Product Info Summary
SKU: | EK1845 |
---|---|
Size: | 96 wells/kit, with removable strips. |
Reactive Species: | Human |
Application: | ELISA |
Sample Types: | cell culture supernatants, serum and plasma (heparin, EDTA). |
Product info
Product Name
Human MANF ELISA Kit PicoKine®
SKU/Catalog Number
EK1845
Size
96 wells/kit, with removable strips.
*Question: How many samples can I assay/run in this kit?
Description
Human MANF ELISA Kit PicoKine® (96 Tests). Quantitate Human MANF in cell culture supernatants, serum and plasma (heparin, EDTA). Sensitivity: 15 pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Storage & Handling
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Cite This Product
Human MANF ELISA Kit PicoKine® (Boster Biological Technology, Pleasanton CA, USA, Catalog # EK1845)
Clonality of Antibodies
See Datasheet for details
Standard Protein
Expression system for standard: NS0; Immunogen sequence: L25-L182
Sensitivity
<15 pg/ml
Assay Range
93.6 pg/ml - 6,000 pg/ml
Standard Dilution Instructions
See datasheet of EK1845 for more details
Cross-reactivity
There is no detectable cross-reactivity with other relevant proteins.
Reactive Species
EK1845 is reactive to MANF in Human samples
Validated Sample Types
cell culture supernatants, serum and plasma (heparin, EDTA).
Application Guarantee
EK1845 is guaranteed for ELISA in Human by Boster Guarantee
See how Boster Bio validate our ELISA kits: ELISA Validation Information
Background of MANF
MANF is a 20kDa protein which belongs to the ARMET family. This gene is mapped to 3p21.2. MANF was originally known as an arginine-rich region protein which was extremely mutated in a large number of tumors. MANF Expression is induced during ER stress, signifying that MANF takes part in protein quality control during ER stress.
Kit Components
Catalog Number | Description | Quantity |
---|---|---|
EK1845-CAP | Anti-Human MANF Pre-coated 96-well strip microplate | 1 |
EK1845-ST | Human MANF Standard | 2 vials, 10 ng/tube |
EK1845-DA | Human MANF Biotinylated antibody (100x) | 100ul |
AR1103 | Avidin-Biotin-Peroxidase Complex (100x) | 100ul |
AR1106-1 | Sample Diluent | 30ml |
AR1106-2 | Antibody Diluent | 12ml |
AR1106-3 | Avidin-Biotin-Peroxidase Diluent | 12ml |
AR1104 | Color Developing Reagent (TMB) | 10ml |
AR1105 | Stop Solution | 10ml |
AR1106-5 | Wash Buffer (25x) | 20ml |
PLA-SEA | Adhesive plate sealers | 4 |
*The kit components are not available for individual purchase.
Materials Required But Not Included In Kit
- Microplate Reader capable of reading absorbance at 450nm.
- Incubator.
- Automated plate washer (optional).
- Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
- Multichannel pipettes are recommended for large amount of samples.
- Deionized or distilled water.
- 500ml graduated cylinders.
- Test tubes for dilution.
Data Examples, Quality Control Data & Sample Dilution
Validation Standard Curve O.D. At 450nm
Concentration (pg/ml) | 0 | 93.8 | 187.5 | 375 | 750 | 1500 | 3000 | 6000 |
O.D. | 0.063 | 0.091 | 0.109 | 0.171 | 0.354 | 0.654 | 1.194 | 1.885 |
Data Example Images
Click image to see more details
Human MANF PicoKine ELISA Kit standard curve
Recommended Sample Dilution Ratios
According to our internal validation assays using this ELISA kit, to detect MANF, Dilution ratio of 1:5, concentration in serum and plasma is around 8 ng/ml..
Intra Assay Consistency & Inter Assay Consistency
We measured random samples of Human MANF ELISA Kit PicoKine® within the same batch/lot to ensure the consistency of the kits' performances. ELISA intra assay consistency is measured using wells from the same plate/assay kit. ELISA inter assay consistency is measured using wells from different plates from the same batch production/lot.
