Multiplex ELISA Kit For Human Cytokine - Stripwells (16-plex)

ELISA kit for Multiplex detection

The Multiplex Human Cytokine – Stripwells (16-plex) is a fully quantitative ELISA-based chemiluminescent assay allowing the concurrent measurement of 16 biomarkers or analytes: IFNγ, IL-1α, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-8, IL-10, IL-12p70, IL-13, IL-15, IL-17A, IL-23, TNFα, TNFβ. Attention: This product is from Quansys Bio and requires a special plate reader. Please make sure you have the proper equipment before ordering. For details, please contact [email protected].

Product Info Summary

Species: Human
Sample Type: Serum, EDTA/Heparin Plasma
Volume Required per Well: Min 25 µl
Assay Length: 2.25 hours
Specificity: All analytes < 1% intra-panel cross-reactivity
Assay Type: Planar Based Multiplexed ELISA
Detection Method: Chemiluminescent
Multiplex Format: 96-well solid plate
Catalog: MEK1001
Manufacturer Reference Number: 110333HU
Analytes:IFNγ, IL-1α, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-8, IL-10, IL-12p70, IL-13, IL-15, IL-17A, IL-23, TNFα, TNFβ

Product Overview

The Multiplex Human Cytokine – Stripwells (16-plex) is a fully quantitative ELISA-based chemiluminescent assay allowing the concurrent measurement of 16 biomarkers or analytes. Using only 25 µl of sample per well, up to 80 samples can be assayed for all 16 markers in the panel within 2.25 hours.

The Multiplex Human Cytokine HS Screen (15-Plex) provides researchers an easy to use and cost-effective means of generating a cytokine profile for each sample. Multiplex plates are built by adsorbing 16 distinct capture antibodies in a defined array to the bottom of each well. Our high-quality reagents help ensure the accuracy of your results.

Assay Ranges

AnalyteAssay TypeCalibrator RangeUpper Limit of Quantification (ULOQ)Lower Limit of Quantification (LLOQ)Limit of Detection
IFNγSandwich 8000 -10.97 (pg/mL)5600 (pg/mL)14.3 (pg/mL)4.95 (pg/mL)
IL-1αSandwich 4000 -5.49 (pg/mL) 2800 (pg/mL)7.1 (pg/mL)5.43 (pg/mL)
IL-1βSandwich 12226 -16.77 (pg/mL)8558 (pg/mL)21.8 (pg/mL)12.40 (pg/mL)
IL-2Sandwich5213 – 7.15 (pg/mL)3649 (pg/mL)9.3 (pg/mL)4.12 (pg/mL)
IL-4Sandwich1676 – 2.30 (pg/mL)1173 (pg/mL)3.0 (pg/mL)1.79 (pg/mL)
IL-5Sandwich3000 – 4.12 (pg/mL)2100 (pg/mL)5.3 (pg/mL)2.90 (pg/mL)
IL-6Sandwich3000 – 4.12 (pg/mL)2100 (pg/mL)5.3 (pg/mL) 3.47 (pg/mL)
IL-8Sandwich2000 – 2.74 (pg/mL)1400 (pg/mL)3.6 (pg/mL)1.37 (pg/mL)
IL-10Sandwich8039 – 11.03 (pg/mL)5627 (pg/mL)14.3 (pg/mL)10.99 (pg/mL)
IL-12p70Sandwich3000 – 4.12 (pg/mL)2100 (pg/mL)5.3 (pg/mL) 3.20 (pg/mL)
IL-13Sandwich3000 – 4.12 (pg/mL)2100 (pg/mL)5.3 (pg/mL)4.12 (pg/mL)
IL-15Sandwich 10733 – 14.72 (pg/mL)7513 (pg/mL)19.1 (pg/mL)6.87 (pg/mL)
IL-17ASandwich16772 – 23.01 (pg/mL)11740 (pg/mL)29.9 (pg/mL)22.57 (pg/mL)
IL-23Sandwich41700 – 57.20 (pg/mL)21000 (pg/mL)120 (pg/mL)48.65 (pg/mL)
TNFαSandwich 6500 – 8.92 (pg/mL)4522 (pg/mL)11.5 (pg/mL)7.74 (pg/mL)
TNFβSandwich4000 – 5.49 (pg/mL)2800 (pg/mL)7.1 (pg/mL)5.29 (pg/mL)

Kit Components

Each kit contains a 96-well plate (solid plate), with relevant biomarker panel in each well, and contains all reagents required to perform testing. If you want a strip-well format, please contact us for customization.

