Product Info Summary
SKU: | EK0728 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Human |
Application: | ELISA |
Sample Types: | cell culture supernatants, serum and plasma (heparin, EDTA, citrate). |
Product info
Product Name
Human CXCL5/LIX/ENA-78 ELISA Kit PicoKine®
SKU/Catalog Number
EK0728
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human CXCL5/LIX/ENA-78 ELISA Kit PicoKine® (96 Tests). Quantitate Human CXCL5 in cell culture supernatants, serum and plasma (heparin, EDTA, citrate). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human CXCL5/LIX/ENA-78 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0728)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: E.coli; Immunogen sequence: A37-N114
Sensitivity
<10 pg/ml
Assay Range
31.2 pg/ml - 2,000 pg/ml
Standard Dilution Instructions
See datasheet of EK0728 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0728 is reactive to CXCL5 in Human samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin, EDTA, citrate).
Application Guarantee
EK0728 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of CXCL5
C-X-C motif chemokine 5 is a protein that in humans encoded by the CXCL5 gene. The protein encoded by this gene, CXCL5 is a small cytokine belonging to the CXC chemokine family that is also known as epithelial-derived neutrophil-activating peptide 78 (ENA-78). It is produced following stimulation of cells with the inflammatory cytokines interleukin-1or tumor necrosis factor-alpha. Expression of CXCL5 has also been observed in eosinophils, and can be inhibited with the type II interferon IFN-gamma. This chemokine stimulates the chemotaxis of neutrophils possessing angiogenic properties. It elicits these effects by interacting with the cell surface chemokine receptor CXCR2. The gene for CXCL5 is encoded on four exons and is located on humanchromosome 4 amongst several other CXC chemokine genes. CXCL5 has been implicated in connective tissue remodeling. CXCL5 plays a role in reducing sensitivity to sunburn pain in some subjects, and is a potential target which can be utilized to understand more about pain in other inflammatory conditions like arthritis and cystitis.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK0728-CAP | Anti-Human CXCL5 Pre-coated 96-well strip microplate | 1 |
EK0728-ST | Human CXCL5 Standard | 2 vials, 10 ng/tube |
EK0728-DA | Human CXCL5 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 31.2 | 62.5 | 125 | 250 | 500 | 1000 | 2000 |
O.D. | 0.075 | 0.157 | 0.253 | 0.423 | 0.764 | 1.199 | 1.728 | 2.080 |
Data Example Images
Click image to see more details
Human CXCL5/ENA-78 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect CXCL5, For serum, dilution ratio is 1:1 and concentration is 442-3544 pg/ml.
For plasma, dilution ratio is 1:1 and concentration is 0-1082 pg/ml..
Some articles we found to cite concentrations of CXCL5 in samples: 8083342, 15837658 (Pubmed IDs).
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human CXCL5/LIX/ENA-78 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 66 | 270 | 964 | 61 | 293 | 970 |
Standard deviation | 2.77 | 18.09 | 74.22 | 3.53 | 22.26 | 82.45 |
CV (%) | 4.2% | 6.7% | 7.7% | 5.8% | 7.6% | 8.5% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of CXCL5 in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 66 | 77 | 65 | 68 | 69 | 4.74 | 6.8% |
Sample 2 | 270 | 257 | 287 | 288 | 275 | 12.85 | 4.6% |
Sample 3 | 964 | 912 | 900 | 813 | 897 | 54.26 | 6% |
Protein Target Info & Infographic
Gene/Protein Information For CXCL5 (Source: Uniprot.Org, NCBI)
Gene Name
CXCL5
Full Name
C-X-C motif chemokine 5
Weight
11972 MW
Superfamily
intercrine alpha (chemokine CxC) family
Alternative Names
C-X-C motif chemokine 5;ENA-78 (1-78);Epithelial-derived neutrophil-activating protein 78;Neutrophil-activating peptide ENA-78;Small-inducible cytokine B5;ENA-78 (8-78);ENA-78 (9-78);CXCL5;ENA78, SCYB5; CXCL5 ENA-78, SCYB5 C-X-C motif chemokine ligand 5 C-X-C motif chemokine 5|chemokine (C-X-C motif) ligand 5|epithelial-derived neutrophil-activating protein 78|neutrophil-activating peptide ENA-78|neutrophil-activating protein 78|small inducible cytokine subfamily B (Cys-X-Cys), member 5 (epithelial-derived neutrophil-activating peptide 78)
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on CXCL5, check out the CXCL5 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for CXCL5: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Human CXCL5/LIX/ENA-78 ELISA Kit PicoKine® (EK0728)
Hello CJ!
