Mouse CXCL3 / GRO gamma ELISA Kit PicoKine®

CXCL3/GRO gamma/CINC-2/DCIP-1 ELISA kit for Mouse

Mouse CXCL3 / GRO gamma ELISA Kit PicoKine® (96 Tests). Quantitate Mouse CXCL3 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays. Cited in 4 publication(s).

Product Info Summary

SKU: EK1364
Size: 96 wells/kit, with removable strips.
Reactive Species: Mouse
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Mouse CXCL3 / GRO gamma ELISA Kit PicoKine®

View all CXCL3/GRO gamma/CINC-2/DCIP-1 ELISA kits

SKU/Catalog Number

EK1364

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Mouse CXCL3 / GRO gamma ELISA Kit PicoKine® (96 Tests). Quantitate Mouse CXCL3 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Mouse CXCL3 / GRO gamma ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1364)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: E.coli; Immunogen sequence: S32-S100

Sensitivity

<10 pg/ml

Assay Range

15.6 pg/ml - 1,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK1364 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1364 is reactive to CXCL3 in Mouse samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK1364 is guaranteed for ELISA in Mouse by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of CXCL3/GRO gamma/CINC-2/DCIP-1

Chemokine (C-X-C motif) ligand 3 (CXCL3) is a small cytokine belonging to the CXC chemokine family. It is mapped to 14p2 in rat. CXCL3 controls migration and adhesion of monocytes and mediates its effects on its target cell by interacting with a cell surface chemokine receptor. It has been shown that CXCL3 regulates cell autonomously the migration of the precursors of cerebellar granule neurons toward the internal layers of cerebellum, during the morphogenesis of cerebellum. CXCL3 also play fundamental roles in the development, homeostasis and it has effects on cells of the central nervous system as well as on endothelial cells involved in angiogenesis or angiostasis.

Kit Components

Catalog Number Description Quantity
EK1364-CAP Anti-Mouse CXCL3 Pre-coated 96-well strip microplate 1
EK1364-ST Mouse CXCL3 Standard 2 vials, 10 ng/tube
EK1364-DA Mouse CXCL3 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015.631.262.51252505001000
O.D.0.0410.0820.1330.1870.3470.5391.1421.848

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect CXCL3/GRO gamma/CINC-2/DCIP-1, Dilution ratio of 1:1, concentration in serum and plasma is around 150 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Mouse CXCL3 / GRO gamma ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)3520551235202512
Standard deviation1.618.8121.021.7112.1222.01
CV (%)4.6%4.3%4.3%4.9%6%4.3%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of CXCL3/GRO gamma/CINC-2/DCIP-1 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 135403734362.296.3%
Sample 220522422419721211.845.5%
Sample 348946945650247917.733.7%
*number of samples for each test n=16.

Gene/Protein Information For CXCL3 (Source: Uniprot.Org, NCBI)

Gene Name

CXCL3

Full Name

C-X-C motif chemokine 3

Weight

10686 MW

Superfamily

intercrine alpha (chemokine CxC) family

Alternative Names

C-X-C motif chemokine 3;Dendritic cell inflammatory protein 1 ;Cxcl3 ;Dcip1 , Gm1960 ; CXCL3 CINC-2b, GRO3, GROg, MIP-2b, MIP2B, SCYB3 C-X-C motif chemokine ligand 3 C-X-C motif chemokine 3|GRO-gamma|GRO-gamma(1-73)|GRO3 oncogene|MGSA gamma|MIP2-beta|chemokine (C-X-C motif) ligand 3|growth-regulated protein gamma|macrophage inflammatory protein 2-beta|melanoma growth stimulatory activity gamma

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on CXCL3, check out the CXCL3 Infographic

CXCL3 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for CXCL3: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK1364 has been cited in 4 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

In vivo inhibition of miR-155 significantly alters post-stroke inflammatory response

CXCL3 overexpression promotes the tumorigenic potential of uterine cervical cancer cells via the MAPK/ERK pathway

Qi YL,Li Y,Man XX,Sui HY,Zhao XL,Zhang PX,Qu XS,Zhang H,Wang BX,Li J,Qi SF,Jia LL,Luan HY,Zhang CB,Wang WQ.CXCL3 overexpression promotes the tumorigenic potential of uterine cervical cancer cells via the MAPK/ERK pathway.J Cell Physiol.2020 May;235(5):475
Species: Human,Mouse
EK1364 usage in article: APP:ELISA, SAMPLE:HELA CELL AND WPMY‐1 CELL, DILUTION:NA

In vivo inhibition of miR-155 significantly alters post-stroke inflammatory response

Have you used Mouse CXCL3 / GRO gamma ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Mouse CXCL3 / GRO gamma ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

9 Customer Q&As for Mouse CXCL3 / GRO gamma ELISA Kit PicoKine®

Question

Does EK1364 contain native human biological materials?

Verified customer

Asked: 2021-11-10

Answer

The Mouse CXCL3 / GRO Gamma ELISA Kit PicoKine® (EK1364) doesn't contain native human biological materials. doesn't contain native human biological materials.

Boster Scientific Support

Answered: 2021-11-11

Question

Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for measurement CXCL3 using the EK1364 Mouse CXCL3 Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2020-12-13

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample immediately after collection when possible, or aliquot into single use volumes and store samples frozen. avoid repetitive freeze-thaw cycles with the stored samples in order to limit protein degradation.

Boster Scientific Support

Answered: 2020-12-13

Question

Q: what is the protocol regarding preparation of cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2020-12-11

Answer

A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate can be found in the product insert. Components in lysate and lysis buffer can effect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2020-12-11

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

C. Wu

Verified customer

Asked: 2020-02-12

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2020-02-12

Question

Q: if the enzyme conjugated CXCL3 antibodies are mixed with the substrate, will that convert the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the CXCL3 antigen?

Verified Customer

Verified customer

Asked: 2020-01-14

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2020-01-14

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2018-11-01

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2018-11-01

Question

Q: is it okay to use citrate plasma as samples in Mouse CXCL3 Picokine® ELISA Kit (Catalog # EK1364)?

Verified Customer

Verified customer

Asked: 2018-05-24

Answer

A: Chelating agents such as EDTA, Heparin and Citrate can irreversibly bind metal ions from the functional domain of CXCL3 causing disruption of its protein structure. CXCL3 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes a must for detection and block the antigen antibody reaction. We have tested the CXCL3 ELISA, treating samples with a number of anticoagulants and decided that heparin or EDTA can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.

Boster Scientific Support

Answered: 2018-05-24

Question

Q: Can CXCL3 ELISA Kits be used with tissue homogenates (or other non-validated sample types)?

Verified Customer

Verified customer

Asked: 2018-05-19

Answer

A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been assessd by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please see the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.

Boster Scientific Support

Answered: 2018-05-19

Question

Q: What is the optimal O.D. value for CXCL3 ELISA kit? I performed your CXCL3 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain CXCL3 even though the O.D. values are not very high?

L. Johnson

Verified customer

Asked: 2017-08-11

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. a point of focus should be is whether your sample O.D. values are statistically significantly higher than your blank values. regarding your protocol, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this CXCL3 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of CXCL3 that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2017-08-11

$499
In stock, 2 left.

Order within 0 hours and -18 minutes to receive by Fri Nov 22

Get A Quote
In stock
Order Product
EK1364
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.