Human SDC1 / Syndecan-1 / CD138 ELISA Kit PicoKine®

Syndecan-1/CD138 ELISA kit for Human

Human SDC1 / Syndecan-1 / CD138 ELISA Kit PicoKine® (96 Tests). Quantitate Human SDC1 in cell culture supernatants and serum. Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays. Cited in 4 publication(s).

Product Info Summary

SKU: EK1339
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants and serum.

Product Name

Human SDC1 / Syndecan-1 / CD138 ELISA Kit PicoKine®

View all Syndecan-1/CD138 ELISA kits

SKU/Catalog Number

EK1339

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human SDC1 / Syndecan-1 / CD138 ELISA Kit PicoKine® (96 Tests). Quantitate Human SDC1 in cell culture supernatants and serum. Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human SDC1 / Syndecan-1 / CD138 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1339)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: NS0; Immunogen sequence: Q23-G254

Sensitivity

<10 pg/ml

Assay Range

312 pg/ml - 20,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK1339 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1339 is reactive to SDC1 in Human samples

Validated Sample Types

cell culture supernatants and serum.

Application Guarantee

EK1339 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of Syndecan-1/CD138

Syndecan 1, also known as SYND1 or CD138, is a protein which in humans is encoded by the SDC1 gene. The protein encoded by this gene is a transmembrane (type I) heparan sulfate proteoglycan and is a member of the syndecan proteoglycan family. This gene is mapped to 2p24.1. The syndecans mediate cell binding, cell signaling, cytoskeletal organization and syndecan receptors are required for internalization of the HIV-1 tat protein. The syndecan 1 protein functions as an integral membrane protein and participates in cell proliferation, cell migration and cell-matrix interactions via its receptor for extracellular matrix proteins. What’s more, Syndecan-1 is also a sponge for growth factors, with binding largely via heparan sulfate chains.

Kit Components

Catalog Number Description Quantity
EK1339-CAP Anti-Human SDC1 Pre-coated 96-well strip microplate 1
EK1339-ST Human SDC1 Standard 2 vials, 20 ng/tube
EK1339-DA Human SDC1 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)03126251250250050001000020000
O.D.0.0070.0550.1030.2010.3660.7461.2481.932

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect Syndecan-1/CD138, Dilution ratio of 1:1, concentration in serum is 68-5651 pg/ml..

Some articles we found to cite concentrations of Syndecan-1/CD138 in samples: 15089762 (Pubmed IDs).

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human SDC1 / Syndecan-1 / CD138 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)63225676839667626178785
Standard deviation26.51171.27545.7431.09196.27588.59
CV (%)4.1%6.6%6.5%4.6%7.5%6.7%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of Syndecan-1/CD138 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 163257160860460321.723.6%
Sample 2259525062397268625461074.2%
Sample 383968079930487378629453.895.2%
*number of samples for each test n=16.

Gene/Protein Information For SDC1 (Source: Uniprot.Org, NCBI)

Gene Name

SDC1

Full Name

Syndecan-1

Weight

32462 MW

Superfamily

syndecan proteoglycan family

Alternative Names

Syndecan-1;SYND1;CD138;SDC1;SDC; SDC1 CD138, SDC, SYND1, syndecan syndecan 1 syndecan-1|CD138 |heparan sulfate proteoglycan fibroblast growth factor receptor|syndecan proteoglycan 1

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on SDC1, check out the SDC1 Infographic

SDC1 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for SDC1: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK1339 has been cited in 4 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

Piperazine ferulate prevents high‑glucose‑induced filtration barrier injury of glomerular endothelial cells

Is all plasma created equal? A pilot study of the effect of interdonor variability

Qi F,Zhou H,Gu P,Tang ZH,Zhu BF,Chen JR,Zhang JS,Li F.Endothelial glycocalyx degradation is associated with early organ impairment in polytrauma patients.BMC Emerg Med.2021 Apr 20;21(1):52.doi:10.1186/s12873-021-00446-y.PMID:33879092;PMCID:PMC8056622.
Species: Human
EK1339 usage in article: APP:ELISA, SAMPLE:SERUM, DILUTION:NA

Feng Qi, Hao Zhou, Peng Gu et al. Endothelial Glycocalyx Degradation Is Associated With Early Organ Impairment in Multiple Trauma Patients, 17 March 2021, PREPRINT (Version 1) available at Research Square [https://doi.org/10.21203/rs.3.rs-303225/v1]
Species: Human
EK1339 usage in article: APP:ELISA, SAMPLE:SERUM, DILUTION:NA

Have you used Human SDC1 / Syndecan-1 / CD138 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Human SDC1 / Syndecan-1 / CD138 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

8 Customer Q&As for Human SDC1 / Syndecan-1 / CD138 ELISA Kit PicoKine®

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2020-11-14

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2020-11-14

Question

I did not get any measurable Syndecan-1 signal in my cell culture supernatants on ELISA but I expected some baseline signal even if it was small. Meanwhile, the standards worked fine, and I also confirmed cell activation by flow cytometry with ICAM-1. What happened? Any troubleshooting suggestions?

Verified Customer

Verified customer

Asked: 2020-05-01

Answer

Confirmed cell activation doesn't indicate the sample contains protein of interest. The protein may also be in small quantities beyond the ELISA detection range. To troubleshoot, we suggest that you try to increase the cell density and/or homogenize/lyse the cells in lysis buffer (instead of working with cell supernatant).

Boster Scientific Support

Answered: 2020-05-01

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2020-01-13

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may depends upon the kit used so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2020-01-13

Question

Q: What is the optimal O.D. value for CD138 ELISA kit? I used your CD138 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain CD138 even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2019-10-19

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. a point of focus should be is whether your sample O.D. values are statistically significantly higher than your blank values. considering your assay, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this CD138 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of CD138 that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2019-10-19

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2018-12-26

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2018-12-26

Question

Q: how are cell lysates prepared for use in Picokine® ELISA kits?

J. Zhou

Verified customer

Asked: 2018-05-25

Answer

A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are included in the product insert. Components in lysate and lysis buffer can effect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2018-05-25

Question

Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for analysis CD138 using the EK1339 Human CD138 Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2018-05-16

Answer

A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample immediately after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples in order to prevent protein degradation.

Boster Scientific Support

Answered: 2018-05-16

Question

Q: we need your recommendation regarding the dilution ratio of serum samples for detection of CD138 in Human serum? I am trying to measure a multiple analytes and it requires 100ul of diluted samples for each well. We have low serum quantitys so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2014-09-21

Answer

A: unable to know the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CD138 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2014-09-21

$499
In stock, 3+ left.

Order within 34 hours and 53 minutes to receive by Fri Nov 15

Get A Quote
In stock
Order Product
EK1339
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.