Intra-Assay Precision | Inter-Assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 16 | 16 | 16 | 24 | 24 | 24 |
Mean (pg/ml) | 156 | 733 | 2725 | 166 | 748 | 2871 |
Standard deviation | 9.67 | 47.65 | 125.35 | 8.47 | 55.35 | 195.23 |
CV (%) | 6.2% | 6.5% | 4.6% | 5.1% | 7.4% | 6.8% |
Reproducibility
We ensure reproducibility by testing three samples with differing concentrations of MANF in ELISA kits from four different production batches/lots.
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%) |
---|---|---|---|---|---|---|---|
Sample 1 | 156 | 148 | 167 | 169 | 160 | 8.51 | 5.3% |
Sample 2 | 733 | 654 | 771 | 713 | 717 | 42.29 | 5.8% |
Sample 3 | 2725 | 2678 | 2428 | 2740 | 2642 | 126.07 | 4.7% |
Protein Target Info & Infographic
Gene/Protein Information For MANF (Source: Uniprot.Org, NCBI)
Gene Name
MANF
Full Name
Mesencephalic astrocyte-derived neurotrophic factor
Weight
20.7kDa
Superfamily
ARMET family
Alternative Names
Mesencephalic astrocyte-derived neurotrophic factor; Arginine-rich protein; Protein ARMET; MANF; ARMET; ARP MANF ARMET, ARP mesencephalic astrocyte derived neurotrophic factor mesencephalic astrocyte-derived neurotrophic factor|arginine-rich, mutated in early stage tumors
*if product is indicated to react with multiple species, protein info is based on the gene entry specified above in "species".For more info on MANF, check out the MANF Infographic
We have 30,000+ of these available, one for each gene! check them out.
In this infographic you will see the following information for MANF: database IDs, super-family, protein function, synonyms, molecular weight, chromosomal locations, tissues of expression, subcellular locations, post translational modifications, and related diseases, research areas & pathways. If you want to see more information included, or would like to contribute to it and be acknowledged, please contact us [email protected].
Specific Publications For Human MANF ELISA Kit PicoKine® (EK1845)
Hello CJ!
No publications found for EK1845
*Do you have publications using this product? Share with us and receive a reward. Ask us for more details.
Recommended Resources
Here are featured tools and databases that you might find useful.
- Boster's Pathways Library
- Protein Databases
- Bioscience Research Protocol Resources
- Data Processing & Analysis Software
- Photo Editing Software
- Scientific Literature Resources
- Research Paper Management Tools
- Molecular Biology Software
- Primer Design Tools
- Bioinformatics Tools
- Phylogenetic Tree Analysis
Customer Reviews
Have you used Human MANF ELISA Kit PicoKine®?
Submit a review and receive an Amazon gift card.
- $30 for a review with an image
0 Reviews For Human MANF ELISA Kit PicoKine®
Customer Q&As
Have a question?
Find answers in Q&As, reviews.
Can't find your answer?
Submit your question
6 Customer Q&As for Human MANF ELISA Kit PicoKine®
Question
Q: which procedure should I follow in order to thaw whole blood sample for MANF ELISA after freezing?
Verified Customer
Verified customer
Asked: 2020-07-25
Answer
A: do not freeze and thaw whole blood. erythrocytes are fragile and, if frozen and thawed, will undergo hemolysis rendering the samples useless. To keep your blood samples to test MANF for a later time, you should let the blood clot in glass tubes and collect the serum to freeze for later use.
Boster Scientific Support
Answered: 2020-07-25
Question
Q: how are cell lysates prepared for use in Picokine® ELISA kits?
H. Maharaj
Verified customer
Asked: 2020-01-24
Answer
A: for those Picokine® ELISAs where cell or tissue lysate is a validated sample type, sample preparation instructions for lysate are included in the product insert. Components in lysate and lysis buffer can effect immunoreactivity, so if lysate is not a validated sample type, care must be taken in sample preparation and validation.
