Human Hemojuvelin/RGM-C/HJV ELISA Kit PicoKine®

Hjv ELISA kit for Human

Human Hemojuvelin/RGM-C/HJV ELISA Kit PicoKine™ (96 Tests). Quantitate Human HJV in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 15pg/ml.

Product Info Summary

SKU: EK1369
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Product Name

Human Hemojuvelin/RGM-C/HJV ELISA Kit PicoKine®

View all Hjv ELISA kits

SKU/Catalog Number

EK1369

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human Hemojuvelin/RGM-C/HJV ELISA Kit PicoKine™ (96 Tests). Quantitate Human HJV in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 15pg/ml.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Human Hemojuvelin/RGM-C/HJV ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1369)

Clonality of Antibodies

See Datasheet for details

Immunogen

Expression system for standard: NS0; Immunogen sequence: Q36-D400

Sensitivity

<15 pg/ml

Assay Range

156 pg/ml - 10,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

Add 100ul of sample diluent in well #2-#8. Add 200ul standard stock solution to well #1, and serial dilute for well #2-#7 to make a standard curve row. Leave well #8 as blank See datasheet of EK1369 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1369 is reactive to Hjv in Human samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

EK1369 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of Hjv

Hemojuvelin (HJV/RGMc/HFE2) is a membrane-bound and soluble protein in mammals. It is a member of the repulsive guidance molecule family of proteins. In humans, the hemojuvelin protein is encoded by the HFE2 gene. The product of this gene is involved in iron metabolism. It may be a component of the signaling pathway which activates hepcidin or it may act as a modulator of hepcidin expression. It could also represent the cellular receptor for hepcidin. Two uORFs in the 5' UTR negatively regulate the expression and activity of the encoded protein. Alternatively spliced transcript variants encoding different isoforms have been identified for this gene. Defects in this gene are the cause of hemochromatosis type 2A, also called juvenile hemochromatosis (JH). JH is an early-onset autosomal recessive disorder due to severe iron overload resulting in hypogonadotrophic hypogonadism, hepatic fibrosis or cirrhosis and cardiomyopathy, occurring typically before age of 30.

Kit Components

Catalog Number Description Quantity
EK1369-CAP Anti-Human Hjv Pre-coated 96-well strip microplate 1
EK1369-ST Human Hjv Standard 2 vials, 10 ng/tube
EK1369-DA Human Hjv Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015631262512502500500010000
O.D.0.1020.2330.1920.2840.4820.7731.2661.981

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect Hjv, Dilution ratio of 1:1, concentration in serum and plasma is 0-400 pg/ml..

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human Hemojuvelin/RGM-C/HJV ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)28511395792112311235755
Standard deviation17.3872.89457.5618.4574.11552.48
CV (%)6.1%6.4%7.9%6.6%6.6%9.6%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of Hjv in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 128529231928629513.824.6%
Sample 21139124712121220120439.973.3%
Sample 357926174525960985830359.736.1%
*number of samples for each test n=16.

Gene/Protein Information For Hjv (Source: Uniprot.Org, NCBI)

Gene Name

Hjv

Full Name

Hemojuvelin

Weight

45080 MW

Superfamily

repulsive guidance molecule (RGM) family

Alternative Names

Hemojuvelin Hjv|2310035L15Rik, 5230400G09Rik, AI414844, AI789733, DL-, DL-M, HJ, Hfe2, Rgm, Rgmc, hemoju, hemojuvelin|hemojuvelin BMP co-receptor|hemojuvelin|RGM domain family member C|hemochromatosis type 2 (juvenile) (human homolog)|hemochromatosis type 2 protein homolog|hemojuvelin BMP coreceptor|repulsive guidance molecule C

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on Hjv, check out the Hjv Infographic

Hjv infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for Hjv: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for EK1369

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Human Hemojuvelin/RGM-C/HJV ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Human Hemojuvelin/RGM-C/HJV ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

5 Customer Q&As for Human Hemojuvelin/RGM-C/HJV ELISA Kit PicoKine®

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

H. Evans

Verified customer

Asked: 2019-09-25

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2019-09-25

Question

Q: how many samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2019-03-26

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may depends upon the kit used so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2019-03-26

Question

Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for measuring HFE2 using the EK1369 Human HFE2 Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2019-03-17

Answer

A: Boster Bio does not assess sample stability. Variations in sample collection, processing, and storage may change the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples to avoid protein degradation.

Boster Scientific Support

Answered: 2019-03-17

Question

Q: What is the optimal O.D. value for HFE2 ELISA kit? I used your HFE2 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain HFE2 even though the O.D. values are not very high?

W. Mehta

Verified customer

Asked: 2018-01-21

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. a point of focus should be is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in proportion to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this HFE2 ELISA kit to have sensitivity of 15pg/ml, that means the minimum amount of HFE2 that can be declared/interpreted as positive by the above standard is 15pg/ml.

Boster Scientific Support

Answered: 2018-01-21

Question

Q: how to analyze ELISA data? I measured HFE2 level in cell lysates.

Y. Harris

Verified customer

Asked: 2016-07-10

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. we also provide a convenient online tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2016-07-10

$499
In stock, 3+ left.

Order within 16 hours and 24 minutes to receive by Fri Jul 5

Get A Quote
In stock
Order Product
EK1369
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.