Human RET ELISA Kit PicoKine®

RET ELISA kit for Human

Human RET ELISA Kit PicoKine® (96 Tests). Quantitate Human RET in cell culture supernatants, serum and plasma (heparin). Sensitivity: 15pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Product Info Summary

SKU: EK1877
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin).

Product Name

Human RET ELISA Kit PicoKine®

View all RET ELISA kits

SKU/Catalog Number

EK1877

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human RET ELISA Kit PicoKine® (96 Tests). Quantitate Human RET in cell culture supernatants, serum and plasma (heparin). Sensitivity: 15pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human RET ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1877)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: NS0; Immunogen sequence: L29-R635

Sensitivity

<15 pg/ml

Assay Range

93.8 pg/ml - 6,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK1877 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1877 is reactive to RET in Human samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin).

Application Guarantee

EK1877 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of RET

This gene encodes a transmembrane receptor and member of the tyrosine protein kinase family of proteins. It is mapped to 10q11.21. Binding of ligands such as GDNF (glial cell-line derived neurotrophic factor) and other related proteins to the encoded receptor stimulates receptor dimerization and activation of downstream signaling pathways that play a role in cell differentiation, growth, migration and survival. The encoded receptor is important in development of the nervous system, and the development of organs and tissues derived from the neural crest. This proto-oncogene can undergo oncogenic activation through both cytogenetic rearrangement and activating point mutations. Mutations in this gene are associated with Hirschsprung disease and central hypoventilation syndrome and have been identified in patients with renal agenesis.

Kit Components

Catalog Number Description Quantity
EK1877-CAP Anti-Human RET Pre-coated 96-well strip microplate 1
EK1877-ST Human RET Standard 2 vials, 10 ng/tube
EK1877-DA Human RET Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)093.8187.5375750150030006000
O.D.0.0020.0680.1230.2450.4850.9071.4822.050

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect RET, Dilution ratio of 1:1, concentration in serum and plasma is around 500 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human RET ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)14862828131626912933
Standard deviation6.9632.03149.099.7244.92231.71
CV (%)4.7%5.1%5.3%6.0%6.5%7.9%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of RET in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 11481471531481492.341.5%
Sample 262865661166964122.793.5%
Sample 328133203328028373033210.196.9%
*number of samples for each test n=16.

Gene/Protein Information For RET (Source: Uniprot.Org, NCBI)

Gene Name

RET

Full Name

Proto-oncogene tyrosine-protein kinase receptor Ret

Weight

124.319kDa

Superfamily

protein kinase superfamily

Alternative Names

Proto-oncogene tyrosine-protein kinase receptor Ret; Cadherin family member 12; Proto-oncogene c-Ret; RET; CDHF12; CDHR16; PTC; RET51 RET CDHF12, CDHR16, HSCR1, MEN2A, MEN2B, MTC1, PTC-ELE1, RET ret proto-oncogene proto-oncogene tyrosine-protein kinase receptor Ret|RET receptor tyrosine kinase|cadherin family member 12|cadherin-related family member 16|proto-oncogene c-Ret|rearranged during transfection|ret proto-oncogene (multiple endocrine neoplasia and medullary thyroid carcinoma 1, Hirschsprung disease)

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on RET, check out the RET Infographic

RET infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for RET: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK1877

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Human RET ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Human RET ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

9 Customer Q&As for Human RET ELISA Kit PicoKine®

Question

Q: Can RET ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2020-05-27

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is needed. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2020-05-27

Question

Q: how to proceed with the analysis of ELISA data? I measured RET level in serum.

S. Surve

Verified customer

Asked: 2020-04-17

Answer

A: we recommend you this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. we also provide a convenient online tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2020-04-17

Question

Q: What is the optimal O.D. value for RET ELISA kit? I performed your RET ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain RET even though the O.D. values are not very high?

K. Kulkarni

Verified customer

Asked: 2019-12-05

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in the example mentioned, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this RET ELISA kit to have sensitivity of 15pg/ml, that means the minimum amount of RET that can be declared/interpreted as positive by the above standard is 15pg/ml.

Boster Scientific Support

Answered: 2019-12-05

Question

Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for quantification RET using the EK1877 Human RET Picokine® ELISA Kit?

H. Parker

Verified customer

Asked: 2019-07-17

Answer

A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may affect the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. avoid repeat freeze-thaw cycles with the stored samples in order to limit protein degradation.

Boster Scientific Support

Answered: 2019-07-17

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2018-11-26

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2018-11-26

Question

Q: how can I thaw whole blood sample for RET ELISA after freezing?

P. White

Verified customer

Asked: 2018-09-09

Answer

A: we do not recommend freezing and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test RET for a later time, you should let the blood clot in glass tubes and collect the serum to freeze for later use.

Boster Scientific Support

Answered: 2018-09-09

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2018-07-17

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2018-07-17

Question

Q: can you suggest the dilution ratio of serum samples for detection of RET in Human serum? I am trying to measure a a number of analytes and it requires 100ul of diluted samples for each well. We have limited sample quantitys so we like to dilute as much as possible.

D. Taylor

Verified customer

Asked: 2016-06-19

Answer

A: having little idea about the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the RET ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2016-06-19

Question

Q: is it okay to use EDTA plasma as samples in Human RET Picokine® ELISA Kit (Catalog # EK1877)?

W. Banerjee

Verified customer

Asked: 2015-05-19

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can irreversibly bind metal ions from the functional domain of RET causing degradation of its protein structure. RET may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes needed for detection and block the antigen antibody reaction. We have tested the RET ELISA, treating samples with a number of anticoagulants and decided that heparin can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2015-05-19

$499
In stock, 2 left.

Order within 34 hours and 48 minutes to receive by Fri Nov 15

Get A Quote
In stock
Order Product
EK1877
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.