Product Info Summary
SKU: | EK0390 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Rat |
Application: | ELISA |
Sample Types: | cell culture supernatants and serum. |
Product info
Product Name
Rat IL-1 Alpha/IL-1F1/IL1A ELISA Kit PicoKine®
View all IL-1 alpha/IL-1F1 ELISA kits
SKU/Catalog Number
EK0390
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Rat IL-1 Alpha ELISA Kit PicoKine® (96 Tests). Quantitate Rat Il1a in cell culture supernatants and serum. Sensitivity: 0.5pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Rat IL-1 Alpha/IL-1F1/IL1A ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0390)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: E.coli; Immunogen sequence: S115-S270
Sensitivity
<0.5 pg/ml
Assay Range
4.69 pg/ml - 300 pg/ml
Standard Dilution Instructions
See datasheet of EK0390 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0390 is reactive to Il1a in Rat samples
Validated Sample Types
cell culture supernatants and serum.
Application Guarantee
EK0390 is guaranteed for ELISA in Rat by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of IL-1 alpha/IL-1F1
Interleukin-1 alpha (IL-1 alpha) and interleukin-1 beta (IL-1 beta) are two biochemically distinct, but distantly related, polypeptidic cytokines that play a key role in inflammation, immunologic reactions, and tissue repair. IL-1 alpha has been implicated in the pathogenesis of infectious, autoimmune and inflammatory diseases. Recently, it has been shown that IL-1 alpha is identical to hematopoietin 1, which is described as a hematopoietic growth factor acting on early progenitor cells in synergy with other hematopoietic growth factors.1 The human interleukin 1 alpha gene is assigned to chromosome 2. Genetic polymorphisms at interleukin (IL)-1alpha and IL-1beta have been recently suggested to be associated with severity of adult periodontitis. The murine IL-1 alpha and IL-1 beta genes encode structurally and evolutionarily related cytokines that exert a regulatory role in numerous physiological processes including hemopoiesis. The standard product used in this kit is recombinant rat IL-1alpha with the molecular mass of 18kDa.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK0390-CAP | Anti-Rat Il1a Pre-coated 96-well strip microplate | 1 |
EK0390-ST | Rat Il1a Standard | 2 vials, 10 ng/tube |
EK0390-DA | Rat Il1a Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 4.69 | 9.4 | 18.8 | 37.5 | 75 | 150 | 300 |
O.D. | 0.072 | 0.146 | 0.217 | 0.349 | 0.449 | 0.678 | 1.090 | 1.834 |
Data Example Images
Click image to see more details
Rat IL-1 alpha PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect IL-1 alpha/IL-1F1, Dilution ratio of 1:1, concentration in serum is less than the lowest standard, 12.5 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Rat IL-1 Alpha/IL-1F1/IL1A ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 15 | 40 | 131 | 14 | 43 | 120 |
Standard deviation | 1.06 | 2.12 | 9.69 | 1.09 | 2.58 | 10.8 |
CV (%) | 7.1% | 5.3% | 7.4% | 7.8% | 6% | 9% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of IL-1 alpha/IL-1F1 in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 15 | 16 | 15 | 17 | 15 | 0.82 | 5.4% |
Sample 2 | 40 | 39 | 46 | 45 | 42 | 3.04 | 7.2% |
Sample 3 | 131 | 123 | 146 | 136 | 134 | 8.33 | 6.2% |
Protein Target Info & Infographic
Gene/Protein Information For Il1a (Source: Uniprot.Org, NCBI)
Gene Name
Il1a
Full Name
Interleukin-1 alpha
Weight
30856 MW
Superfamily
IL-1 family
Alternative Names
Interleukin-1 alpha;IL-1 alpha;Il1a; IL1A IL-1 alpha, IL-1A, IL1, IL1-ALPHA, IL1F1 interleukin 1 alpha interleukin-1 alpha|hematopoietin-1|preinterleukin 1 alpha|pro-interleukin-1-alpha
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on Il1a, check out the Il1a Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for Il1a: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Rat IL-1 Alpha/IL-1F1/IL1A ELISA Kit PicoKine® (EK0390)
Hello CJ!
