Product Info Summary
SKU: | EK2156 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Human |
Application: | ELISA |
Sample Types: | cell culture supernatants, serum and plasma (heparin, EDTA) |
Product info
Product Name
Human CD302 ELISA Kit PicoKine®
View all CD302/CLEC13A ELISA kits
SKU/Catalog Number
EK2156
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human CD302 ELISA Kit PicoKine® (96 Tests). Quantitate Human CD302 in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 10 pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human CD302 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK2156)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: HEK293; Immunogen sequence: D23-N167
Sensitivity
<10 pg/ml
Assay Range
15.6 pg/ml - 1,000 pg/ml
Standard Dilution Instructions
See datasheet of EK2156 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK2156 is reactive to CD302 in Human samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin, EDTA)
Application Guarantee
EK2156 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of CD302/CLEC13A
The CD302 antigen also known as C-type lectin domain family 13 member A is a protein that in humans is encoded by the CD302 gene. CD302 is a C-type lectin receptor involved in cell adhesion and migration, as well as endocytosis and phagocytosis.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK2156-CAP | Anti-Human CD302 Pre-coated 96-well strip microplate | 1 |
EK2156-ST | Human CD302 Standard | 2 vials, 10 ng/tube |
EK2156-DA | Human CD302 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration(pg/ml) | 0 | 15.6 | 31.2 | 62.5 | 125 | 250 | 500 | 1,000 |
O.D. | 0.023 | 0.081 | 0.142 | 0.289 | 0.544 | 0.823 | 1.697 | 2.014 |
Data Example Images
Click image to see more details
Human CD302 PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect CD302/CLEC13A, Dilution ratio of 1:1, concentration in serum and plasma is around 100 pg/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human CD302 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean(pg/ml) | 136 | 252 | 548 | 147 | 274 | 559 |
Standard deviation | 5.98 | 13.1 | 18.08 | 7.2 | 16.71 | 30.19 |
CV(%) | 4.4% | 5.2% | 3.3% | 4.9% | 6.1% | 5.4% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of CD302/CLEC13A in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 136 | 142 | 133 | 129 | 135 | 6.62 | 4.9% |
Sample 2 | 252 | 258 | 261 | 274 | 261 | 9.41 | 3.6% |
Sample 3 | 548 | 569 | 582 | 603 | 576 | 18.42 | 3.2% |
Protein Target Info & Infographic
Gene/Protein Information For CD302 (Source: Uniprot.Org, NCBI)
Gene Name
CD302
Full Name
CD302 antigen
Weight
26.183kDa
Alternative Names
BIMLEC; CD302 antigenC-type lectin domain family 13, member A; CD302 molecule; CD302; CLEC13A; CLEC13AMGC22301; C-type lectin domain family 13 member A; DCL1; DCL-1; DCL1C-type lectin BIMLEC; KIAA0022FLJ43091; Type I transmembrane C-type lectin receptor DCL-1 CD302 BIMLEC, CLEC13A, DCL-1, DCL1 CD302 molecule CD302 |C-type lectin domain family 13, member A|DEC205-associated C-type lectin 1|type I transmembrane C-type lectin receptor DCL-1
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on CD302, check out the CD302 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for CD302: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Human CD302 ELISA Kit PicoKine® (EK2156)
Loading publications
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Human CD302 ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Human CD302 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question