Human MBL2/MPB-C ELISA Kit PicoKine®

MBL2 ELISA kit for Human

Human MBL2/MPB-C ELISA Kit PicoKine® (96 Tests). Quantitate Human MBL2 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays. Cited in 1 publication(s).

Product Info Summary

SKU: EK0805
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Human MBL2/MPB-C ELISA Kit PicoKine®

View all MBL2 ELISA kits

SKU/Catalog Number

EK0805

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human MBL2/MPB-C ELISA Kit PicoKine® (96 Tests). Quantitate Human MBL2 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human MBL2/MPB-C ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0805)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: NS0; Immunogen sequence: E21-I248

Sensitivity

<10 pg/ml

Assay Range

312 pg/ml - 20,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK0805 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK0805 is reactive to MBL2 in Human samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK0805 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of MBL2

MBL2, also called mannose-binding lectin (protein C) 2, soluble or Mannose-binding lectin (MBL) is a lectin that is instrumental in innate immunity. MBL2 is mapped to chromosome 10q11.2-q21. It belongs to the class of collectins in the C-type lectin superfamily, whose function appears to be pattern recognition in the first line of defense in the pre-immune host. MBL2 recognizes carbohydrate patterns, found on the surface of a large number of pathogenic micro-organisms, including bacteria, viruses, protozoa and fungi. Binding MBL2 to a micro-organism results in activation of the lectin pathway of the complement system. Another important function of MBL2 is that this molecule binds senescent and apoptotic cells and enhances engulfment of whole, intact apoptotic cells, as well as cell debris by phagocytes.

Kit Components

Catalog Number Description Quantity
EK0805-CAP Anti-Human MBL2 Pre-coated 96-well strip microplate 1
EK0805-ST Human MBL2 Standard 2 vials, 20 ng/tube
EK0805-DA Human MBL2 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)03126251250250050001000020000
O.D.0.0060.1580.3060.5380.8071.2611.6471.940

Data Example Images

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human MBL2/MPB-C ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)4792854870245827858839
Standard deviation27.3129.09661.3534.35147.6742.47
CV (%)5.7%4.4%7.6%7.5%5.3%8.4%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of MBL2 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 147954647547549330.216.1%
Sample 22934291029382814289950.221.7%
Sample 387029816852793849107519.575.7%
*number of samples for each test n=16.

Gene/Protein Information For MBL2 (Source: Uniprot.Org, NCBI)

Gene Name

MBL2

Full Name

Mannose-binding protein C

Weight

26144 MW

Alternative Names

Mannose-binding protein C;MBP-C;Collectin-1;MBP1;Mannan-binding protein;Mannose-binding lectin;MBL2;COLEC1, MBL; MBL2 COLEC1, HSMBPC, MBLD, MBP, MBP-C, MBP1, MBPD, MBL2 mannose binding lectin 2 mannose-binding protein C|collectin-1|mannan-binding lectin|mannose-binding lectin (protein C) 2, soluble (opsonic defect)|mannose-binding lectin 2, soluble (opsonic defect)

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on MBL2, check out the MBL2 Infographic

MBL2 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for MBL2: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK0805 has been cited in 1 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

Gomaa MH, Ali SS, Fattouh AM, Hamza HS, Badr MM. Pediatr Rheumatol Online J. 2018 Apr 13;16(1):24. doi: 10.1186/s12969-018-0245-x. MBL2 gene polymorphism rs1800450 and rheumatic fever with and without rheumatic heart disease: an Egyptian pilot study

Have you used Human MBL2/MPB-C ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Human MBL2/MPB-C ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

9 Customer Q&As for Human MBL2/MPB-C ELISA Kit PicoKine®

Question

Does EK0805 contain sodium azide?

Verified customer

Asked: 2020-12-30

Answer

Our EK products like the Human MBL2/MPB-C ELISA Kit PicoKine™ (EK0805) do not contain sodium azide.

Boster Scientific Support

Answered: 2021-01-04

Question

Q: if the enzyme conjugated MBL2 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the MBL2 antigen?

Verified Customer

Verified customer

Asked: 2020-11-04

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2020-11-04

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2020-01-18

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2020-01-18

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2018-11-19

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2018-11-19

Question

Q: which procedure should I follow in order to thaw whole blood sample for MBL2 ELISA after freezing?

Verified Customer

Verified customer

Asked: 2018-08-14

Answer

A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test MBL2 for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.

Boster Scientific Support

Answered: 2018-08-14

Question

Q: Can MBL2 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2018-07-04

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2018-07-04

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2018-06-29

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2018-06-29

Question

Q: we need your recommendation regarding the dilution ratio of serum samples for detection of MBL2 in Human serum? I am trying to measure a few analytes and it requires 100ul of diluted samples for each well. We have low serum volumes so we like to dilute as much as possible.

B. Taylor

Verified customer

Asked: 2017-09-14

Answer

A: unable to know the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the MBL2 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.

Boster Scientific Support

Answered: 2017-09-14

Question

Q: how do I analyze ELISA data? I have performed MBL2 level in serum.

Verified Customer

Verified customer

Asked: 2016-10-29

Answer

A: we recommend you this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2016-10-29

$499
In stock, 3+ left.

Order within 51 hours and 40 minutes to receive by Tue Nov 26

Get A Quote
In stock
Order Product
EK0805
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.

No publications found

No publications have been found for this product