Mouse ENTPD2 ELISA Kit PicoKine®

CD39L1/ENTPD2 ELISA kit for Mouse

Mouse ENTPD2 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Entpd2 in cell culture supernatants, serum and plasma (heparin, EDTA, citrate). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Product Info Summary

SKU: EK2014
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, serum and plasma (heparin, EDTA, citrate).

Product Name

Mouse ENTPD2 ELISA Kit PicoKine®

View all CD39L1/ENTPD2 ELISA kits

SKU/Catalog Number

EK2014

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse ENTPD2 ELISA Kit PicoKine® (96 Tests). Quantitate Mouse Entpd2 in cell culture supernatants, serum and plasma (heparin, EDTA, citrate). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse ENTPD2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK2014)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: NS0; Immunogen sequence: C26-S462

Sensitivity

<10 pg/ml

Assay Range

15.6 pg/ml - 1,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK2014 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK2014 is reactive to Entpd2 in Mouse samples

Validated Sample Types

cell culture supernatants, serum and plasma (heparin, EDTA, citrate).

Application Guarantee

EK2014 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of CD39L1/ENTPD2

Ectonucleoside triphosphate diphosphohydrolase 2 is an enzyme that in humans is encoded by the ENTPD2 gene. This gene is mapped to 2; 2 A3. The protein encoded by this gene is the type 2 enzyme of the ecto-nucleoside triphosphate diphosphohydrolase family (E-NTPDase). E-NTPDases are a family of ecto-nucleosidases that hydrolyze 5'-triphosphates. This ecto-ATPase is an integral membrane protein. Alternative splicing of this gene results in multiple transcript variants. It has been shown, by scientists from the University of Warwick, that E-NTPDase2 stimulates the growth of the eye: by testing the enzyme on tadpoles, the tadpoles were found to develop extra eyes on their body.

Kit Components

Catalog Number Description Quantity
EK2014-CAP Anti-Mouse Entpd2 Pre-coated 96-well strip microplate 1
EK2014-ST Mouse Entpd2 Standard 2 vials, 10 ng/tube
EK2014-DA Mouse Entpd2 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015.631.262.51252505001000
O.D.0.0360.0680.1260.2070.3440.5881.0471.942

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect CD39L1/ENTPD2, Dilution ratio of 1:1, concentration in serum and plasma is less than the lowest standard, 15.6 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse ENTPD2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)229141228113431
Standard deviation1.064.7322.251.436.2225.86
CV (%)4.8%5.2%5.4%5.1%5.5%6.0%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of CD39L1/ENTPD2 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 122232223220.502.2%
Sample 2911049596964.714.9%
Sample 341247745645144923.485.2%
*number of samples for each test n=16.

Gene/Protein Information For Entpd2 (Source: Uniprot.Org, NCBI)

Gene Name

Entpd2

Full Name

Ectonucleoside triphosphate diphosphohydrolase 2

Weight

53.665kDa

Superfamily

GDA1/CD39 NTPase family

Alternative Names

Ectonucleoside triphosphate diphosphohydrolase 2; NTPDase 2; CD39 antigen-like 1; Ecto-ATP diphosphohydrolase 2; Ecto-ATPDase 2; Ecto-ATPase 2; Entpd2; Cd39l1 ENTPD2 CD39L1, NTPDase-2 ectonucleoside triphosphate diphosphohydrolase 2 ectonucleoside triphosphate diphosphohydrolase 2|CD39 -like 1|NTPDase 2|ecto-ATP diphosphohydrolase 2|ecto-ATPDase 2|ecto-ATPase 2

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on Entpd2, check out the Entpd2 Infographic

Entpd2 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for Entpd2: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK2014

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Mouse ENTPD2 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Mouse ENTPD2 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

7 Customer Q&As for Mouse ENTPD2 ELISA Kit PicoKine®

Question

Q: Can CD39L1 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2020-09-13

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not valid for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2020-09-13

Question

Q: how can I thaw whole blood sample for CD39L1 ELISA after freezing?

Verified Customer

Verified customer

Asked: 2020-03-19

Answer

A: we do not recommend freezing and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test CD39L1 for a later time, you should let the blood clot in glass tubes and collect the serum to freeze for later use.

Boster Scientific Support

Answered: 2020-03-19

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Verified Customer

Verified customer

Asked: 2019-09-19

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2019-09-19

Question

Q: What is the optimal O.D. value for CD39L1 ELISA kit? I performed your CD39L1 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain CD39L1 even though the O.D. values are not very high?

V. Chen

Verified customer

Asked: 2019-08-16

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. what you should focus on is whether your sample O.D. values are statistically significantly higher than your blank values. regarding your protocol, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this CD39L1 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of CD39L1 that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2019-08-16

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2019-05-15

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may depends upon the kit used so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2019-05-15

Question

Q: how to proceed with the analysis of ELISA data? I measured CD39L1 level in serum.

Verified Customer

Verified customer

Asked: 2019-04-15

Answer

A: we recommend you this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2019-04-15

Question

Q: is it okay to use citrate plasma as samples in Mouse CD39L1 Picokine® ELISA Kit (Catalog # EK2014)?

Verified Customer

Verified customer

Asked: 2018-05-15

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can irreversibly bind metal ions from the functional domain of CD39L1 causing disruption of its protein structure. CD39L1 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes needed for detection and block the antigen antibody reaction. We have tested the CD39L1 ELISA, treating samples with various anticoagulants and decided that heparin, EDTA or citrate can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2018-05-15

$750
In stock, 2 left.

Order within 77 hours and 52 minutes to receive by Tue Nov 26

Get A Quote
In stock
Order Product
EK2014
$750.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.