Product Info Summary
SKU: | EK1186 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Mouse |
Application: | ELISA |
Sample Types: | cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). |
Product info
Product Name
Mouse SP-D ELISA Kit PicoKine®
SKU/Catalog Number
EK1186
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Mouse SP-D ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Sftpd in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Mouse SP-D ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1186)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: CHO; Immunogen sequence: A20-F374
Sensitivity
<10 pg/ml
Assay Range
312 pg/ml - 20,000 pg/ml
Standard Dilution Instructions
See datasheet of EK1186 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK1186 is reactive to Sftpd in Mouse samples
Validated Sample Types
cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).
Application Guarantee
EK1186 is guaranteed for ELISA in Mouse by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of SP-D
Surfactant, pulmonary-associated protein D, also known as SFTPD or SP-D, is a protein which in humans is encoded by the SFTPD gene. By fluorescence in situ hybridization, the SP-D gene was localized in 10q22.2-q23.1. On the basis of homology with other collectins, potential functions for SP-D include roles in innate immunity and surfactant metabolism, SP-D is produced in the bronchiolar and terminal epithelium of human fetal lung from about 21 weeks of gestation. What's more, SP-A and SP-D act as dual-function surveillance molecules that reverse orientation and function and become initiators of host-defense reactions.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK1186-CAP | Anti-Mouse Sftpd Pre-coated 96-well strip microplate | 1 |
EK1186-ST | Mouse Sftpd Standard | 2 vials, 20 ng/tube |
EK1186-DA | Mouse Sftpd Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 312 | 625 | 1250 | 2500 | 5000 | 10000 | 20000 |
O.D. | 0.009 | 0.104 | 0.233 | 0.348 | 0.568 | 0.975 | 1.495 | 2.001 |
Data Example Images
Click image to see more details
Mouse SP-D PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect SP-D, Dilution ratio of 1:1, concentration in serum and plasma is around 1.5 ng/ml..
Some articles we found to cite concentrations of SP-D in samples: 23435873 (Pubmed IDs).
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Mouse SP-D ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 641 | 2014 | 9766 | 618 | 1957 | 9758 |
Standard deviation | 26.92 | 151.05 | 625.02 | 37.69 | 162.43 | 692.81 |
CV (%) | 4.2% | 7.5% | 6.4% | 6.1% | 8.3% | 7.1% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of SP-D in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 641 | 579 | 553 | 633 | 601 | 36.77 | 6.1% |
Sample 2 | 2014 | 2168 | 2058 | 1954 | 2048 | 78.24 | 3.8% |
Sample 3 | 9766 | 8221 | 8235 | 9714 | 8984 | 756.23 | 8.4% |
Protein Target Info & Infographic
Gene/Protein Information For Sftpd (Source: Uniprot.Org, NCBI)
Gene Name
Sftpd
Full Name
Pulmonary surfactant-associated protein D
Weight
37688 MW
Superfamily
SFTPD family
Alternative Names
Pulmonary surfactant-associated protein D;PSP-D;SP-D;Lung surfactant protein D;Sftpd;Sftp4; SFTPD COLEC7, PSP-D, SFTP4, SP-D surfactant protein D pulmonary surfactant-associated protein D|collectin-7|lung surfactant protein D|pulmonary surfactant apoprotein|surfactant-associated protein, pulmonary 4
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on Sftpd, check out the Sftpd Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for Sftpd: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Mouse SP-D ELISA Kit PicoKine® (EK1186)
Hello CJ!
No publications found for EK1186
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Mouse SP-D ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Mouse SP-D ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
12 Customer Q&As for Mouse SP-D ELISA Kit PicoKine®
Question
Q: Can SP-D ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
Verified Customer
Verified customer
Asked: 2020-05-18
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2020-05-18
Question
For Mouse SP-D PicoKine
Verified Customer
Verified customer
Asked: 2020-04-16
Answer
The recommended dilution ratio is 1:1. The concentration range of SP-D in mouse plasma is 1-10ng/ml.
Boster Scientific Support
Answered: 2020-04-16
Question
Q: how are cell lysates prepared for use in Picokine® ELISA kits?
Verified Customer
Verified customer
Asked: 2019-11-28
Answer
A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer can change immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2019-11-28
Question
Does EK1186 contain thimerosal? If so, what is the concentration?
Verified customer
Asked: 2019-10-02
Answer
No, the Mouse SP-D ELISA Kit PicoKine® (EK1186) does not contain any thimerosal.
Boster Scientific Support
Answered: 2019-10-02
Question
What is the immunized animal and purification way of antibody in the EK1186 kit?
Verified customer
Asked: 2019-10-02
Answer
For the Mouse SP-D ELISA Kit PicoKine™ (EK1186), the capture and detection antibody is polyclonal antibody from sheep.
Boster Scientific Support
Answered: 2019-10-08
Question
Q: if the enzyme conjugated SP-D antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the SP-D antigen?
S. Jha
Verified customer
Asked: 2019-01-22
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2019-01-22
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
Verified Customer
Verified customer
Asked: 2018-09-14
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions
Boster Scientific Support
Answered: 2018-09-14
Question
Q: how can I thaw whole blood sample for SP-D ELISA after freezing?
H. Jones
Verified customer
Asked: 2018-09-13
Answer
A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test SP-D for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.
Boster Scientific Support
Answered: 2018-09-13
Question
Q: is it okay to use citrate plasma as samples in Mouse SP-D Picokine® ELISA Kit (Catalog # EK1186)?
J. Roberts
Verified customer
Asked: 2018-07-30
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can attach metal ions from the functional domain of SP-D causing degradation of its protein structure. SP-D may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the SP-D ELISA, treating samples with various anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2018-07-30
Question
Q: we need your suggestion regarding the dilution ratio of serum samples for detection of SP-D in Mouse plasma? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have low serum quantitys so we like to dilute as much as possible.
C. Martin
Verified customer
Asked: 2018-05-02
Answer
A: without having an understanding the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the SP-D ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2018-05-02
Question
Q: how do I analyze ELISA data? I have obtained SP-D level in plasma.
L. Mehta
Verified customer
Asked: 2018-03-13
Answer
A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online
Boster Scientific Support
Answered: 2018-03-13
Question
Q: What is the optimal O.D. value for SP-D ELISA kit? I used your SP-D ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain SP-D even though the O.D. values are not very high?
Verified Customer
Verified customer
Asked: 2015-03-15
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in the example mentioned, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this SP-D ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of SP-D that can be declared/interpreted as positive by the above standard is 10pg/ml.
Boster Scientific Support
Answered: 2015-03-15