Product Info Summary
SKU: | EK1574 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Rat |
Application: | ELISA |
Sample Types: | cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). |
Product info
Product Name
Rat Angiopoietin-2 ELISA Kit PicoKine®
View all Angiopoietin-2 ELISA kits
SKU/Catalog Number
EK1574
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Rat Angiopoietin-2 ELISA Kit PicoKine® (96 Tests). Quantitate Rat Angpt2 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 15pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Rat Angiopoietin-2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1574)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: Y19-F496
Sensitivity
<15 pg/ml
Assay Range
156 pg/ml - 10,000 pg/ml
Standard Dilution Instructions
See datasheet of EK1574 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK1574 is reactive to Angpt2 in Rat samples
Validated Sample Types
cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).
Application Guarantee
EK1574 is guaranteed for ELISA in Rat by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of Angiopoietin-2
Angiopoietin-2 is a protein that in humans is encoded by the ANGPT2 gene. Angiopoietins are members of the vascular endothelial growth factor family and the only known growth factors largely specific for vascular endothelium. ANGPT2 is a naturally occurring antagonist of angiopoietin-1 that competes for binding to the TIE2 receptor and blocks ANGPT1-induced TIE2 autophosphorylation during vasculogenesis. Its expression occurs at sites of vascular remodelling: dorsal aorta and major aortic branches, ovary, placenta and uterus.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK1574-CAP | Anti-Rat Angpt2 Pre-coated 96-well strip microplate | 1 |
EK1574-ST | Rat Angpt2 Standard | 2 vials, 10 ng/tube |
EK1574-DA | Rat Angpt2 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 156 | 312 | 625 | 1250 | 2500 | 5000 | 10000 |
O.D. | 0.032 | 0.143 | 0.143 | 0.248 | 0.423 | 0.816 | 1.359 | 2.031 |
Data Example Images
Click image to see more details
Rat Angiopoietin-2 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect Angiopoietin-2, Dilution ratio of 1:5, concentration in serum and plasma is 4-6 ng/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Rat Angiopoietin-2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 253 | 1986 | 5096 | 239 | 1814 | 4721 |
Standard deviation | 19.98 | 99.3 | 229.32 | 22.22 | 121.53 | 231.32 |
CV (%) | 7.9% | 5% | 4.5% | 9.3% | 6.7% | 4.9% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of Angiopoietin-2 in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 253 | 256 | 215 | 222 | 236 | 18.2 | 7.7% |
Sample 2 | 1986 | 2081 | 1801 | 1998 | 1966 | 102.31 | 5.2% |
Sample 3 | 5096 | 4569 | 4759 | 5117 | 4885 | 231.34 | 4.7% |
Protein Target Info & Infographic
Gene/Protein Information For Angpt2 (Source: Uniprot.Org, NCBI)
Gene Name
Angpt2
Full Name
Angiopoietin-2
Weight
56518 MW
Alternative Names
Angiopoietin-2;ANG-2;Angpt2;Agpt2; ANGPT2 AGPT2, ANG2 angiopoietin 2 angiopoietin-2|Tie2-ligand|angiopoietin-2B|angiopoietin-2a
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on Angpt2, check out the Angpt2 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for Angpt2: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Rat Angiopoietin-2 ELISA Kit PicoKine® (EK1574)
Hello CJ!
EK1574 has been cited in 4 publications:
*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.
Angiotensin II type 1 receptor blockade attenuates posttraumatic stress disorder-related chronic pain by inhibiting glial activation in the spinal cord
Zhang, P., Peng, J., Ren, Y., Zheng, H., & Yan, H.(2021).Dexmedetomidine protects against endothelial injury in septic rats induced by cecal ligation and puncture by decreasing angiopoietin 2 and increasing vascular endothelial cadherin levels.Experimenta
Species: Rat
EK1574 usage in article: APP:ELISA, SAMPLE:PLASMA, DILUTION:NA
Autonomic remodeling may be responsible for decreased incidence of aortic dissection in STZ-induced diabetic rats via down-regulation of matrix metalloprotease 2
Cai W, Zhang Z, Huang Y, Sun H, Qiu L. Exp Ther Med. 2018 Jan;15(1):924-932. doi: 10.3892/etm.2017.5442. Epub 2017 Nov 6. Vaccarin alleviates hypertension and nephropathy in renovascular hypertensive rats
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Rat Angiopoietin-2 ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Rat Angiopoietin-2 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
9 Customer Q&As for Rat Angiopoietin-2 ELISA Kit PicoKine®
Question
Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for measurement Angiopoietin-2 using the EK1574 Rat Angiopoietin-2 Picokine® ELISA Kit?
Verified Customer
Verified customer
Asked: 2020-07-17
Answer
A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample on priority basis collection when possible, or aliquot into single use volumes and store samples frozen. avoid repeat freeze-thaw cycles with the stored samples in order to prevent protein degradation.
Boster Scientific Support
Answered: 2020-07-17
Question
Q: can I use citrate plasma as samples in Rat Angiopoietin-2 Picokine® ELISA Kit (Catalog # EK1574)?
L. Perez
Verified customer
Asked: 2020-07-11
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can sequester metal ions from the functional domain of Angiopoietin-2 causing degradation of its protein structure. Angiopoietin-2 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the Angiopoietin-2 ELISA, treating samples with a number of anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2020-07-11
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
Verified Customer
Verified customer
Asked: 2019-05-19
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions
Boster Scientific Support
Answered: 2019-05-19
Question
Q: how are cell lysates prepared for use in Picokine® ELISA kits?
H. Huang
Verified customer
Asked: 2019-02-15
Answer
A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer can change immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2019-02-15
Question
Q: if the enzyme conjugated Angiopoietin-2 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the Angiopoietin-2 antigen?
Verified Customer
Verified customer
Asked: 2018-05-19
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2018-05-19
Question
Q: how to thaw whole blood sample for Angiopoietin-2 ELISA after freezing?
M. Campbell
Verified customer
Asked: 2018-02-09
Answer
A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test Angiopoietin-2 for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.
Boster Scientific Support
Answered: 2018-02-09
Question
Q: how much samples can be assayed in a Picokine® ELISA Kit?
R. Campbell
Verified customer
Asked: 2017-04-14
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may depends upon the kit used so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2017-04-14
Question
Q: Can Angiopoietin-2 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
A. Yang
Verified customer
Asked: 2016-03-01
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is a must. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please view the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2016-03-01
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
Verified Customer
Verified customer
Asked: 2014-08-09
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2014-08-09