Product Info Summary
SKU: | EK0681 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Human |
Application: | ELISA |
Sample Types: | cell culture supernatants, serum and plasma (heparin, EDTA, citrate) and urine. |
Product info
Product Name
Human CA2 / Carbonic Anhydrase 2 ELISA Kit PicoKine®
View all Carbonic Anhydrase II/CA2 ELISA kits
SKU/Catalog Number
EK0681
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human CA2 / Carbonic Anhydrase 2 ELISA Kit PicoKine® (96 Tests). Quantitate Human CA2 in cell culture supernatants, serum and plasma (heparin, EDTA, citrate) and urine. Sensitivity: 50pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human CA2 / Carbonic Anhydrase 2 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK0681)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: E.coli; Immunogen sequence: S2-K260
Sensitivity
<50 pg/ml
Assay Range
0.78 ng/ml - 50 ng/ml
Standard Dilution Instructions
See datasheet of EK0681 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK0681 is reactive to CA2 in Human samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin, EDTA, citrate) and urine.
Application Guarantee
EK0681 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of Carbonic Anhydrase II/CA2
CA2 is a cytosolic enzyme with the highest activity among all known CAs. The carbonic anhydrases (ACs) form a family of enzymes that catalyze the rapid interconversion of carbon dioxide and water to bicarbonate and protons (or vice versa), a reversible reaction that occurs relatively slowly in the absence of a catalyst. Mutations in the CA2 gene result in the CA II deficiency syndrome, an autosomal recessive disorder that produces osteopetrosis, renal tubular acidosis and cerebral calcification. This gene is mapped to 8q22.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK0681-CAP | Anti-Human CA2 Pre-coated 96-well strip microplate | 1 |
EK0681-ST | Human CA2 Standard | 2 vials, 50 ng/tube |
EK0681-DA | Human CA2 Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (ng/ml) | 0 | 0.78 | 1.56 | 3.12 | 6.25 | 12.5 | 25 | 50 |
O.D. | 0.068 | 0.126 | 0.207 | 0.344 | 0.588 | 1.047 | 1.942 | 2.157 |
Data Example Images
Click image to see more details
Human CA2 PicoKine ELISA Kitstandard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect Carbonic Anhydrase II/CA2, Dilution ratio of 1:10, concentration in serum and plasma is 15-76 ng/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human CA2 / Carbonic Anhydrase 2 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 1174 | 5107 | 21947 | 1365 | 6165 | 23984 |
Standard deviation | 48.13 | 214.49 | 987.62 | 64.16 | 332.91 | 1367.09 |
CV (%) | 4.1% | 4.2% | 4.5% | 4.7% | 5.4% | 5.7% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of Carbonic Anhydrase II/CA2 in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 1174 | 1071 | 1108 | 1106 | 1114 | 37.23 | 3.3% |
Sample 2 | 5107 | 5193 | 4515 | 4791 | 4901 | 268.69 | 5.4% |
Sample 3 | 21947 | 21460 | 19663 | 20115 | 20796 | 937.16 | 4.5% |
Protein Target Info & Infographic
Gene/Protein Information For CA2 (Source: Uniprot.Org, NCBI)
Gene Name
CA2
Full Name
Carbonic anhydrase 2
Weight
29.246kDa
Superfamily
alpha-carbonic anhydrase family
Alternative Names
Carbonic anhydrase 2; Carbonate dehydratase II; Carbonic anhydrase C; CAC; Carbonic anhydrase II; CA-II; CA2 CA2 CA-II, CAC, CAII, Car2, HEL-76, HEL-S-282 carbonic anhydrase 2 carbonic anhydrase 2|carbonate dehydratase II|carbonic anhydrase B|carbonic anhydrase C|carbonic anhydrase II|carbonic dehydratase|epididymis luminal protein 76|epididymis secretory protein Li 282
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on CA2, check out the CA2 Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for CA2: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Human CA2 / Carbonic Anhydrase 2 ELISA Kit PicoKine® (EK0681)
Hello CJ!
EK0681 has been cited in 1 publications:
*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.
Transcription factor Tbx18 induces the differentiation of c-kit canine mesenchymal stem cells (cMSCs) into SAN-like pacemaker cells in a co-culture model in %u2026
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Human CA2 / Carbonic Anhydrase 2 ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Human CA2 / Carbonic Anhydrase 2 ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
6 Customer Q&As for Human CA2 / Carbonic Anhydrase 2 ELISA Kit PicoKine®
Question
Q: if the enzyme conjugated CA2 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the CA2 antigen?
Verified Customer
Verified customer
Asked: 2020-08-18
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2020-08-18
Question
Q: is there any online tool I can use to streamline the data analysis for my ELISA results?
Verified Customer
Verified customer
Asked: 2020-08-11
Answer
A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions
Boster Scientific Support
Answered: 2020-08-11
Question
Q: how to proceed with the analysis of ELISA data? I have performed CA2 level in serum.
Verified Customer
Verified customer
Asked: 2019-10-06
Answer
A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. we also provide a convenient online tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online
Boster Scientific Support
Answered: 2019-10-06
Question
Q: can you suggest the dilution ratio of serum samples for detection of CA2 in Human serum? I am trying to measure a multiple analytes and it requires 100ul of diluted samples for each well. We have limited sample quantitys so we like to dilute as much as possible.
Verified Customer
Verified customer
Asked: 2019-02-20
Answer
A: unable to know the physiological or pathological context of your samples we cannot recommend a dilution ratio without performing a pilot test with your samples. Here is how you can perform a pilot study on your own: perform a serial dilution of your samples on the CA2 ELISA kit to make sure you have a linear ascending curve followed by a plateau, which signifies the samples saturating the detection limit of the kit. Then you can pick the dilution ratios from samples in the linear part of the curve as your experimental dilution ratio.
If you are interested in using our ELISA service, you can also send us your sample and we will take care of everything for you. You can check our service details here: bosterbio.com/services/assay-services/ELISA-testing-service
Since you mentioned you have limited samples, our cost effective multiplex ELISA service would fit perfectly for your needs, where we can generate dozens of data points using as little as 25ul sample volume. Information on this service is also in the above link.
Boster Scientific Support
Answered: 2019-02-20
Question
Q: What is the optimal O.D. value for CA2 ELISA kit? I performed your CA2 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. can I consider these samples contain CA2 even though the O.D. values are not very high?
K. Huang
Verified customer
Asked: 2018-12-06
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. a point of focus should be is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this CA2 ELISA kit to have sensitivity of 50pg/ml, that means the minimum amount of CA2 that can be declared/interpreted as positive by the above standard is 50pg/ml.
Boster Scientific Support
Answered: 2018-12-06
Question
Q: is it okay to use citrate plasma as samples in Human CA2 Picokine® ELISA Kit (Catalog # EK0681)?
Verified Customer
Verified customer
Asked: 2018-11-26
Answer
A: Chelating agents such as EDTA, Heparin and Citrate can bind metal ions from the functional domain of CA2 causing degradation of its protein structure. CA2 may be denatured as a result and may compromise the assay's measurements. The chilating sites could also be too close to the epitopes required for detection and block the antigen antibody reaction. We have tested the CA2 ELISA, treating samples with various anticoagulants and decided that heparin, EDTA or citrate can be used for treatment of blood/plasma samples. Do not use other anticoagulents when collecting samples.
Boster Scientific Support
Answered: 2018-11-26