Product Info Summary
SKU: | EK1844 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Human |
Application: | ELISA |
Sample Types: | cell culture supernatants, serum and plasma (heparin, EDTA). |
Product info
Product Name
Human JAM-C ELISA Kit PicoKine®
SKU/Catalog Number
EK1844
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human JAM-C ELISA Kit PicoKine® (96 Tests). Quantitate Human JAM3 in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human JAM-C ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1844)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: V32-N241
Sensitivity
<10 pg/ml
Assay Range
46.9 pg/ml - 3,000 pg/ml
Standard Dilution Instructions
See datasheet of EK1844 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK1844 is reactive to JAM3 in Human samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin, EDTA).
Application Guarantee
EK1844 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of JAM-C
This gene is mapped to 11q25. Tight junctions represent one mode of cell-to-cell adhesion in epithelial or endothelial cell sheets, forming continuous seals around cells and serving as a physical barrier to prevent solutes and water from passing freely through the paracellular space. The protein encoded by this immunoglobulin superfamily gene member is localized in the tight junctions between high endothelial cells. Unlike other proteins in this family, the this protein is unable to adhere to leukocyte cell lines and only forms weak homotypic interactions. The encoded protein is a member of the junctional adhesion molecule protein family and acts as a receptor for another member of this family. A mutation in an intron of this gene is associated with hemorrhagic destruction of the brain, subependymal calcification, and congenital cataracts. Alternative splicing results in multiple transcript variants.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK1844-CAP | Anti-Human JAM3 Pre-coated 96-well strip microplate | 1 |
EK1844-ST | Human JAM3 Standard | 2 vials, 10 ng/tube |
EK1844-DA | Human JAM3 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 46.9 | 93.8 | 187.5 | 375 | 750 | 1500 | 3000 |
O.D. | 0.026 | 0.075 | 0.153 | 0.204 | 0.429 | 0.767 | 1.389 | 1.992 |
Data Example Images
Click image to see more details
Human JAM-C PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect JAM-C, Dilution ratio of 1:1, concentration in serum and plasma is around 300 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human JAM-C ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 90 | 422 | 1408 | 92 | 430 | 1466 |
Standard deviation | 4.86 | 23.63 | 57.73 | 4.32 | 27.09 | 104.09 |
CV (%) | 5.4% | 5.6% | 4.1% | 4.7% | 6.3% | 7.1% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of JAM-C in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 90 | 96 | 100 | 99 | 96 | 3.89 | 4.0% |
Sample 2 | 422 | 347 | 363 | 385 | 379 | 28.12 | 7.4% |
Sample 3 | 1408 | 1509 | 1433 | 1363 | 1428 | 52.94 | 3.7% |
Protein Target Info & Infographic
Gene/Protein Information For JAM3 (Source: Uniprot.Org, NCBI)
Gene Name
JAM3
Full Name
Junctional adhesion molecule C
Weight
35.02kDa
Superfamily
immunoglobulin superfamily
Alternative Names
Junctional adhesion molecule C; JAM-C; JAM-2; Junctional adhesion molecule 3; JAM-3; Jam3; UNQ859/PRO1868 JAM3 JAM-2, JAM-3, JAM-C, JAMC junctional adhesion molecule 3 junctional adhesion molecule C
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on JAM3, check out the JAM3 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for JAM3: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Human JAM-C ELISA Kit PicoKine® (EK1844)
Hello CJ!
No publications found for EK1844
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Human JAM-C ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Human JAM-C ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
7 Customer Q&As for Human JAM-C ELISA Kit PicoKine®
Question
Q: What is the optimal O.D. value for JAM-C ELISA kit? I performed your JAM-C ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain JAM-C even though the O.D. values are not very high?
Verified Customer
Verified customer
Asked: 2020-09-24
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this JAM-C ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of JAM-C that can be declared/interpreted as positive by the above standard is 10pg/ml.
Boster Scientific Support
Answered: 2020-09-24
Question
Q: if the enzyme conjugated JAM-C antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the JAM-C antigen?
H. Bhatt
Verified customer
Asked: 2020-05-31
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2020-05-31
Question
Q: Can JAM-C ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
Verified Customer
Verified customer
Asked: 2020-05-03
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is needed. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2020-05-03
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
Verified Customer
Verified customer
Asked: 2019-04-09
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2019-04-09
Question
Q: how can I thaw whole blood sample for JAM-C ELISA after freezing?
Verified Customer
Verified customer
Asked: 2018-09-28
Answer
A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test JAM-C for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.
Boster Scientific Support
Answered: 2018-09-28
Question
Q: can I use citrate plasma as samples in Human JAM-C Picokine® ELISA Kit (Catalog # EK1844)?
T. Kaur
Verified customer
Asked: 2018-09-14
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can irreversibly bind metal ions from the functional domain of JAM-C causing degradation of its protein structure. JAM-C may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes required for detection and block the antigen antibody reaction. We have tested the JAM-C ELISA, treating samples with a number of anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2018-09-14
Question
Q: can you tell me how to prepare cell lysates prepared for use in Picokine® ELISA kits?
Verified Customer
Verified customer
Asked: 2018-06-20
Answer
A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are included in the product insert. Components in lysate and lysis buffer can change immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2018-06-20