Product Info Summary
SKU: | EK2120 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Rat |
Application: | ELISA |
Sample Types: | cell culture supernatants, serum and plasma (heparin, EDTA, citrate). |
Product info
Product Name
Rat Crossveinless-2/CV-2/BMPER ELISA Kit PicoKine®
View all Crossveinless-2/CV-2/BMPER ELISA kits
SKU/Catalog Number
EK2120
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Rat Crossveinless-2/CV-2/BMPER ELISA Kit PicoKine® (96 Tests). Quantitate Rat Bmper in cell culture supernatants, serum and plasma (heparin, EDTA, citrate). Sensitivity: 50pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Rat Crossveinless-2/CV-2/BMPER ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK2120)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: V34-R685
Sensitivity
<50 pg/ml
Assay Range
62.5 pg/ml - 4,000 pg/ml
Standard Dilution Instructions
See datasheet of EK2120 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK2120 is reactive to Bmper in Rat samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin, EDTA, citrate).
Application Guarantee
EK2120 is guaranteed for ELISA in Rat by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of Crossveinless-2/CV-2/BMPER
This gene encodes a secreted protein that interacts with, and inhibits bone morphogenetic protein (BMP) function. It has been shown to inhibit BMP2- and BMP4-dependent osteoblast differentiation and BMP-dependent differentiation of the chondrogenic cells. Mutations in this gene are associated with a lethal skeletal disorder, diaphanospondylodysostosis.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK2120-CAP | Anti-Rat Bmper Pre-coated 96-well strip microplate | 1 |
EK2120-ST | Rat Bmper Standard | 2 vials, 10 ng/tube |
EK2120-DA | Rat Bmper Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 62.5 | 125 | 250 | 500 | 1000 | 2000 | 4000 |
O.D. | 0.068 | 0.172 | 0.254 | 0.376 | 0.612 | 0.922 | 1.524 | 2.089 |
Data Example Images
Click image to see more details
Rat BMPER PicoKine ELISA Kit Standard Curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect Crossveinless-2/CV-2/BMPER, Dilution ratio of 1:1, concentration in serum and plasma is less than the lowest standard, 62.5 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Rat Crossveinless-2/CV-2/BMPER ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 226 | 813 | 1749 | 235 | 854 | 1806 |
Standard deviation | 10.62 | 45.53 | 101.44 | 15.04 | 62.34 | 140.87 |
CV (%) | 4.7% | 5.6% | 5.8% | 6.4% | 7.3% | 7.8% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of Crossveinless-2/CV-2/BMPER in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 226 | 217 | 208 | 243 | 224 | 10.53 | 4.7% |
Sample 2 | 813 | 835 | 829 | 846 | 831 | 49.03 | 5.9% |
Sample 3 | 1749 | 1876 | 1816 | 1721 | 1791 | 110.98 | 6.2% |
Protein Target Info & Infographic
Gene/Protein Information For Bmper (Source: Uniprot.Org, NCBI)
Gene Name
Bmper
Full Name
BMP-binding endothelial regulator protein
Weight
76.148kDa
Alternative Names
BMP binding endothelial regulator; BMP-binding endothelial regulator precursor protein; BMP-binding endothelial regulator protein; BMPER; Bone morphogenetic protein-binding endothelial cell precursor-derived regulator; CRIM3; crossveinless 2; Crossveinless-2; CV2; CV-2; hCV2; KIAA1965; Protein crossveinless-2 Bmper|3110056H04Rik, CV-, CV-2, Cri, Crim3, Cv, Cv2|BMP-binding endothelial regulator|BMP-binding endothelial regulator protein|bone morphogenetic protein-binding endothelial cell precursor-derived regulator|crossveinless-2
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on Bmper, check out the Bmper Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for Bmper: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Rat Crossveinless-2/CV-2/BMPER ELISA Kit PicoKine® (EK2120)
Hello CJ!
No publications found for EK2120
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Rat Crossveinless-2/CV-2/BMPER ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Rat Crossveinless-2/CV-2/BMPER ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
8 Customer Q&As for Rat Crossveinless-2/CV-2/BMPER ELISA Kit PicoKine®
Question
Does EK2120 contain native human biological materials?
Verified customer
Asked: 2021-11-10
Answer
The Rat Crossveinless-2/CV-2/BMPER ELISA Kit PicoKine® (EK2120) doesn't contain native human biological materials.
Boster Scientific Support
Answered: 2021-11-11
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
Verified Customer
Verified customer
Asked: 2020-06-07
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is a must for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2020-06-07
Question
Q: can you suggest the dilution ratio of serum samples for detection of BMPER in Rat serum? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have low serum quantitys so we like to dilute as much as possible.
Verified Customer
Verified customer
Asked: 2019-07-02
Answer
A: unable to know the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the BMPER ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2019-07-02
Question
Q: how many samples can be assayed in a Picokine® ELISA Kit?
W. Evans
Verified customer
Asked: 2019-06-11
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2019-06-11
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
Verified Customer
Verified customer
Asked: 2018-12-05
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions
Boster Scientific Support
Answered: 2018-12-05
Question
Q: is it okay to use EDTA plasma as samples in Rat BMPER Picokine® ELISA Kit (Catalog # EK2120)?
Verified Customer
Verified customer
Asked: 2018-10-14
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can bind metal ions from the functional domain of BMPER causing degradation of its protein structure. BMPER may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes required for detection and block the antigen antibody reaction. We have tested the BMPER ELISA, treating samples with various anticoagulants and decided that heparin, EDTA or citrate can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2018-10-14
Question
Q: if the enzyme conjugated BMPER antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the BMPER antigen?
A. Garcia
Verified customer
Asked: 2018-01-09
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2018-01-09
Question
Q: how are cell lysates prepared for use in Picokine® ELISA kits?
Verified Customer
Verified customer
Asked: 2017-11-18
Answer
A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer may affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2017-11-18