Mouse HAI-2/SPINT2 ELISA Kit PicoKine®

HAI-2/SPINT2 ELISA kit for Mouse

Mouse HAI-2/SPINT2 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Spint2 in cell culture supernatants, serum, plasma (heparin, EDTA) and cell lysates. Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Product Info Summary

SKU: EK0774
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, serum, plasma (heparin, EDTA) and cell lysates.

Product Name

Mouse HAI-2/SPINT2 ELISA Kit PicoKine®

View all HAI-2/SPINT2 ELISA kits

SKU/Catalog Number

EK0774

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse HAI-2/SPINT2 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Spint2 in cell culture supernatants, serum, plasma (heparin, EDTA) and cell lysates. Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse HAI-2/SPINT2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0774)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: NS0; Immunogen sequence: R30-K140

Sensitivity

<10 pg/ml

Assay Range

31.2 pg/ml - 2,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK0774 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0774 is reactive to Spint2 in Mouse samples

Validated Sample Types

cell culture supernatants, serum, plasma (heparin, EDTA) and cell lysates.

Application Guarantee

EK0774 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of HAI-2/SPINT2

Kunitz-type protease inhibitor 2 is an enzyme inhibitor that in humans is encoded by the SPINT2 gene. This gene encodes a transmembrane protein with two extracellular Kunitz domains that inhibits a variety of serine proteases. The protein inhibits HGF activator which prevents the formation of active hepatocyte growth factor. And this gene is a putative tumor suppressor, and mutations in this gene result in congenital sodium diarrhea. Multiple transcript variants encoding different isoforms have been found for this gene.

Kit Components

Catalog Number Description Quantity
EK0774-CAP Anti-Mouse Spint2 Pre-coated 96-well strip microplate 1
EK0774-ST Mouse Spint2 Standard 2 vials, 10 ng/tube
EK0774-DA Mouse Spint2 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)031.262.512525050010002000
O.D.0.0510.1510.1990.3310.5480.9321.6222.269

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect HAI-2/SPINT2, Dilution ratio of 1:1, concentration in serum and plasma is around 100 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse HAI-2/SPINT2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)6124083764248772
Standard deviation4.1413.9246.035.5617.8555.58
CV (%)6.8%5.8%5.5%8.7%7.2%7.2%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of HAI-2/SPINT2 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 161616257601.923.2%
Sample 22402432642492499.243.7%
Sample 383792184296389053.385.9%
*number of samples for each test n=16.

Gene/Protein Information For Spint2 (Source: Uniprot.Org, NCBI)

Gene Name

Spint2

Full Name

Kunitz-type protease inhibitor 2

Weight

27914 MW

Alternative Names

Kunitz-type protease inhibitor 2;Hepatocyte growth factor activator inhibitor type 2;HAI-2;Spint2;Hai2; SPINT2 DIAR3, HAI-2, HAI2, Kop, PB serine peptidase inhibitor, Kunitz type 2 kunitz-type protease inhibitor 2|hepatocyte growth factor activator inhibitor type 2|serine protease inhibitor, Kunitz type, 2|testicular tissue protein Li 183

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on Spint2, check out the Spint2 Infographic

Spint2 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for Spint2: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK0774

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Mouse HAI-2/SPINT2 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Mouse HAI-2/SPINT2 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

8 Customer Q&As for Mouse HAI-2/SPINT2 ELISA Kit PicoKine®

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2020-12-08

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2020-12-08

Question

Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for quantification HAI-2 using the EK0774 Mouse HAI-2 Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2020-09-08

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may alter the stabilityof samples. It is recommend to assay sample on-stat collection when possible, or aliquot into single use volumes and store samples frozen. avoid repeat freeze-thaw cycles with the stored samples in order to prevent protein degradation.

Boster Scientific Support

Answered: 2020-09-08

Question

Q: What is the optimal O.D. value for HAI-2 ELISA kit? I performed your HAI-2 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain HAI-2 even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2020-05-27

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. a point of focus should be is whether your sample O.D. values are statistically significantly higher than your blank values. considering your assay, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this HAI-2 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of HAI-2 that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2020-05-27

Question

Q: we need your suggestion regarding the dilution ratio of serum samples for detection of HAI-2 in Mouse cell lysates? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have low serum volumes so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2019-06-13

Answer

A: unable to understand the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the HAI-2 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2019-06-13

Question

Q: if the enzyme conjugated HAI-2 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the HAI-2 antigen?

Verified Customer

Verified customer

Asked: 2019-04-10

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2019-04-10

Question

Q: is it okay to use citrate plasma as samples in Mouse HAI-2 Picokine® ELISA Kit (Catalog # EK0774)?

E. Green

Verified customer

Asked: 2018-01-31

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can bind metal ions from the functional domain of HAI-2 causing disruption of its protein structure. HAI-2 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the HAI-2 ELISA, treating samples with a number of anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2018-01-31

Question

Q: Can HAI-2 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2017-08-02

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2017-08-02

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

C. Moore

Verified customer

Asked: 2016-02-15

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2016-02-15

$499
In stock, 1 left.

Order within 0 hours and 58 minutes to receive by Fri Nov 22

Get A Quote
In stock
Order Product
EK0774
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.