Human Relaxin-3/RLN3 ELISA Kit PicoKine®

Relaxin-3 ELISA kit for Human

Human Relaxin 3 ELISA Kit PicoKine® (96 Tests). Quantitate Human RLN3 in cell culture supernatants, serum and plasma ( heparin). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Product Info Summary

SKU: EK1407
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma ( heparin).

Product Name

Human Relaxin-3/RLN3 ELISA Kit PicoKine®

View all Relaxin-3 ELISA kits

SKU/Catalog Number

EK1407

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human Relaxin 3 ELISA Kit PicoKine® (96 Tests). Quantitate Human RLN3 in cell culture supernatants, serum and plasma ( heparin). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human Relaxin-3/RLN3 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1407)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: E.coli; Immunogen sequence: D119-C142 (A) & A27-R53 (B)

Sensitivity

<10 pg/ml

Assay Range

31.2 pg/ml - 2,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK1407 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1407 is reactive to RLN3 in Human samples

Validated Sample Types

cell culture supernatants, serum and plasma ( heparin).

Application Guarantee

EK1407 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of Relaxin-3

Relaxin-3 is a neuropeptide which is highly conserved in species ranging from flies, fish, rodents and humans. It is a member and ancestral gene of the relaxin family of peptides, which includes the namesake hormone relaxin (designated 'H2 relaxin' in humans) which mediates peripheral actions during pregnancy and which was found to relax the pelvic ligament in guinea pigs almost a century ago. The broad distribution of relaxin-3 fibres/RXFP3 within several key neuronal circuits suggests an ability to modulate a broad range of behaviours. This has been confirmed in a growing number of rodent studies, which demonstrate relaxin-3 is able to modulate arousal, the response to stress, feeding/metabolism and memory; and likely plays a role in the generation/regulation of hippocampal theta rhythm.

Kit Components

Catalog Number Description Quantity
EK1407-CAP Anti-Human RLN3 Pre-coated 96-well strip microplate 1
EK1407-ST Human RLN3 Standard 2 vials, 10 ng/tube
EK1407-DA Human RLN3 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)031.262.512525050010002000
O.D.0.0200.0690.1140.2280.4430.7831.3952.022

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect Relaxin-3, Dilution ratio of 1:1, concentration in serum and plasma is less than the lowest standard, 31.2 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human Relaxin-3/RLN3 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)6522594260227930
Standard deviation4.4215.0763.117.7%18.3871.61
CV (%)6.8%6.7%6.7%8.5%8.1%7.7%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of Relaxin-3 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 165666670661.922.9%
Sample 22252192092352229.434.2%
Sample 39421017854103096070.197.3%
*number of samples for each test n=16.

Gene/Protein Information For RLN3 (Source: Uniprot.Org, NCBI)

Gene Name

RLN3

Full Name

Relaxin-3

Weight

15451 MW

Superfamily

insulin family

Alternative Names

Relaxin-3;Insulin-like peptide INSL7;Insulin-like peptide 7;Prorelaxin H3;Relaxin-3 B chain;Relaxin-3 A chain;RLN3;INSL7, RXN3, ZINS4;UNQ6188/PRO20213; RLN3 H3, RXN3, ZINS4, insl7 relaxin 3 relaxin-3|insulin-like peptide 7|insulin-like peptide INSL7|prorelaxin H3

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on RLN3, check out the RLN3 Infographic

RLN3 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for RLN3: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK1407

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Human Relaxin-3/RLN3 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Human Relaxin-3/RLN3 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

9 Customer Q&As for Human Relaxin-3/RLN3 ELISA Kit PicoKine®

Question

Q: Can Relaxin-3 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

T. Johnson

Verified customer

Asked: 2020-07-25

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is needed. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2020-07-25

Question

Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2020-04-19

Answer

A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are included in the product insert. Components in lysate and lysis buffer can affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2020-04-19

Question

Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for measurement Relaxin-3 using the EK1407 Human Relaxin-3 Picokine® ELISA Kit?

C. Turner

Verified customer

Asked: 2020-03-31

Answer

A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may affect the stabilityof samples. It is recommend to assay sample immediately after collection when possible, or aliquot into single use volumes and store samples frozen. avoid repetitive freeze-thaw cycles with the stored samples to avoid protein degradation.

Boster Scientific Support

Answered: 2020-03-31

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2020-03-23

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2020-03-23

Question

Q: how to proceed with the analysis of ELISA data? I measured Relaxin-3 level in plasma.

Verified Customer

Verified customer

Asked: 2019-11-15

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2019-11-15

Question

Was cross-reactivity assessed with HPLC for EK1407? If not, how as it tested?

Verified customer

Asked: 2019-04-11

Answer

For Human Relaxin 3 ELISA Kit PicoKine™ (EK1407), our lab did not assess cross-reactivity with HPLC. They tested recombinant human Relaxin-1 and Relaxin-2 proteins and did not observe any significant cross-reactivity.

Boster Scientific Support

Answered: 2019-04-12

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

W. Martinez

Verified customer

Asked: 2018-12-20

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2018-12-20

Question

Q: What is the optimal O.D. value for Relaxin-3 ELISA kit? I performed your Relaxin-3 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain Relaxin-3 even though the O.D. values are not very high?

Verified Customer

Verified customer

Asked: 2018-08-08

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. what you should focus on is whether your sample O.D. values are statistically significantly higher than your blank values. regarding your assay, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this Relaxin-3 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of Relaxin-3 that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2018-08-08

Question

Q: we need your suggestion regarding the dilution ratio of serum samples for detection of Relaxin-3 in Human plasma? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have limited sample quantitys so we like to dilute as much as possible.

W. Adams

Verified customer

Asked: 2018-06-07

Answer

A: unable to understand the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the Relaxin-3 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2018-06-07

$750
In stock, 3+ left.

Order within 87 hours and 44 minutes to receive by Tue Nov 19

Get A Quote
In stock
Order Product
EK1407
$750.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.