Rat IL-3 ELISA Kit PicoKine®

IL-3 ELISA kit for Rat

Rat IL-3 ELISA Kit PicoKine® (96 Tests). Quantitate Rat Il3 in cell culture supernatants and serum. Sensitivity: 2pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays. Cited in 2 publication(s).

Product Info Summary

SKU: EK1324
Size: 96 wells/kit, with removable strips.
Reactive Species: Rat
Application: ELISA
Sample Types: cell culture supernatants and serum.

Product Name

Rat IL-3 ELISA Kit PicoKine®

View all IL-3 ELISA kits

SKU/Catalog Number

EK1324

Size

96 wells/kit, with removable strips.

*Question: How many samples can I assay/run in this kit?

Description

Rat IL-3 ELISA Kit PicoKine® (96 Tests). Quantitate Rat Il3 in cell culture supernatants and serum. Sensitivity: 2pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.

Storage & Handling

Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Cite This Product

Rat IL-3 ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1324)

Clonality of Antibodies

See Datasheet for details

Standard Protein

Expression system for standard: E.coli; Immunogen sequence: I27-C169

Sensitivity

<2 pg/ml

Assay Range

7.8 pg/ml - 500 pg/ml

Standard Dilution Instructions

serial dilution instructions image

See datasheet of EK1324 for more details

Cross-reactivity

There is no detectable cross-reactivity with other relevant proteins.

Reactive Species

EK1324 is reactive to Il3 in Rat samples

Validated Sample Types

cell culture supernatants and serum.

Application Guarantee

EK1324 is guaranteed for ELISA in Rat by Boster Guarantee

See how Boster Bio validate our ELISA kits: ELISA Validation Information

Background of IL-3

The gene IL-3 encodes interleukin 3, a hematopoietic colony-stimulating factor (CSF) that is capable of supporting the proliferation of a broad range of hematopoietic cell types. Interleukin-3 (IL-3), a protein of 140 amino acids, is chemically synthesized by means of an automated peptide synthesizer and is shown to have the biological activities attributed to native IL-3. The cDNA sequence for murine interleukin-3, one of the colony stimulating factors that regulate haematopoiesis, codes for a polypeptide of 166 amino acids including a putative signal peptide. The mouse IL 3 gene is located on chromosome 11. The human gene encoding IL 3 is tandemly arrayed on the long arm of chromosome 5.5 The standard product used in this kit is recombinant human IL-3, consisting of 133 amino acids with the molecular mass of 15KDa.

Kit Components

Catalog Number Description Quantity
EK1324-CAP Anti-Rat Il3 Pre-coated 96-well strip microplate 1
EK1324-ST Rat Il3 Standard 2 vials, 10 ng/tube
EK1324-DA Rat Il3 Biotinylated antibody (100x) 100ul
AR1103 Avidin-Biotin-Peroxidase Complex (100x) 100ul
AR1106-1 Sample Diluent 30ml
AR1106-2 Antibody Diluent 12ml
AR1106-3 Avidin-Biotin-Peroxidase Diluent 12ml
AR1104 Color Developing Reagent (TMB) 10ml
AR1105 Stop Solution 10ml
AR1106-5 Wash Buffer (25x) 20ml
PLA-SEA Adhesive plate sealers 4

*The kit components are not available for individual purchase.

Materials Required But Not Included In Kit

  • Microplate Reader capable of reading absorbance at 450nm.
  • Incubator.
  • Automated plate washer (optional).
  • Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
  • Multichannel pipettes are recommended for large amount of samples.
  • Deionized or distilled water.
  • 500ml graduated cylinders.
  • Test tubes for dilution.

Validation Standard Curve O.D. At 450nm

Concentration (pg/ml)07.815.631.362.5125250500
O.D.0.0110.0590.0960.1840.2990.7671.4782.267

Data Example Images

Recommended Sample Dilution Ratios

According to our internal validation assays using this ELISA kit, to detect IL-3, Dilution ratio of 1:1, concentration in serum is less than the lowest standard, 7.8 pg/ml..

Some articles we found to cite concentrations of IL-3 in samples: 22583131 (Pubmed IDs).

Intra Assay Consistency & Inter Assay Consistency

We measured random samples of Rat IL-3 ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.

Intra-Assay PrecisionInter-Assay Precision
Sample123123
n161616242424
Mean (pg/ml)16912561484249
Standard deviation0.85.3616.640.775.3717.43
CV (%)5%6.5%%6.5%5.5%6.4%7%

Reproducibility

We ensure reproducibility by testing three samples with differing concentrations of IL-3 in ELISA kits from four different production batches/lots.

LotsLot 1 (pg/ml)Lot 2 (pg/ml)Lot 3 (pg/ml)Lot 4 (pg/ml)Mean (pg/ml)Standard DeviationCV (%)
Sample 116151515150.432.8%
Sample 291908599915.015.5%
Sample 32562432302372419.553.9%
*number of samples for each test n=16.

Gene/Protein Information For Il3 (Source: Uniprot.Org, NCBI)

Gene Name

Il3

Full Name

Interleukin-3

Weight

18631 MW

Superfamily

IL-3 family

Alternative Names

Interleukin-3;IL-3;Hematopoietic growth factor;Mast cell growth factor;MCGF;Multipotential colony-stimulating factor;P-cell-stimulating factor;Il3;Il-3; IL3 IL-3, MCGF, MULTI-CSF interleukin 3 interleukin-3|P-cell stimulating factor|colony-stimulating factor, multiple|hematopoietic growth factor|mast-cell growth factor|multilineage-colony-stimulating factor|multipotential colony-stimulating factor

*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".

