Product Info Summary
SKU: | EK0912 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Human |
Application: | ELISA |
Sample Types: | cell culture supernatants, serum, plasma (heparin, EDTA) and urine. |
Product info
Product Name
Human CD23/FCER2 ELISA Kit PicoKine®
View all CD23/Fc epsilon RII ELISA kits
SKU/Catalog Number
EK0912
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human CD23/FCER2 ELISA Kit PicoKine® (96 Tests). Quantitate Human FCER2 in cell culture supernatants, serum, plasma (heparin, EDTA) and urine. Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human CD23/FCER2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0912)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: D48-S321
Sensitivity
<10 pg/ml
Assay Range
31.2 pg/ml - 2,000 pg/ml
Standard Dilution Instructions
See datasheet of EK0912 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0912 is reactive to FCER2 in Human samples
Validated Sample Types
cell culture supernatants, serum, plasma (heparin, EDTA) and urine.
Application Guarantee
EK0912 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of CD23/Fc epsilon RII
CD23, also known as Fc epsilon RII, or FcεRII, is the "low-affinity" receptor for IgE, an antibody isotype involved in allergy and resistance to parasites, and is important in regulation of IgE levels. There are two forms of CD23: CD23a and CD23b. CD23a is present on follicular B cells, whereas CD23b requires IL-4 to be expressed on T-cells, monocytes, Langerhans cells, eosinophils, and macrophages. As part of a mapping of multiple probes to specific bands on chromosome 19 by fluorescence in situ hybridization, the FCE2 gene was assigned to 19p13.3. CD23 (FCE2) is a key molecule for B-cell activation and growth. It is the low-affinity receptor for IgE. The truncated molecule can be secreted, then functioning as a potent mitogenic growth factor.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK0912-CAP | Anti-Human FCER2 Pre-coated 96-well strip microplate | 1 |
EK0912-ST | Human FCER2 Standard | 2 vials, 10 ng/tube |
EK0912-DA | Human FCER2 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 | 2000 |
O.D. | 0.047 | 0.112 | 0.151 | 0.276 | 0.509 | 0.905 | 1.549 | 2.294 |
Data Example Images
Click image to see more details
Human CD23/FCER2 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect CD23/Fc epsilon RII, Dilution ratio of 1:1, concentration in serum and plasma is 988-6030 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human CD23/FCER2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 61 | 194 | 981 | 55 | 207 | 899 |
Standard deviation | 2.8 | 7.95 | 64.74 | 3.41 | 9.93 | 71.02 |
CV (%) | 4.6% | 4.1% | 6.6% | 6.2% | 4.8% | 7.9% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of CD23/Fc epsilon RII in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 61 | 71 | 62 | 62 | 64 | 4.06 | 6.3% |
Sample 2 | 194 | 218 | 229 | 235 | 219 | 15.66 | 7.1% |
Sample 3 | 981 | 870 | 950 | 851 | 913 | 54.05 | 5.9% |
Protein Target Info & Infographic
Gene/Protein Information For FCER2 (Source: Uniprot.Org, NCBI)
Gene Name
FCER2
Full Name
Low affinity immunoglobulin epsilon Fc receptor
Weight
36299 MW
Alternative Names
Low affinity immunoglobulin epsilon Fc receptor ;FCER2 ; FCER2 BLAST-2, CD23, CD23A, CLEC4J, FCE2, IGEBF Fc fragment of IgE receptor II low affinity immunoglobulin epsilon Fc receptor|C-type lectin domain family 4, member J|CD23 |Fc epsilon receptor II|Fc fragment of IgE, low affinity II, receptor for (CD23)|fc-epsilon-RII|immunoglobulin E-binding factor|immunoglobulin epsilon-chain|lymphocyte IgE receptor
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on FCER2, check out the FCER2 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for FCER2: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Human CD23/FCER2 ELISA Kit PicoKine® (EK0912)
Hello CJ!
No publications found for EK0912
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Human CD23/FCER2 ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Human CD23/FCER2 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
9 Customer Q&As for Human CD23/FCER2 ELISA Kit PicoKine®
Question
Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for quantification CD23 using the EK0912 Human CD23 Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2020-11-16
Answer
A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples to prevent protein degradation.
Boster Scientific Support
Answered: 2020-11-16
Question
Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?
Verified Customer
Verified customer
Asked: 2019-12-09
Answer
A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are included in the product insert. Components in lysate and lysis buffer can change immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2019-12-09
Question
Q: how much samples can be assayed in a Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2019-05-16
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2019-05-16
Question
Q: What is the optimal O.D. value for CD23 ELISA kit? I performed your CD23 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain CD23 even though the O.D. values are not very high?
Verified Customer
Verified customer
Asked: 2019-04-22
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. a point of focus should be is whether your sample O.D. values are statistically significantly higher than your blank values. in the example mentioned, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this CD23 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of CD23 that can be declared/interpreted as positive by the above standard is 10pg/ml.
Boster Scientific Support
Answered: 2019-04-22
Question
Q: how to thaw whole blood sample for CD23 ELISA after freezing?
Verified Customer
Verified customer
Asked: 2018-08-26
Answer
A: we do not recommend freezing and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test CD23 for a later time, you should let the blood clot in glass tubes and collect the serum to freeze for later use.
Boster Scientific Support
Answered: 2018-08-26
Question
Q: if the enzyme conjugated CD23 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the CD23 antigen?
Z. Yang
Verified customer
Asked: 2017-04-11
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2017-04-11
Question
Q: can you suggest the dilution ratio of serum samples for detection of CD23 in Human plasma? I am trying to measure a a number of analytes and it requires 100ul of diluted samples for each well. We have low serum volumes so we like to dilute as much as possible.
W. Campbell
Verified customer
Asked: 2017-03-11
Answer
A: unable to understand the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CD23 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2017-03-11
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
V. Smith
Verified customer
Asked: 2016-07-30
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions
Boster Scientific Support
Answered: 2016-07-30
Question
Q: is it okay to use citrate plasma as samples in Human CD23 Picokine® ELISA Kit (Catalog # EK0912)?
Verified Customer
Verified customer
Asked: 2016-05-30
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can irreversibly bind metal ions from the functional domain of CD23 causing disruption of its protein structure. CD23 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes required for detection and block the antigen antibody reaction. We have tested the CD23 ELISA, treating samples with various anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2016-05-30