Product Info Summary
SKU: | EK2076 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Mouse |
Application: | ELISA |
Sample Types: | cell culture supernatants, serum and plasma (heparin, EDTA, citrate). |
Product info
Product Name
Mouse GFRA3 ELISA Kit PicoKine®
View all GFR alpha-3/GDNF R alpha-3 ELISA kits
SKU/Catalog Number
EK2076
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Mouse GFRA3 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Gfra3 in cell culture supernatants, serum and plasma (heparin, EDTA, citrate). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Mouse GFRA3 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK2076)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: N29-N371
Sensitivity
<10 pg/ml
Assay Range
15.6 pg/ml - 1,000 pg/ml
Standard Dilution Instructions
See datasheet of EK2076 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK2076 is reactive to Gfra3 in Mouse samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin, EDTA, citrate).
Application Guarantee
EK2076 is guaranteed for ELISA in Mouse by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of GFR alpha-3/GDNF R alpha-3
GDNF family receptor alpha-3 (GFRα3), also known as the artemin receptor, is a protein that in humans is encoded by the GFRA3 gene. It is mapped to 18; 18 B1. The protein encoded by this gene is a glycosylphosphatidylinositol (GPI)-linked cell surface receptor and a member of the GDNF receptor family. It forms a signaling receptor complex with RET tyrosine kinase receptor and binds the ligand, artemin.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK2076-CAP | Anti-Mouse Gfra3 Pre-coated 96-well strip microplate | 1 |
EK2076-ST | Mouse Gfra3 Standard | 2 vials, 10 ng/tube |
EK2076-DA | Mouse Gfra3 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 15.6 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 |
O.D. | 0.036 | 0.144 | 0.245 | 0.468 | 0.821 | 1.315 | 1.908 | 2.241 |
Data Example Images
Click image to see more details
Mouse GFRA3 PicoKine ELISA Kit Standard Curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect GFR alpha-3/GDNF R alpha-3, Dilution ratio of 1:1, concentration in serum and plasma is around 30 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Mouse GFRA3 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 26 | 109 | 355 | 29 | 112 | 401 |
Standard deviation | 1.25 | 5.78 | 19.88 | 1.48 | 6.38 | 24.86 |
CV (%) | 4.8% | 5.3% | 5.6% | 5.1% | 5.7% | 6.2% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of GFR alpha-3/GDNF R alpha-3 in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 26 | 27 | 26 | 25 | 26 | 0.70 | 2.6% |
Sample 2 | 109 | 109 | 105 | 93 | 104 | 6.55 | 6.2% |
Sample 3 | 355 | 365 | 388 | 351 | 364 | 14.35 | 3.9% |
Protein Target Info & Infographic
Gene/Protein Information For Gfra3 (Source: Uniprot.Org, NCBI)
Gene Name
Gfra3
Full Name
GDNF family receptor alpha-3
Weight
44.511kDa
Superfamily
GDNFR family
Alternative Names
GDNF family receptor alpha-3; GDNF receptor alpha-3; GDNFR-alpha-3; GFR-alpha-3; Gfra3 GFRA3 GDNFR3 GDNF family receptor alpha 3 GDNF family receptor alpha-3|GDNF receptor alpha-3|GDNFR-alpha-3|GFR-alpha-3|GPI-linked receptor|glial cell line-derived neurotrophic factor receptor alpha-3
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on Gfra3, check out the Gfra3 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for Gfra3: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Mouse GFRA3 ELISA Kit PicoKine® (EK2076)
Hello CJ!
No publications found for EK2076
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Mouse GFRA3 ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Mouse GFRA3 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
10 Customer Q&As for Mouse GFRA3 ELISA Kit PicoKine®
Question
Q: how much samples can be assayed in a Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2020-12-17
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may depends upon the kit used so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2020-12-17
Question
Q: if the enzyme conjugated GFR alpha-3 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the GFR alpha-3 antigen?
Verified Customer
Verified customer
Asked: 2020-10-02
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2020-10-02
Question
Q: Can GFR alpha-3 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
Verified Customer
Verified customer
Asked: 2020-03-13
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2020-03-13
Question
Q: What is the optimal O.D. value for GFR alpha-3 ELISA kit? I used your GFR alpha-3 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain GFR alpha-3 even though the O.D. values are not very high?
Verified Customer
Verified customer
Asked: 2019-08-24
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. a point of focus should be is whether your sample O.D. values are statistically significantly higher than your blank values. regarding your assay, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this GFR alpha-3 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of GFR alpha-3 that can be declared/interpreted as positive by the above standard is 10pg/ml.
Boster Scientific Support
Answered: 2019-08-24
Question
Q: can I use EDTA plasma as samples in Mouse GFR alpha-3 Picokine® ELISA Kit (Catalog # EK2076)?
Verified Customer
Verified customer
Asked: 2019-08-02
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can attach metal ions from the functional domain of GFR alpha-3 causing disruption of its protein structure. GFR alpha-3 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes required for detection and block the antigen antibody reaction. We have tested the GFR alpha-3 ELISA, treating samples with a number of anticoagulants and decided that heparin, EDTA or citrate can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2019-08-02
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
Verified Customer
Verified customer
Asked: 2019-04-10
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2019-04-10
Question
Q: how to analyze ELISA data? I measured GFR alpha-3 level in serum.
Verified Customer
Verified customer
Asked: 2019-04-03
Answer
A: we recommend you this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. we also provide a convenient online tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online
Boster Scientific Support
Answered: 2019-04-03
Question
Q: can you recommend the dilution ratio of serum samples for detection of GFR alpha-3 in Mouse serum? I am trying to measure a multiple analytes and it requires 100ul of diluted samples for each well. We have low serum quantitys so we like to dilute as much as possible.
Verified Customer
Verified customer
Asked: 2018-05-14
Answer
A: unable to understand the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the GFR alpha-3 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2018-05-14
Question
Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for quantification GFR alpha-3 using the EK2076 Mouse GFR alpha-3 Picokine® ELISA Kit?
G. Walker
Verified customer
Asked: 2017-03-13
Answer
A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may affect the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples in order to prevent protein degradation.
Boster Scientific Support
Answered: 2017-03-13
Question
Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?
P. Johnson
Verified customer
Asked: 2015-10-01
Answer
A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer can have an affect on immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2015-10-01