Human CD44 PicoKine® Quick ELISA Kit

CD44 ELISA kit, 90-minute one-step protocol

Human CD44 PicoKine® Quick ELISA Kit (90 minues, 96 Tests). Quantitate Human CD44 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10 pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Product Info Summary

SKU: FEK1418
Size: 96 wells/kit, with removable strips.
Reactive Species: Human
Application: ELISA
Sample Types: cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).
Assay Time: 90 Minutes

How Quick Picokine(R) ELISA kits work: Get data in 90 minutes

how-elisa-kits-work

Product Name

Human CD44 PicoKine® Quick ELISA Kit

See all CD44 products

SKU/Catalog Number

FEK1418

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Human CD44 PicoKine® Quick ELISA Kit (90 minues, 96 Tests). Quantitate Human CD44 in cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10 pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months. (Ships with gel ice, can store for up to 3 days in room temperature. Refrigerate upon receipt.)

Cite This Product

Human CD44 PicoKine® Quick ELISA Kit (Boster Biological Technology, Pleasanton CA, USA, Catalog # FEK1418)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: NS0; Immunogen sequence: Gln21-Pro220

Sensitivity

<10 pg/ml

Assay Range

156 pg/ml - 10,000 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of FEK1418 for more details

Cross Reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

FEK1418 is reactive to CD44 in Human samples

Validated Sample Types

cell culture supernatants, cell lysates, serum and plasma (heparin, EDTA).

Application Guarantee

FEK1418 is guaranteed for ELISA in Human by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of CD44

CD44 is an integral cell membrane glycoprotein with a postulated role in matrix adhesion lymphocyte activation and lymph node homing. It is contains 19 exons spanning 50 kb of genomic DNA. In humans, the CD44 antigen is encoded by the CD44 gene on Chromosome 11. The protein encoded by this gene is a cell-surface glycoprotein involved in cell-cell interactions, cell adhesion and migration. It is a receptor for hyaluronic acid (HA) and can also interact with other ligands, such as osteopontin, collagens, and matrix metalloproteinases (MMPs). Transcripts for this gene undergo complex alternative splicing that results in many functionally distinct isoforms, however, the full length nature of some of these variants has not been determined. Alternative splicing is the basis for the structural and functional diversity of this protein, and may be related to tumor metastasis.

Kit Components

Catalog numberDescription QuantityVolume
FEK1418-CAPAnti-tag Pre-coated 96-well Strip Microplate 112 strips of 8 wells
EK1418-STHuman CD44 Standard 2 50 ng/tube
FEK1418-AHuman CD44 Antibody A 1 3ml
FEK1418-BHuman CD44 Antibody B 1 3ml
AR1106-1Sample Diluent 1 15ml
AR1106-7TBS-T Wash Buffer (25x) 1 12ml
AR1104Color Developing Reagent (TMB) 1 10ml
AR1105Stop Solution 1 10ml
PLA-SEAAdhesive Plate Sealers 2 Piece

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Automated plate washer (optional)
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.
  • Horizontal orbital microplate shaker capable of maintaining a speed of 500 rpm, amplitude 3mm.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)015631262512502500500010000
O.D.0.0510.1010.1340.2430.4390.8291.4822.072

Data Example Images

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Human CD44 PicoKine® Quick ELISA Kit within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)236102133641876563242
Standard deviation1672.18226.49.2633.98226.29
CV (%)6.8%7.1%6.7%5%5.2%7%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of CD44 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 123621717728823014.966.5%
Sample 21021739113972590666.57.3%
Sample 333644572362927663583138.653.9%
*number of samples for each test n=16.

Gene/Protein Information For CD44 (Source: Uniprot.Org, NCBI)

Gene Name

CD44

Full Name

CD44 antigen

Weight

81.538kDa

Alternative Names

CD44 antigen; CD44 molecule (Indian blood group); CD44; CD44R; CDw44; cell surface glycoprotein CD44; chondroitin sulfate proteoglycan 8; CSPG8; ECMR-III; epican; Extracellular matrix receptor III; GP90 lymphocyte homing/adhesion receptor; HCAM; HCELL; hematopoietic cell E- and L-selectin ligand; Heparan sulfate proteoglycan; Hermes antigen; homing function and Indian blood group system; HUTCH-I; Hyaluronate receptor; IN; LHR; MC56; MDU2; MDU2CD44 antigen (homing function and Indian blood group system); MDU3; MDU3CDW44; MIC4; MIC4MGC10468; MUTCH-I; Pgp1; PGP-1; PGP-I; Phagocytic glycoprotein 1 CD44 CDW44, CSPG8, ECMR-III, HCELL, HUTCH-I, IN, LHR, MC56, MDU2, MDU3, MIC4, Pgp1 CD44 molecule (Indian blood group) CD44 |GP90 lymphocyte homing/adhesion receptor|Hermes |Indian blood group |cell surface glycoprotein CD44|chondroitin sulfate proteoglycan 8|epican|extracellular matrix receptor III|hematopoietic cell E- and L-selectin ligand|heparan sulfate proteoglycan|homing function and Indian blood group system|hyaluronate receptor|phagocytic glycoprotein 1|soluble CD44

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on CD44, check out the CD44 Infographic

CD44 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for CD44: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

No publications found for FEK1418

*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.

Have you used Human CD44 PicoKine® Quick ELISA Kit?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Human CD44 PicoKine® Quick ELISA Kit

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

0 Customer Q&As for Human CD44 PicoKine® Quick ELISA Kit

$499
Backordered.

Lead time for this item is typically 2-3 weeks

Get A Quote
In stock