EK0390 has been cited in 21 publications:
*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.
Promotion of chemerin in rat diabetic kidney disease through enhancement of TGF-β1/Smads/CTGF pathway
Inhibitory Effects of Angelica Polysaccharide on Activation of Mast Cells
The inhibitory effects of Qingchang Wenzhong granule on the interactive network of inflammation, oxidative stress, and apoptosis in rats with dextran sulfate sodium‐induced colitis
Protective effect of ginsenoside Rg3 on lung injury in diabetic rats
Li Y, Wang N, Ma Z, Wang Y, Yuan Y, Zhong Z, Hong Y, Zhao M. Lipoxin A4 protects against paraquat‑induced acute lung injury by inhibiting the TLR4/MyD88‑mediated activation of the NF‑κB and PI3K/AKT pathways. Int J Mol Med. 2021 May;47(5):86. doi: 10.3892/ijmm. 2021.4919. Epub 2021 Mar 24. PMID: 33760150.
Species: Mouse,Rat
EK0390 usage in article: APP:ELISA, SAMPLE:BALF AND RAW264.7 CELL, DILUTION:NA
He C,Su C,Zhang W,Zhou Q,Shen X,Yang J,Shi N.Modulatory Potential of LncRNA Zfas1 for Inflammation and Neuronal Apoptosis in Temporal Lobe Epilepsy.Yonsei Med J.2021 Mar;62(3):215-223.doi:10.3349/ymj.2021.62.3.215.PMID:33635011.
Species: Human,Rat
EK0390 usage in article: APP:ELISA, SAMPLE:NEURON, DILUTION:NA
Urinary brain-derived neurotrophic factor: a potential biomarker for objective diagnosis of overactive bladder
Cytokine Attenuation and Free Radical Scavenging Activity of a New Flavanone7,4?-Dihydroxy-3?,3?-Dimethyl -(5,6-Pyrano-2?-One)- 8- (3?,3?-Dimethyl Allyl)- Isolated from Mallotus philippensis: Possible Mechanism for Its Anti-Inflammatory Activity
Inhibitory Effects of Angelica Polysaccharide on Activation of Mast Cells
Suppression of complete Freund's adjuvant-induced adjuvant arthritis by cobratoxin
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Rat IL-1 Alpha/IL-1F1/IL1A ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Rat IL-1 Alpha/IL-1F1/IL1A ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
6 Customer Q&As for Rat IL-1 Alpha/IL-1F1/IL1A ELISA Kit PicoKine®
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
Verified Customer
Verified customer
Asked: 2019-11-20
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is needed for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2019-11-20
Question
Q: What is the optimal O.D. value for IL-1 alpha ELISA kit? I performed your IL-1 alpha ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain IL-1 alpha even though the O.D. values are not very high?
Verified Customer
Verified customer
Asked: 2019-07-05
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. considering your assay, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this IL-1 alpha ELISA kit to have sensitivity of 0.5pg/ml, that means the minimum amount of IL-1 alpha that can be declared/interpreted as positive by the above standard is 0.5pg/ml.
Boster Scientific Support
Answered: 2019-07-05
Question
Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for measurement IL-1 alpha using the EK0390 Rat IL-1 alpha Picokine® ELISA Kit?
D. Rodriguez
Verified customer
Asked: 2019-02-10
Answer
A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample on priority basis collection when possible, or aliquot into single use volumes and store samples frozen. avoid repeat freeze-thaw cycles with the stored samples to prevent protein degradation.
Boster Scientific Support
Answered: 2019-02-10
Question
Q: Can IL-1 alpha ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
S. Mehta
Verified customer
Asked: 2017-01-08
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is a must. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2017-01-08
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
Verified Customer
Verified customer
Asked: 2016-04-29
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions
Boster Scientific Support
Answered: 2016-04-29
Question
Q: how many samples can be assayed in a Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2014-03-09
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2014-03-09