Product Info Summary
SKU: | EK1577 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Mouse |
Application: | ELISA |
Sample Types: | cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). |
Product info
Product Name
Mouse CHL1/L1CAM-2 ELISA Kit PicoKine®
View all CHL-1/L1CAM-2 ELISA kits
SKU/Catalog Number
EK1577
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Mouse CHL1/L1CAM-2 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Chl1 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Mouse CHL1/L1CAM-2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1577)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: E26-W1083
Sensitivity
<10 pg/ml
Assay Range
156 pg/ml - 10,000 pg/ml
Standard Dilution Instructions
See datasheet of EK1577 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK1577 is reactive to Chl1 in Mouse samples
Validated Sample Types
cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).
Application Guarantee
EK1577 is guaranteed for ELISA in Mouse by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of CHL-1/L1CAM-2
Neural cell adhesion molecule L1-like protein also known as close homolog of L1 (CHL1) is a protein that in humans is encoded by the CHL1 gene. This protein is a member of the L1 gene family of neural cell adhesion molecules. By FISH, the CHL1 gene was mapped to chromosome 3p26.1. The protein however has dynamic localisation, meaning that it has not only multiple roles in the cell, but also various locations. This protein may also play a role in the growth of certain cancers.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK1577-CAP | Anti-Mouse Chl1 Pre-coated 96-well strip microplate | 1 |
EK1577-ST | Mouse Chl1 Standard | 2 vials, 10 ng/tube |
EK1577-DA | Mouse Chl1 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 156 | 312 | 625 | 125000 | 25000 | 5000 | 10000 |
O.D. | 0.003 | 0.084 | 0.144 | 0.268 | 0.522 | 0.945 | 1.719 | 2.493 |
Data Example Images
Click image to see more details
Mouse CHL1/L1CAM-2 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect CHL-1/L1CAM-2, Dilution ratio of 1:5, concentration in serum and plasma is 6-10 ng/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Mouse CHL1/L1CAM-2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 218 | 1822 | 4674 | 207 | 1753 | 4970 |
Standard deviation | 15.04 | 116.6 | 198.2% | 17.59 | 143.74 | 238.56 |
CV (%) | 6.9% | 6.4% | 4.2% | 8.5% | 8.2% | 4.8% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of CHL-1/L1CAM-2 in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 218 | 223 | 245 | 253 | 234 | 14.63 | 6.2% |
Sample 2 | 1822 | 1615 | 1911 | 1772 | 1780 | 107.48 | 6% |
Sample 3 | 4674 | 4640 | 4837 | 4877 | 4757 | 101.7 | 2.1% |
Protein Target Info & Infographic
Gene/Protein Information For Chl1 (Source: Uniprot.Org, NCBI)
Gene Name
Chl1
Full Name
Neural cell adhesion molecule L1-like protein
Weight
135074 MW
Superfamily
immunoglobulin superfamily
Alternative Names
Neural cell adhesion molecule L1-like protein;Cell adhesion molecule with homology to L1CAM;Chl1-like protein;Close homolog of L1;Processed neural cell adhesion molecule L1-like protein;Chl1;Call; CHL1 CALL, L1CAM2 cell adhesion molecule L1 like neural cell adhesion molecule L1-like protein|L1 cell adhesion molecule 2|cell adhesion molecule with homology to L1CAM (close homolog of L1)|cell adhesion molecule with homology to L1CAM (close homologue of L1)|close homolog of L1
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on Chl1, check out the Chl1 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for Chl1: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Mouse CHL1/L1CAM-2 ELISA Kit PicoKine® (EK1577)
Hello CJ!
No publications found for EK1577
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Mouse CHL1/L1CAM-2 ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Mouse CHL1/L1CAM-2 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
7 Customer Q&As for Mouse CHL1/L1CAM-2 ELISA Kit PicoKine®
Question
Q: Can CHL-1 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
Verified Customer
Verified customer
Asked: 2020-07-30
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2020-07-30
Question
Q: how many samples can be assayed in a Picokine® ELISA Kit?
M. Lewis
Verified customer
Asked: 2019-12-19
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2019-12-19
Question
Q: if the enzyme conjugated CHL-1 antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the CHL-1 antigen?
W. Parker
Verified customer
Asked: 2018-10-16
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2018-10-16
Question
Q: which procedure should I follow in order to thaw whole blood sample for CHL-1 ELISA after freezing?
P. Harris
Verified customer
Asked: 2018-05-25
Answer
A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test CHL-1 for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.
Boster Scientific Support
Answered: 2018-05-25
Question
Q: we need your suggestion regarding the dilution ratio of serum samples for detection of CHL-1 in Mouse plasma? I am trying to measure a few parameters and it requires 100ul of diluted samples for each well. We have low serum volumes so we like to dilute as much as possible.
Verified Customer
Verified customer
Asked: 2017-08-19
Answer
A: having little idea about the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CHL-1 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2017-08-19
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
Verified Customer
Verified customer
Asked: 2016-02-05
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is needed for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2016-02-05
Question
Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for analysis CHL-1 using the EK1577 Mouse CHL-1 Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2015-06-24
Answer
A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample immediately after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples in order to prevent protein degradation.
Boster Scientific Support
Answered: 2015-06-24