Product Info Summary
SKU: | EK1992 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Human |
Application: | ELISA |
Sample Types: | cell culture supernatants, serum and plasma (heparin or EDTA) |
Product info
Product Name
Human GAS6 ELISA Kit PicoKine®
SKU/Catalog Number
EK1992
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human GAS6 ELISA Kit PicoKine® (96 Tests). Quantitate Human GAS6 in cell culture supernatants, serum and plasma (heparin or EDTA) . Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human GAS6 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1992)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: A49-A678
Sensitivity
<10 pg/ml
Assay Range
62.5 pg/ml - 4,000 pg/ml
Standard Dilution Instructions
See datasheet of EK1992 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK1992 is reactive to GAS6 in Human samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin or EDTA)
Application Guarantee
EK1992 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of GAS6
Growth arrest-specific 6, also known as GAS6, is a human gene coding for the Gas6 protein. It is mapped to 13q34. This gene encodes a gamma-carboxyglutamic acid (Gla)-containing protein thought to be involved in the stimulation of cell proliferation. This gene is frequently overexpressed in many cancers and has been implicated as an adverse prognostic marker. Elevated protein levels are additionally associated with a variety of disease states, including venous thromboembolic disease, systemic lupus erythematosus, chronic renal failure, and preeclampsia. Gas6 is a gamma-carboxyglutamic acid (Gla) domain-containing protein thought to be involved in the stimulation of cell proliferation.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK1992-CAP | Anti-Human GAS6 Pre-coated 96-well strip microplate | 1 |
EK1992-ST | Human GAS6 Standard | 2 vials, 10 ng/tube |
EK1992-DA | Human GAS6 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 62.5 | 125 | 250 | 500 | 1000 | 2000 | 4000 |
O.D. | 0.034 | 0.126 | 0.177 | 0.292 | 0.510 | 0.934 | 1.536 | 2.080 |
Data Example Images
Click image to see more details
Human GAS6 PicoKine ELISA Kit Standard Curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect GAS6, Dilution ratio of 1:10, concentration in serum and plasma is around 8 ng/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human GAS6 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 99 | 434 | 1403 | 119 | 482 | 1746 |
Standard deviation | 4.26 | 28.21 | 65.94 | 7.38 | 33.26 | 123.97 |
CV (%) | 4.3% | 6.5% | 4.7% | 6.2% | 6.9% | 7.1% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of GAS6 in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 99 | 92 | 101 | 100 | 98 | 3.53 | 3.6% |
Sample 2 | 434 | 424 | 411 | 459 | 432 | 17.59 | 4.0% |
Sample 3 | 1403 | 1407 | 1524 | 1413 | 1436 | 50.49 | 3.5% |
Protein Target Info & Infographic
Gene/Protein Information For GAS6 (Source: Uniprot.Org, NCBI)
Gene Name
GAS6
Full Name
Growth arrest-specific protein 6
Weight
74.925kDa
Alternative Names
Growth arrest-specific protein 6; GAS-6; AXL receptor tyrosine kinase ligand; GAS6; AXLLG GAS6 AXLLG, AXSF growth arrest specific 6 growth arrest-specific protein 6|AXL receptor tyrosine kinase ligand|AXL stimulatory factor
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on GAS6, check out the GAS6 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for GAS6: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Human GAS6 ELISA Kit PicoKine® (EK1992)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Human GAS6 ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Human GAS6 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
5 Customer Q&As for Human GAS6 ELISA Kit PicoKine®
Question
Q: if the enzyme conjugated GAS6 antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the GAS6 antigen?
Verified Customer
Verified customer
Asked: 2020-09-14
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2020-09-14
Question
Q: is it okay to use citrate plasma as samples in Human GAS6 Picokine® ELISA Kit (Catalog # EK1992)?
C. Edwards
Verified customer
Asked: 2020-04-22
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can irreversibly bind metal ions from the functional domain of GAS6 causing degradation of its protein structure. GAS6 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes needed for detection and block the antigen antibody reaction. We have tested the GAS6 ELISA, treating samples with different anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2020-04-22
Question
Q: we need your suggestion regarding the dilution ratio of serum samples for detection of GAS6 in Human plasma? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have limited sample volumes so we like to dilute as much as possible.
B. Hall
Verified customer
Asked: 2019-05-27
Answer
A: without knowing the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the GAS6 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2019-05-27
Question
Q: how to thaw whole blood sample for GAS6 ELISA after freezing?
S. Campbell
Verified customer
Asked: 2016-12-17
Answer
A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test GAS6 for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.
Boster Scientific Support
Answered: 2016-12-17
Question
Q: What is the optimal O.D. value for GAS6 ELISA kit? I used your GAS6 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain GAS6 even though the O.D. values are not very high?
D. Jha
Verified customer
Asked: 2016-08-30
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. a point of focus should be is whether your sample O.D. values are statistically significantly higher than your blank values. regarding your assay, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this GAS6 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of GAS6 that can be declared/interpreted as positive by the above standard is 10pg/ml.
Boster Scientific Support
Answered: 2016-08-30