Human SPINT1/HAI-1 ELISA Kit PicoKine®

HAI-1/HGFA Inhibitor 1 ELISA kit for Human

Human SPINT1/HAI-1 ELISA Kit PicoKine® (96 Tests). Quantitate Human SPINT1 in cell culture supernatants, serum and plasma (heparin). Sensitivity: 15pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Product Info Summary

SKU: EK0771
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin).

Product Name

Human SPINT1/HAI-1 ELISA Kit PicoKine®

View all HAI-1/HGFA Inhibitor 1 ELISA kits

SKU/Catalog Number

EK0771

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human SPINT1/HAI-1 ELISA Kit PicoKine® (96 Tests). Quantitate Human SPINT1 in cell culture supernatants, serum and plasma (heparin). Sensitivity: 15pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human SPINT1/HAI-1 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0771)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: NS0; Immunogen sequence: G36-L529

Sensitivity

<15 pg/ml

Assay Range

156 pg/ml - 10,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK0771 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0771 is reactive to SPINT1 in Human samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin).

Application Guarantee

EK0771 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of HAI-1/HGFA Inhibitor 1

Kunitz-type protease inhibitor 1 is an enzyme that in humans is encoded by the SPINT1 gene. It is a member of the Kunitz family of serine protease inhibitors. The SPINT1 gene encodes an inhibitor of hepatocyte growth factor activator (HGFAC) and matriptase and is involved in degradation of the extracellular matrix. SPINT1 is produced as an active membrane-associated protein and is proteolytically cleaved and secreted. Alternative splicing results in multiple variants encoding different isoforms.

Kit Components

Catalog Number Description Quantity
EK0771-CAP Anti-Human SPINT1 Pre-coated 96-well strip microplate 1
EK0771-ST Human SPINT1 Standard 2 vials, 10 ng/tube
EK0771-DA Human SPINT1 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015631262512500025000500010000
O.D.0.0390.1190.2030.3460.6370.9451.6102.225

Data Example Images

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human SPINT1/HAI-1 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)2221803399024118733890
Standard deviation14.65108.18251.3719.03123.61303.42
CV (%)6.6%6%6.6%7.9%6.6%7.8%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of HAI-1/HGFA Inhibitor 1 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 122225121824023213.45.7%
Sample 21803170117021716173042.272.4%
Sample 339904390430246684337241.865.5%
*number of samples for each test n=16.

Gene/Protein Information For SPINT1 (Source: Uniprot.Org, NCBI)

Gene Name

SPINT1

Full Name

Kunitz-type protease inhibitor 1

Weight

58398 MW

Alternative Names

Kunitz-type protease inhibitor 1;Hepatocyte growth factor activator inhibitor type 1;HAI-1;SPINT1;HAI1;UNQ223/PRO256; SPINT1 HAI, HAI1, MANSC2 serine peptidase inhibitor, Kunitz type 1 kunitz-type protease inhibitor 1|HAI-1|hepatocyte growth factor activator inhibitor type 1|serine protease inhibitor, Kunitz type 1

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on SPINT1, check out the SPINT1 Infographic

SPINT1 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for SPINT1: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK0771

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Human SPINT1/HAI-1 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Human SPINT1/HAI-1 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

9 Customer Q&As for Human SPINT1/HAI-1 ELISA Kit PicoKine®

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2019-06-05

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2019-06-05

Question

Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for quantification HAI-1 using the EK0771 Human HAI-1 Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2019-05-29

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may affect the stabilityof samples. It is recommend to assay sample on priority basis collection when possible, or aliquot into single use volumes and store samples frozen. avoid repeat freeze-thaw cycles with the stored samples in order to prevent protein degradation.

Boster Scientific Support

Answered: 2019-05-29

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2019-03-10

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may depends upon the kit used so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2019-03-10

Question

Q: can you tell me how to prepare cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2019-01-14

Answer

A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are included in the product insert. Components in lysate and lysis buffer may impact immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2019-01-14

Question

Q: What is the optimal O.D. value for HAI-1 ELISA kit? I performed your HAI-1 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain HAI-1 even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2018-11-20

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. what you should focus on is whether your sample O.D. values are statistically significantly higher than your blank values. regarding your protocol, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this HAI-1 ELISA kit to have sensitivity of 15pg/ml, that means the minimum amount of HAI-1 that can be declared/interpreted as positive by the above standard is 15pg/ml.

Boster Scientific Support

Answered: 2018-11-20

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

B. Young

Verified customer

Asked: 2018-07-10

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2018-07-10

Question

Q: is it okay to use citrate plasma as samples in Human HAI-1 Picokine® ELISA Kit (Catalog # EK0771)?

Verified Customer

Verified customer

Asked: 2016-03-30

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can irreversibly bind metal ions from the functional domain of HAI-1 causing degradation of its protein structure. HAI-1 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes needed for detection and block the antigen antibody reaction. We have tested the HAI-1 ELISA, treating samples with a number of anticoagulants and decided that heparin can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2016-03-30

Question

Q: how to thaw whole blood sample for HAI-1 ELISA after freezing?

W. Brown

Verified customer

Asked: 2015-12-21

Answer

A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test HAI-1 for a later time, you should let the blood clot in glass tubes and collect the serum to freeze for later use.

Boster Scientific Support

Answered: 2015-12-21

Question

Q: if the enzyme conjugated HAI-1 antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the HAI-1 antigen?

B. Jha

Verified customer

Asked: 2014-01-07

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2014-01-07

$499
Backordered.

Lead time for this item is typically 2-3 weeks

Get A Quote
In stock
Order Product
EK0771
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.