For more info on Il3, check out the Il3 Infographic

Il3 infographic

We have 30,000+ of these available, one for each gene! check them out.

In this infographic you will see the following information for Il3: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].

Hello CJ!

EK1324 has been cited in 2 publications:

*The publications in this section are manually curated by our staff scientists. They may differ from Bioz's machine gathered results. Both are accurate. If you find a publication citing this product but is missing from this list, please let us know we will issue you a thank-you coupon.

Wu Z, Ming Y, Zhang Z, Wu J, Wu Z, Yao S. Chin Med J (Engl). 2014;127(5):968-70. Edaravone Rescues The Lung By Inhibiting Lipid Peroxidation And Pro-Inflammatory Cytokines In A Rat Model.

Guida F, Luongo L, Aviello G, Palazzo E, De Chiaro M, Gatta L, Boccella S, Marabese I, Zjawiony Jk, Capasso R, Izzo Aa, De Novellis V, Maione S. Mol Pain. 2012 Aug 23;8:60. Doi: 10.1186/1744-8069-8-60. Salvinorin A Reduces Mechanical Allodynia And...

Have you used Rat IL-3 ELISA Kit PicoKine®?

Submit a review and receive an Amazon gift card.

  • $30 for a review with an image

0 Reviews For Rat IL-3 ELISA Kit PicoKine®

Have a question?

Find answers in Q&As, reviews.

Can't find your answer?

Submit your question

9 Customer Q&As for Rat IL-3 ELISA Kit PicoKine®

Question

Q: can you tell me how to prepare cell lysates prepared for use in Picokine® ELISA kits?

Verified Customer

Verified customer

Asked: 2020-12-05

Answer

A: in those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are present in the product insert. Components in lysate and lysis buffer can affect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.

Boster Scientific Support

Answered: 2020-12-05

Question

Q: Are Boster Bio recombinant proteins and antibodies sterile?

Z. Puri

Verified customer

Asked: 2020-02-28

Answer

A: although the vials are bottled using aseptic techniques, heat-treated vials, and sterile stock solutions, they are not considered or guaranteed to be sterile. If sterile material is required for an experiment, the material can be filtered through a 0.2 micron filter designed for use with biological fluids.

Boster Scientific Support

Answered: 2020-02-28

Question

Q: if the enzyme conjugated IL-3 antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the IL-3 antigen?

Verified Customer

Verified customer

Asked: 2019-07-30

Answer

A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.

Boster Scientific Support

Answered: 2019-07-30

Question

Q: What is the optimal O.D. value for IL-3 ELISA kit? I used your IL-3 ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain IL-3 even though the O.D. values are not very high?

C. Puri

Verified customer

Asked: 2019-03-29

Answer

A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. what you should focus on is whether your sample O.D. values are statistically significantly higher than your blank values. in your example, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. typically, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by changeing cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this IL-3 ELISA kit to have sensitivity of 10pg/ml, that means the minimum amount of IL-3 that can be declared/interpreted as positive by the above standard is 10pg/ml.

Boster Scientific Support

Answered: 2019-03-29

Question

Q: how can I thaw whole blood sample for IL-3 ELISA after freezing?

Verified Customer

Verified customer

Asked: 2019-02-15

Answer

A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test IL-3 for a later time, you should let the blood clot in glass tubes and collect the serum to freeze for later use.

Boster Scientific Support

Answered: 2019-02-15

Question

Q: for how much duration can samples (cell cultures, serum, and plasma) be stored and still be stable for quantification IL-3 using the EK1324 Rat IL-3 Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2018-10-12

Answer

A: Boster Bio does not evaluate sample stability. Variations in sample collection, processing, and storage may affect the stabilityof samples. It is recommend to assay sample right after collection when possible, or aliquot into single use volumes and store samples frozen. limit repetitive freeze-thaw cycles with the stored samples to prevent protein degradation.

Boster Scientific Support

Answered: 2018-10-12

Question

Q: how much samples can be assayed in a Picokine® ELISA Kit?

Verified Customer

Verified customer

Asked: 2018-08-02

Answer

A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may vary slightly by kit so please refer to each datasheet for details.

Boster Scientific Support

Answered: 2018-08-02

Question

Q: is there any online tool I can use to streamline the data analysis for my ELISA results?

Verified Customer

Verified customer

Asked: 2018-04-27

Answer

A: We have a web based ELISA curve fitting (4pl) and data analysis tool. Please give it a try: bosterbio.com/biology-research-tools/ELISA-data-analysis-online. You can also consult our article on ELISA data analysis: bosterbio.com/ELISA-data-analysis-instructions

Boster Scientific Support

Answered: 2018-04-27

Question

Q: how to analyze ELISA data? I measured IL-3 level in serum.

C. Bhatt

Verified customer

Asked: 2014-02-16

Answer

A: please read this article on ELISA data analysis. bosterbio.com/ELISA-data-analysis-instructions. Boster also provides a free tool that you can use to analyze ELISA data. bosterbio.com/biology-research-tools/ELISA-data-analysis-online

Boster Scientific Support

Answered: 2014-02-16

$499
In stock, 3+ left.

Order within 0 hours and -24 minutes to receive by Fri Nov 22

Get A Quote
In stock
Order Product
EK1324
$499.00

Troubleshooting

troubleshooting-box-image

Download troubleshooting handbooks for IHC, Western blot and ELISA for FREE.

Download Free PDFs Now

Boster Guarantee

Guaranteed product quality

Guaranteed product quality

We promise all of our products perform as described in datasheets.