EK0728 has been cited in 3 publications:
*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.
High C-X-C motif chemokine 5 expression is associated with malignant phenotypes of prostate cancer cells via autocrine and paracrine pathways
High C-X-C motif chemokine 5 expression is associated with malignant phenotypes of prostate cancer cells via autocrine and paracrine pathways
Yang Y, Hou J, Shao M, Zhang W, Qi Y, E S, Wang S, Sui H, Meng D, Wang B, Wang M, Han Y, Cao Y, Huang X, Li Y, Zhang P, Wang W. Oncol Lett. 2017 Dec;14(6):7977-7985. doi: 10.3892/ol.2017.7236. Epub 2017 Oct 20. CXCL5 as an autocrine or paracrine c...
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Human CXCL5/LIX/ENA-78 ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Human CXCL5/LIX/ENA-78 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
7 Customer Q&As for Human CXCL5/LIX/ENA-78 ELISA Kit PicoKine®
Question
Q: how are cell lysates prepared for use in Picokine® ELISA kits?
Verified Customer
Verified customer
Asked: 2020-08-03
Answer
A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate can be found in the product insert. Components in lysate and lysis buffer can have an affect on immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2020-08-03
Question
Q: can you recommend the dilution ratio of serum samples for detection of CXCL5 in Human plasma? I am trying to measure a a number of analytes and it requires 100ul of diluted samples for each well. We have limited sample quantitys so we like to dilute as much as possible.
Verified Customer
Verified customer
Asked: 2020-07-30
Answer
A: without knowing the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CXCL5 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2020-07-30
Question
Q: how to thaw whole blood sample for CXCL5 ELISA after freezing?
Verified Customer
Verified customer
Asked: 2020-04-26
Answer
A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test CXCL5 for a later time, you should let the blood clot in glass tubes and separate the serum to freeze for later analysis.
Boster Scientific Support
Answered: 2020-04-26
Question
Q: is it okay to use EDTA plasma as samples in Human CXCL5 Picokine® ELISA Kit (Catalog # EK0728)?
H. Gonzalez
Verified customer
Asked: 2020-03-22
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can irreversibly bind metal ions from the functional domain of CXCL5 causing disruption of its protein structure. CXCL5 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes required for detection and block the antigen antibody reaction. We have tested the CXCL5 ELISA, treating samples with different anticoagulants and decided that heparin, EDTA or citrate can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2020-03-22
Question
Q: What is the optimal O.D. value for CXCL5 ELISA kit? I performed your CXCL5 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain CXCL5 even though the O.D. values are not very high?
Verified Customer
Verified customer
Asked: 2019-04-10
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. a point of focus should be is whether your sample O.D. values are statistically significantly higher than your blank values. in the above example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this CXCL5 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of CXCL5 that can be declared/interpreted as positive by the above standard is 10pg/ml.
Boster Scientific Support
Answered: 2019-04-10
Question
Q: Are Boster Bio recombinant proteins and antibodies sterile?
W. Huang
Verified customer
Asked: 2018-08-11
Answer
A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is needed for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.
Boster Scientific Support
Answered: 2018-08-11
Question
Q: how to proceed with the analysis of ELISA data? I have performed CXCL5 level in plasma.
Verified Customer
Verified customer
Asked: 2018-04-03
Answer
A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online
Boster Scientific Support
Answered: 2018-04-03