Boster Scientific Support
Answered: 2020-01-24
Question
Q: Can MANF ELISA Kits be used with tissue homogenates (or other non-validated sample types)?
Verified Customer
Verified customer
Asked: 2018-10-18
Answer
A: Unfortunately, Boster Bio has not routinely validated tissue homogenates as a sample type for ELISA kits. This does not mean that ELISA kits are not suitable for other sample types than we have tested: it means further investigation is required. One will need to perform a spike and recovery study to determine if an unvalidated sample type will work with a particular kit. To perform a spike and recovery experiment, one should divide a sample into two aliquots. In one of the aliquots, the user should spike in a known amount of the kit standard. a dilution series is performed comparing the spiked versus the unspiked sample. Generally, samples with expected recovery and linearity between 80-120% are considered acceptable. This method can be used to validate any sample type that has not been evaluated by Boster Bio. for a more detailed spike and recovery protocol, please contact technical support.
Note: acceptable ranges should be determined individually by each laboratory. Additionally, technical support can help determine if a buffer component is not compatible with a given ELISA kit. please check the Citations tab on the product webpage for peer-reviewed papers utilizing a wide range of sample types. We also have an innovator's reward program where if the user validates our ELISA kits in applications or samples previously not validated by Boster Bio or other users, and share such information with us by submit a review, we will reward the user's efforts with a free antibody or ELISA kit from our catalog. Biocompare.com will also give $20 Amazon giftcard as an additional reward, if the review is submitted there as well.
Boster Scientific Support
Answered: 2018-10-18
Question
Q: if the enzyme conjugated MANF antibodies are mixed with the substrate, will that change the substrate into the enzymatic reaction product? Or the enzyme function is only activated when the antibody is attached with the MANF antigen?
P. Puri
Verified customer
Asked: 2017-11-25
Answer
A: The enzyme is always active. Avoid contaminating the substrate with enzyme prior to the incubation otherwise it compromises the assay with false positive signal.
Boster Scientific Support
Answered: 2017-11-25
Question
Q: What is the optimal O.D. value for MANF ELISA kit? I performed your MANF ELISA on serum samples. For my positive control, I received an O.D. value of 0.826, while my negative control received a value of 0.136. I obtained both of these controls from the ELISA kit, where your kit's typical data shows O.D. values much higher than my positive control and your background is lower. My samples O.D. values are around 0.225 and the highest is only 0.357. is it safe to say these samples contain MANF even though the O.D. values are not very high?
Verified Customer
Verified customer
Asked: 2015-09-12
Answer
A: The absolute O.D. values may change according to incubation time. The more you incubate the higher the O.D. values are going to be. an important assessment should be is whether your sample O.D. values are statistically significantly higher than your blank values. in the example mentioned, you could extend your development time in the substrate incubation step to obtain higher O.D. values, as long as your negative controls' O.D. values are not increasing faster in relation to your positive controls. normally, a sample with O.D. value 2 standard deviations higher than your negative controls can be considered positive. We calculate the sensitivity of this ELISA kit by converting cutoff O.D. value, calculated as the average of 20 negative controls plus 2 standard deviations of the 20 negative controls, into a concentration. in other words, when we claim this MANF ELISA kit to have sensitivity of 15pg/ml, that means the minimum amount of MANF that can be declared/interpreted as positive by the above standard is 15pg/ml.
Boster Scientific Support
Answered: 2015-09-12
Question
Q: how many samples can be assayed in a Picokine® ELISA Kit?
S. Collins
Verified customer
Asked: 2015-02-06
Answer
A: The Picokine® ELISA Kits will generally run a 7-point standard curve, non-specific binding wells, and 39 samples in duplicate. this may might differ by kit so please refer to each datasheet for details.
Boster Scientific Support
Answered: 2015-02-06