Human CCL21 / 6Ckine / Exodus 2 ELISA Kit PicoKine®

CCL21/6Ckine ELISA kit for Human

Human CCL21 / 6Ckine / Exodus 2 ELISA Kit PicoKine® (96 Tests). Quantitate Human CCL21 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 12pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays. Cited in 3 publication(s).

Product Info Summary

SKU: EK0555
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Human CCL21 / 6Ckine / Exodus 2 ELISA Kit PicoKine®

View all CCL21/6Ckine ELISA kits

SKU/Catalog Number

EK0555

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human CCL21 / 6Ckine / Exodus 2 ELISA Kit PicoKine® (96 Tests). Quantitate Human CCL21 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 12pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human CCL21 / 6Ckine / Exodus 2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0555)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: E.coli; Immunogen sequence: S24-P134

Sensitivity

<12 pg/ml

Assay Range

62.5 pg/ml - 4,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK0555 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0555 is reactive to CCL21 in Human samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK0555 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of CCL21/6Ckine

Chemokine (C-C motif) ligand 21 (CCL21) is a small cytokine belonging to the CC chemokine family. This chemokine is also known as 6Ckine (because it has six conserved cysteine residues instead of the four cysteines typical to chemokines), exodus-2, and secondary lymphoid-tissue chemokine (SLC). By somatic cell hybrid and radiation hybrid analyses, mapped the SCYA21 gene to 9p13. Chemokines are a family of proteins that direct leukocyte migration and activation to inflammatory stimuli. CXC chemokine ligand 13 (CXCL13), CC chemokine ligand 21 (CCL21), and CCL19 are constitutively expressed in secondary lymphoid organs, where they control the placement of lymphocytes and dendritic cells. It was demonstrate that the local expression of homeostatic chemokines in nonlymphoid organs, such as the lung, plays an important role in protective immune responses.

Kit Components

Catalog Number Description Quantity
EK0555-CAP Anti-Human CCL21 Pre-coated 96-well strip microplate 1
EK0555-ST Human CCL21 Standard 2 vials, 10 ng/tube
EK0555-DA Human CCL21 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)062.5125250500100020004000
O.D.0.0040.0360.0670.2540.3960.9701.6072.007

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect CCL21/6Ckine, Dilution ratio of 1:1, concentration in serum and plasma is around 500 pg/ml..

Some articles we found to cite concentrations of CCL21/6Ckine in samples: 25260647, 23764550 (Pubmed IDs).

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human CCL21 / 6Ckine / Exodus 2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)10070913521037061475
Standard deviation428.3682.476.931.7792.92
CV (%)4%4%6.1%6.7%4.5%6.3%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of CCL21/6Ckine in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 1100109108951035.785.6%
Sample 27096977067247099.721.3%
Sample 31352151714471423143458.954.1%
*number of samples for each test n=16.

Gene/Protein Information For CCL21 (Source: Uniprot.Org, NCBI)

Gene Name

CCL21

Full Name

C-C motif chemokine 21

Weight

14646 MW

Superfamily

intercrine beta (chemokine CC) family

Alternative Names

C-C motif chemokine 21;6Ckine;Beta-chemokine exodus-2;Secondary lymphoid-tissue chemokine;SLC;Small-inducible cytokine A21;CCL21;SCYA21;UNQ784/PRO1600; CCL21 6Ckine, CKb9, ECL, SCYA21, SLC, TCA4 C-C motif chemokine ligand 21 C-C motif chemokine 21|Efficient Chemoattractant for Lymphocytes|beta chemokine exodus-2|chemokine (C-C motif) ligand 21|secondary lymphoid tissue chemokine|small inducible cytokine subfamily A (Cys-Cys), member 21

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on CCL21, check out the CCL21 Infographic

CCL21 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for CCL21: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK0555 has been cited in 3 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

Lymphatic Metastasis of NSCLC Involves Chemotaxis Effects of Lymphatic Endothelial Cells through the CCR7–CCL21 Axis Modulated by TNF-α

Zhang S, Wang H, Xu Z, Bai Y, Xu L. Lymphatic Metastasis of NSCLC Involves Chemotaxis Effects of Lymphatic Endothelial Cells through the CCR7-CCL21 Axis Modulated by TNF-α. Genes (Basel). 2020 Nov 4;11(11):E1309. doi: 10.3390 /genes 11111309. PMID: 331581
Species: Human
EK0555 usage in article: APP:ELISA, SAMPLE:HLEC CELLS, DILUTION:NA

Low-dose paclitaxel improves the therapeutic efficacy of recombinant adenovirus encoding CCL21 chemokine against murine cancer

Have you used Human CCL21 / 6Ckine / Exodus 2 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Human CCL21 / 6Ckine / Exodus 2 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

10 Customer Q&As for Human CCL21 / 6Ckine / Exodus 2 ELISA Kit PicoKine®

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

C. Jackson

Verified customer

Asked: 2020-05-26

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2020-05-26

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2020-01-22

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2020-01-22

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

C. Roberts

Verified customer

Asked: 2020-01-13

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2020-01-13

Question

Q: What is the optimal O.D. value for CCL21 ELISA kit? I performed your CCL21 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain CCL21 even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2019-10-13

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. what you should focus on is whether your sample O.D. values are statistically significantly higher than your blank values. in the above example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this CCL21 ELISA kit to have sensitivity of 12pg/ml, that means the minimum amount of CCL21 that can be declared/interpreted as positive by the above standard is 12pg/ml.

Boster Scientific Support

Answered: 2019-10-13

Question

Q: we need your recommendation regarding the dilution ratio of serum samples for detection of CCL21 in Human serum? I am trying to measure a few parameters and it requires 100ul of diluted samples for each well. We have limited sample volumes so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2019-05-25

Answer

A: without having an understanding the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CCL21 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2019-05-25

Question

Q: Can CCL21 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2018-07-30

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please view the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2018-07-30

Question

Q: how are cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2018-07-26

Answer

A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate can be found in the product insert. Components in lysate and lysis buffer can impact immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2018-07-26

Question

Q: if the enzyme conjugated CCL21 antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the CCL21 antigen?

Verified Customer

Verified customer

Asked: 2018-07-22

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2018-07-22

Question

Q: how to analyze ELISA data? I have obtained CCL21 level in serum.

M. Parker

Verified customer

Asked: 2014-10-12

Answer

A: we recommend you this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2014-10-12

Question

Is this ELISA kit able to detect recombinant CCL21?

Verified Customer

Verified customer

Asked: 2014-02-10

Answer

Yes, this kit is able to detect recombinant CCL21 but this ability also depends on the recombinant protein itself.

Boster Scientific Support

Answered: 2014-02-10

$499
In stock, 2 left.

Order within 1 hours and 35 minutes to receive by Fri Nov 22

Get A Quote
In stock
Order Product
EK0555
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.