Human Serpin G1 ELISA Kit PicoKine®

Serpin G1/C1 Inhibitor ELISA kit for Human

Human Serpin G1 ELISA Kit PicoKine™ (96 Tests). Quantitate Human SERPING1 in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml.

Product Info Summary

SKU: EK1667
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin, EDTA).

Product Name

Human Serpin G1 ELISA Kit PicoKine®

View all Serpin G1/C1 Inhibitor ELISA kits

SKU/Catalog Number

EK1667

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human Serpin G1 ELISA Kit PicoKine™ (96 Tests). Quantitate Human SERPING1 in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human Serpin G1 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1667)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: N23-A500

Sensitivity

<10 pg/ml

Assay Range

156 pg/ml - 10,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1667 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1667 is reactive to SERPING1 in Human samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin, EDTA).

Application Guarantee

EK1667 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of Serpin G1/C1 Inhibitor

This gene encodes a highly glycosylated plasma protein involved in the regulation of the complement cascade. Its protein inhibits activated C1r and C1s of the first complement component and thus regulates complement activation. Deficiency of this protein is associated with hereditary angioneurotic oedema (HANE). Alternative splicing results in multiple transcript variants encoding the same isoform.

Kit Components

Catalog Number Description Quantity
EK1667-CAP Anti-Human SERPING1 Pre-coated 96-well strip microplate 1
EK1667-ST Human SERPING1 Standard 2 vials, 10 ng/tube
EK1667-DA Human SERPING1 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015631262512502500500010000
O.D.0.1080.2140.3460.5530.8291.1531.6572.012

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect Serpin G1/C1 Inhibitor, Dilution ratio of 1:100000, concentration in serum and plasma is 180-248 ug/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human Serpin G1 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)22212976024224214186290
Standard deviation13.9863.55365.718.3995377.4
CV (%)6.7%4.9%6%7.6%6.7%6%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of Serpin G1/C1 Inhibitor in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 122225120921822515.736.9%
Sample 21297124912151306126636.92.9%
Sample 360956211606154145945311.715.2%
*number of samples for each test n=16.

Gene/Protein Information For SERPING1 (Source: Uniprot.Org, NCBI)

Gene Name

SERPING1

Full Name

Plasma protease C1 inhibitor

Weight

Superfamily

serpin family

Alternative Names

C1 Inhibitor; C1IN; C1INH; C1NH; HAE1; HAE2; Serpin G1; SERPING1 serpin peptidase inhibitor, clade G (C1 inhibitor), member 1 SERPING1 C1IN, C1INH, C1NH, HAE1, HAE2 serpin family G member 1 plasma protease C1 inhibitor|C1 esterase inhibitor|C1-inhibiting factor|C1-inhibitor|complement component 1 inhibitor|epididymis secretory sperm binding protein|serine/cysteine proteinase inhibitor clade G member 1|serpin G1|serpin peptidase inhibitor clade G member 1|serpin peptidase inhibitor, clade G (C1 inhibitor), member 1

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on SERPING1, check out the SERPING1 Infographic

SERPING1 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for SERPING1: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK1667

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Human Serpin G1 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Human Serpin G1 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

8 Customer Q&As for Human Serpin G1 ELISA Kit PicoKine®

Question

Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2020-08-17

Answer

A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer may affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2020-08-17

Question

Q: if the enzyme conjugated Serpin G1 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the Serpin G1 antigen?

J. Yang

Verified customer

Asked: 2020-08-03

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2020-08-03

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2020-07-05

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is a must for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2020-07-05

Question

Q: What is the optimal O.D. value for Serpin G1 ELISA kit? I performed your Serpin G1 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain Serpin G1 even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2019-01-14

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. what you should focus on is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this Serpin G1 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of Serpin G1 that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2019-01-14

Question

Q: can you suggest the dilution ratio of serum samples for detection of Serpin G1 in Human serum? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have limited sample volumes so we like to dilute as much as possible.

Verified Customer

Verified customer

Asked: 2018-10-30

Answer

A: without having an understanding the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the Serpin G1 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2018-10-30

Question

Q: how much samples can be assayed in a Picokine® ELISA Kit?

M. Singh

Verified customer

Asked: 2018-04-03

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2018-04-03

Question

Q: how do I analyze ELISA data? I have performed Serpin G1 level in serum.

Verified Customer

Verified customer

Asked: 2018-03-03

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2018-03-03

Question

Q: how long can samples (cell cultures, serum, and plasma) be stored and still be stable for measuring Serpin G1 using the EK1667 Human Serpin G1 Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2018-02-28

Answer

A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample on priority basis collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples to limit protein degradation.

Boster Scientific Support

Answered: 2018-02-28

$499
In stock, 3+ left.

Order within 2 hours and 57 minutes to receive by Mon Jul 1

Get A Quote
In stock
Order Product
EK1667
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.