Reagents Include:

Calibrator: Lyophilized, recombinant antigens in a buffered protein base
Detection Mix: Liquid, 6 mL/vial of biotinylated antibodies in a buffered protein solution with preservatives
Substrate A: Liquid, 3 mL/vial of stabilized hydrogen peroxide
Substrate B: Liquid, 3 mL/vial of stabilized signal enhancer
Sample Diluents: Liquid, 10 mL/vial of a buffered protein solution with heterophilic antibody and rheumatoid factor blockers and preservatives
Streptavidin HRP (1X): Liquid, 6 mL/vial of streptavidin-conjugated horseradish peroxidase
Wash Buffer (20X): Liquid, 50 mL/vial of a concentrated solution of buffered surfactant
Plate Seals (3): Adhesive strips

Product Images

Hello CJ!

No publications found for MEK1001

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Multiplex ELISA Kit For Human Cytokine - Stripwells (16-plex)?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Multiplex ELISA Kit For Human Cytokine - Stripwells (16-plex)

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

6 Customer Q&As for Multiplex ELISA Kit For Human Cytokine - Stripwells (16-plex)

Question

Can bioteck plate reader be used for Multiplex ELISA Kit For Human Cytokine - Stripwells (16-Plex) (MEK1001)?

Verified customer

Asked: 2022-03-24

Answer

The minimum qualifications that the imager must meet to be able to image our plates are the following: 1. The imager has a light‐tight imaging chamber, a non‐illumination or chemi-luminescent mode, and can export grayscale 16‐bit TIFF files. 2. Camera‐based imagers must also have at least 1 MP resolution (4+ MP, flat‐field correction, and a cooled sensor is preferred). 3. In addition, the device must also be able to export grayscale 16-bit TIFF files. We require that customers purchase an additional substrate vial for third party imagers. If the customer will not be using a Q-View imager in the future, they need to purchase an additional substrate vial.

Boster Scientific Support

Answered: 2022-03-24

Question

Is it possible to use cell culture supernatants as the sample type for MEK1001?

Verified customer

Asked: 2020-12-18

Answer

Yes, you can use cell culture supernatants on the Multiplex ELISA Kit For Human Cytokine - Stripwells (16-Plex) (MEK1001).

Boster Scientific Support

Answered: 2020-12-21

Question

What kind of plate reader does MEK1001 require?

Verified customer

Asked: 2020-12-18

Answer

The Multiplex ELISA Kit For Human Cytokine - Stripwells (16-Plex) (MEK1001) is built to be used with Q-View imagers.

Boster Scientific Support

Answered: 2020-12-21

Question

Can those buffers in MEK1001 use separation and do independent experiment different times?

Verified customer

Asked: 2020-06-20

Answer

Yes, there are three separate vials that the customer would reconstitute one at a time as they need to use them. There are enough reagents to run the Multiplex ELISA Kit For Human Cytokine - Stripwells (16-Plex) (MEK1001) kit three different times.

Boster Scientific Support

Answered: 2020-06-23

Question

What plate reader is needed for the MEK1001 kit? Is this compatible with BioTek Synergy HT?

Verified customer

Asked: 2019-12-18

Answer

We do not support third party imagers and since there are so many models to keep track of, we are not certain which ones are compatible with our kits. The following are the requirements for a third party imager to be compatible with our plates: -The imager should have a light‐tight imaging chamber, a non‐illumination or chemi-luminescent mode, and can export grayscale 16‐bit TIFF files. -Camera‐based imagers must also have at least 1 MP resolution (4+ MP, flat‐field correction, and a cooled sensor is preferred).

Boster Scientific Support

Answered: 2019-12-23

Question

Does the MEK1001 kit come with any analysis software or is it not needed?

Verified customer

Asked: 2019-12-18

Answer

Unforunately not. The software must be purchased for $1,980 for long-term use (license does not expire). A free 60 day trial can be downloaded once you purchase the product.

Boster Scientific Support

Answered: 2019-12-23

Plate Reader Option

Total: $2805

SKU:MEK1001

In stock, 3+ left.

Order within -1 hours and -22 minutes to receive by Fri Nov 15

Get A Quote
In stock
Order Product
MEK1001
The multiplex ELISA kits require special plate readers. For more info see special plate reader. The $800 demo option is for new customer only, see more info at demo options.
$2,805.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.