impact immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2019-06-22

Question

Q: What is the optimal O.D. value for CCL11 ELISA kit? I performed your CCL11 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain CCL11 even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2019-02-26

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. regarding your assay, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this CCL11 ELISA kit to have sensitivity of 1pg/ml, that means the minimum amount of CCL11 that can be declared/interpreted as positive by the above standard is 1pg/ml.

Boster Scientific Support

Answered: 2019-02-26

Question

Q: if the enzyme conjugated CCL11 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the CCL11 antigen?

Verified Customer

Verified customer

Asked: 2018-09-22

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2018-09-22

Question

Q: how to analyze ELISA data? I measured CCL11 level in plasma.

Verified Customer

Verified customer

Asked: 2018-05-20

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2018-05-20

Question

Q: we need your recommendation regarding the dilution ratio of serum samples for detection of CCL11 in Mouse plasma? I am trying to measure a few parameters and it requires 100ul of diluted samples for each well. We have limited sample quantitys so we like to dilute as much as possible.

B. Thompson

Verified customer

Asked: 2017-08-28

Answer

A: without having an understanding the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CCL11 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2017-08-28

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2016-11-26

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2016-11-26

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2014-12-11

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is needed for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2014-12-11

$499
In stock, 2 left.

Order within 0 hours and 13 minutes to receive by Fri Nov 22

Get A Quote
In stock
Order Product
EK0330
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.